ML19256E807
| ML19256E807 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry |
| Issue date: | 11/07/1979 |
| From: | Mills L TENNESSEE VALLEY AUTHORITY |
| To: | Ippolito T Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 7911150272 | |
| Download: ML19256E807 (2) | |
Text
-
TENNESSEE V ALLEY AUTHCR!TY
- ,. ~ s. e, ;.
r s m ; -: t 3 u:
400 Chestnut Street Tower II November 7, 1979 Director of Nuclear Reactor Regulation Attention:
Mr. Thomas A. Ippolito, Chief 3 ranch No. 3 Division of Operating Reactors U.S. Nuclear Regulatory Commission liashington, DC 20555
Dear Mr. Ippolito:
In the Matter of the
)
Docket Nos. 50-259 Tennessee Valley Authority
)
50-260 50-296 This is in response to your letter dated August 28, 1979, to H. G. Parris concerning pending amendment requests for Browns Ferry Nuclear Plant.
A priority list is enclosed which provides your staff the guidance necessary to evaluate the relative importance of each pending amendment request to TVA.
If you have any further questions, please get in touch with us.
Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Enclosure
.r 1338 282 f ool 7911150 N 5lll F
m :=
=
~
BROWNS FERRY UNITS 1, 2, AND 3 PENDING AMENDMENT REQUESTS Request No.
Priority Subj ect Date Submitted TVA BFNP TS 127 1*
Unit 3 Reload for Cycle 3 3/6/79 TVA BFNP TS 128 2**
Reactor Vessel Bolt-up 8/6/79 Temperature TVA BFNP TS 90 3
Lottled-up Operatior.
8/5/77 TVA BFNP TS 107 4
~
TVA BFNP TS 77 5
ASME, Inservice Inspection 1/28/77 TVA BFNP TS 89 6
Inservice Inspection Unit 3 7/29/77 TVA BENP TS 125 7
Units 1 & 2 - Pump L Valve Testing 7/20/79 TVA BFNP TS 80 8
161-kV line out & licensed 3,21/77 Operator TVA BFNP TS 93 9
Fire Protection 9/23/77 partial approval 1/10/78 TVA BENP TS 122 10 Miscellaneous cleanup changes 3/1/79 TVA BFNP TS 101 11 NSRB Qualifications 3/3/78 TVA BFNP TS 74 12 RHRSW 12/6/76 TVA BFNP TS 92 13 Valve lineup changes 8/23/77 acended 5/12/78 TVA BFNP TS 124 14 Appendix I 7/20/79 TVA BFNP TS 123 15 Miscellaneous cleanup changes 6/29/79 (18 total)
TVA BFNP TS 120 16 SCTS & RAD control 1/10/79 TVA BFNP TS 113 N/A SGIS and valve lineup 8/3/78 TVA BENP TS 126 N/A Count Rate Requirements for 7/20/79 SRM's
- Need approval by November 15, 1979
- Need approval as soon as possible 1338 283