ML19256E598
| ML19256E598 | |
| Person / Time | |
|---|---|
| Site: | University of Missouri-Columbia |
| Issue date: | 10/05/1979 |
| From: | Davis A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Brugger R MISSOURI, UNIV. OF, COLUMBIA, MO |
| Shared Package | |
| ML19256E599 | List: |
| References | |
| NUDOCS 7911080123 | |
| Download: ML19256E598 (2) | |
See also: IR 05000186/1979006
Text
'
an neo
+
o
UNITED STATES
8
NUCLEAR REGULATORY COMMISSION
,.,
g
g
,a
REGION 111
%,.....,#[
799 ROOSEVELT ROAD
0,
GLEN ELLYN. ILLINOIS 60137
OCT
5 1979
Docket No. 50-186
University of Missouri
ATTN: Dr. Robert M. Brugger
Director
Research P.eactor
Facility
Research Park
Columbia, MO 65201
Gentlemen:
This refers to the inspection conducted by Mr. J. W. Hiatt of this office
on September 1?-13, 1979, of activities at the University of Missouri
Research Reactor authorized by NRC Operating License No. R-103 and to the
discussion of our findings with Mr. Alger and other members of the facility
staff at the conclusion of the inspection.
The enclosed copy of our inspection report
ientifies areas examined
during the inspection. Within these areas, si.c inspection consisted of a
selective examination of procedures and represen?.ative records, observations,
independent measurements and interviets with persennel.
During this inspection, certain oC your activities appeared to ue in
noncompliance vfth NRC requiremests, as described in the enclosed
Appendix A.
This notice is sent to you pursuut to the provisions of Section 2.201 of
the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.
Section 2.201 requires you to srbmit to this office within twenty days of
your receipt of this notice a written statement or explanation in reply,
including for each item of noncompliance: (1) corrective action taken and
the results achieved; (2) corrective action to be taken to avoid further
noncompliance; and (3) the date when full compliance will be achieved.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,
Title 10, Code of Federal Regulations, a copy of this letter, the enclosures,
and your respcase to this letter will be placed in the NRC's Public
Document Room, except as follows.
If the enclosures contain information
that you or your contractors t,elieve to be proprietary, you must apply in
writing to this office, within twenty days of your receipt of this letter,
,
L
1294
308
7911080123
.
t
,
University of Missouri
-2-
OCT
5 1979
to withhold such information from public disclosure. The application
must include a full statement of the reasons for which the information is
considered proprietary, and should be prepared so that proprietary
information identified in the application is contained in an enclosure to
the application.
We will gladly discuss any questions you have concerning this inspection.
Sincerely,
,
b
'
6
. B. Davis, Chief
Fuel Facility and Materials
Safety Branch
Enclosures:
1.
Appendix A, Notice
of Violation
2.
IE Inspection Report
No. 50-186/79-06
cc w/encls:
Central Files
Reproduction Unit NRC 20b
1294
309
,
.