ML19256E229

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 5910,Revision 2,for Radioactive Matl Shipping Package Model NNFD-SA-2
ML19256E229
Person / Time
Site: 07105910
Issue date: 10/15/1979
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19256E227 List:
References
NUDOCS 7910300346
Download: ML19256E229 (2)


Text

-

Form NRC418 U.S. NUCLEAR REGULATORY COMLISSION U

CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radioactive Materials Packages 1.f a) Certificate Number 1.(b) Revision No.

1.(c) Package Identification No.

1.(d) Pages No. 1.(e) Total No. Pages 5910 2

USA /5910/B(

)F 1

2

2. PRE AMBLE 2.(a)

This certificate is issued to satisf y Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146--19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.lb)

The packaging and conte nts 1escribed in item 5 below, meets the safety sundards set forth in Subpart C of Title 10, Code of

. Federal Regulations, Par

  • 71, " Packaging of Radioactive Materials for Tra, sport and Transportation of Radioactive Material Under Certain Conditions."

2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or cther applicable regulatory agencies, including the government of any country througn or into which the packase will be transported.

3. This certificate is issued on the basis of a safety analysis rep 3rt of the package oesign or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

The Babcock & Wilcox Company The Babcock & Wilcox Company application dated P.O. Box 785 March 6, 1970, as supplemented Lynchburg, VA 24505 3.(c)

Docket No.

71-5910 4 CONDITIONS This certificate is concit onal upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions :pecified in item 5 Delow.

5. Description of Packaging a M Authorized Contents, Model Number, Fissile Class, Other Conditions, and

References:

(a) Pac'kaging (1) Model No.: NNFD-SA-2 (2) Description Fuel container is a 14 gage steel box with a maximum outside cross sectional area of 8.5 square inches, with gasketed lid closure.

Fuel container is supported in an open birdcage of slotted angle iron, with outside dimensions 2' x 2' x 12' maximum.

Container and birdcage are constructed in accordance with design shown in Appendix A, Figures 1 and 2, of Westinghouse Electric Corporation's application dated November 6,1967.

(b) Contents (1) Type and form of material Uranium enriched in the U-235 isotope to any enrichment, as sintered uranium oxide fuel e'ie.nents, clad with bonded zircaloy 2.

Element dimensions are approximately 0.090" x 3.5" x 96".

(2) Maximum quantity of material per package 12n,,

358 Total contents not to exceed 240 pounds, with U-235 not to exceed four (4) kilograms.

7910300

Page 2 - Certificate No. 5910 - Revision No. 2 - Docket No. 71-5910 5.

(c)

Fissile Class III Maximum number of packages per shipment Rine (9) 6.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

~

7.

Expiration date: October 31, 1984.

REFERENCES The Babcock & Wilcox Company application dated March 6,1970.

Westinghouse Electric Corporation's application dated November 6,1967.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION b

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety 1 5 1979 Da te:

1221 359

_