N ON o
~
Babcock &Wilcox S
po e, ceo.,,,,,o o,oo, e
RECEIVEP
_g Barberton, Ohio 44203 C
NOV 011979 5 Teienenea2 tensa.4 sit
$~
L7g
- u. s. m w T
October 29, 1979
. l,P WO)
Y U
O k
&Q'
'N U
...,%s;1979. a /
8*
Mr. Jack Spraul U.S. IAtelear Regulatory Co= mission g
. ' ' S.g
" f O
Transportation Branch re Division of Fuel Cycle & Material Safety DISS 9
Washington, D.C. 20555
Reference:
Your letter FCTR: EHO 71-0079 My letter dated Oct. lo,1979, same subject.
Subject:
QA Program For Use of Shipping Packages Rev. 1 dated October 26, 1979
Dear Sir:
In accordance with ce==itments provided in 7 letter of October lo,1979 and our subsequent telephone conversations the week of October 22,1979, I as submitting the above subject revised (Rev.1) CA Program for your approval. Seven (7) copies are attached hereto.
Appropriate changes have been made to satisfy the request for additional infor:ation as indicated in your above referenced letter. Specific revisions are indicated as follows:
Para. 1.3 has been revised to include naces and titles of individuals responsible for radiographer certification and test status.
Para. 3.3 has been revised to include names and titles of individuals responsible to insure all QA functions are conducted in accordance with applicable dccuments.
Para. h.2 provides a state =ent that shipments will not be =ade unless all tests, certifications, acceptances and final inspections are complete.
Para. 5.h has been revised to include na=es and titles of individuals responsible to perform the regulatory required inspections and tests and individual responsiMe to assure these functions are performed.
Pars. 6.1.8 has been added to include raintenance of " procure: rent, I *,)
, h -[
)
docu=en s".
7 911210 ON The Babcock & Wilcox Company ! Established 1867
(
s Mr. Jack Spraul October 29, 1979 Para. 7.2 has been added to include a statenent "Each quality related activity will be audited at least once each year by an auditor (or audit team) having no responsibility in the activity being audited".
General Organizational charts have been revised to reflect current organizational structure.
Very truly yours, s
H. C. Graber Barberton Works Radiation Safety Officer attach.
13/b 288 i'
1613
s PART IV TABLE OF CONTENTS i
I Administrative Procedure Number Subject Revision l
1 QA PROGRAM FOR USE OF SHIPPING PACKAGES 1
i b,)
f f
1 h
[