ML19256F181

From kanterella
Jump to navigation Jump to search
Notification of 791120 Meeting W/Util,Westinghouse,Wi Public Svc Commission & Wi Environ Decade-UCS to Discuss Steam Generator Tube Degradation & Recent Insp Results
ML19256F181
Person / Time
Site: Point Beach 
Issue date: 11/16/1979
From: Trammell C
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 7911210581
Download: ML19256F181 (2)


Text

pa asc,q'o e

UNITED STATES E }* g( [,,g NUCLEAR REGULATORY COMMISSION E

WASHINGTON, D. C. 20555

'%; %?,o$

November 16, 1979 Docket No. 50-266 MEMORANDUM FOR:

A. Schwencer, Chief Operating Reactors Branch #1, 00R FROM:

Charles M. Trammell, Project Ma~ nager Operating Reactors Branch #1, D0R

SUBJECT:

FORTHCOMING MEETING WITH WISCONSIN ELECTRIC POWER COMPANY TO DISCL'SS STEAM GENERATOR TUBE DEGRADATION AND RECENT INSPECTION RESULTS AT POINT BEACH UNIT NO. 1 Date:

Tuesday, November 20, 1979 Time and Place: 9:00 am Phillips Building Room P-500

Participants:

NRC H. Denton A. Schwencer K. Parczewski E. Case V. Noonan G. Knighton D. Eisenhut R. Tedesco W. Pasedag W. Gammill B. Grimes C. Trammell B. D. Liaw E. Murphy J. Strosnider Wisconsin Electric Power Westinghouse D. Porter R. Begl ey R. Newton T. Esselman C. W. Fay T. Anderson G. Frieling S. Burstein Wisconsin Public Service Comm. Wisconsin's Environmental L. Smith Decade - Union of Concerned Scientists R. Pollard ddd

/Mme Charles Trammell, Project Manager Operating Reactors Branch #1 Division of Operating Reactors cc:

See next page 13/7 516 7 9112105F /

1

rieeting Notice for Point Beach 1 November 16, 1979 Docket Files NRC PDR Local PDR ORB 1 Reading NRR Reading H. Denton E. Case D. Eisenhut R. Tedesco B. Grimes R. Vollmer J. Miller

~

L. Shao W. Gammill G. Zech A. Schwencer D. Ziemann P. Check G. Lainas D. Crutchfield B. Grimes T. J. Carter T. Ippolito R. Reid V. Noonan G. Knighton D. Brinkman P. T. Kuo Project Manager OELD OSD (3)

S. Showe, I&E C. Parrish/P. Kreutzer H. Fraley, ACRS (16)

TERA J. R. Buchanan Principal Staff Participants Receptionist, Bethesda l'rogram Support Branch f ),

ij7

,