ML19256F389

From kanterella
Jump to navigation Jump to search
Forwards Safety Evaluation Re Potential for Water Hammer in Feedwater Piping
ML19256F389
Person / Time
Site: Fort Calhoun 
Issue date: 12/03/1979
From: Lainas G
Office of Nuclear Reactor Regulation
To: Reid R
Office of Nuclear Reactor Regulation
Shared Package
ML19256F390 List:
References
NUDOCS 7912190069
Download: ML19256F389 (2)


Text

E [f "%,,

,o, UNITED STATES i

NUCLEAR REGULATORY COMMISSION

s. <

{ - -

,i wAsm NGTON, D. C. 20555

/

DEC 3 573 5,,,

s, MEMORANDUM FOR:

R. Reid, Chief, Operating Reactors Brcnch #4, DOR FROM:

G. Lainas, Chief, Plant Systems Branch, DDR

SUBJECT:

STEAM GENERATOR WATER HAMMER Plant Name:

Fort Calhoun Station, Unit No. 1 Docket No.: 50-285 Responsible Branch: ORB #4 Project Manager:

P. Erickson Reviewing Branch:

Plant Systems Branch Review Status: Compl ete In response to Technical Assistance Request, TAC Number 7254, regarding water hammer in the Fort Calhoun feedwater systems, the Plant Systems Branch has completed its review and found that acceptable precautions are being taken to minimize the occurrence of water hammer in the feedwater piping. The basis for our conclusions are provided in the enclosed Safety Evaluation Report.

This completes our review of steam generator water hamer under TAC 7254.

G. Lainas, Chief Plant Systems Branch Division of Operating Reactors

Enclosure:

As stated

Contact:

S. MacKay X-27111 cc w/ enclosure:

See page 2 1625 103

  • N ma

, DEC 3 1979 cc w/ enclosure:

D. Eisenhut B. Grires S. Hanauer E. Adensam W. Gamili E. Reeves P. Erickson S. MacKay V. Noonan J. Huang 1625 104

.