AUG 311979 APPENDIX A NOTICE OF VIOLATION General Electric Company License No. SNM-1097 Wilmington Nuclear Fuel Plant Based on the NRC inspection August 13-16, 1979, certain of your activities were apparently not conducted in full compliance with NRC requirements as indicated below. These items have been categorized as described in correspondence to you dated December 31, 1974.
As required by Condition 14 of license SNM-1097, materials and equipment released from restricted areas shall meet the contamination limits of Annex C.
Annex C specifies the limits for the release of material from restricted areas as a maximum amount of fixed alpha radioactivity of 25,000 disintegrations per minute per 100 square centimeters and the average amount should not exceed 5,000 disinte-grations per minute per 100 square centimeters.
Contrary to the above, on or about August 7,1979, material was removed from the site restricted areas which was contaminated to levels in excess of the limits of Annex C to SNM-1097. The highest maximum level was 30,700 disintegrations per minute per 100 square centimeters and the highest average level was 14,800 disintegrations per minute per 100 square centimeters of fixed alpha radioactivity.
This is an infraction.
[3 }9 i'
630 79110 20 ig -
.