{{#Wiki_filter:*' 1 $b

  • d h'f t

RMC-TR-77-01 ~ ?.S8 C:cht# h,'1'd diedF'pgOf: CC*l ? i.' DatL- ^~ ggijlAI0a1'=?nl. RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT For The THREE MILE ISLAND NUCLEAR STATION 1976 ANNUAL REPORT JANUARY 1 THROUGH DECEMBER 31 Prepared for METROPOLITAN EDISON COMPANY l448 .)75 By RADIATION MANAGEMENT CORPORATION MARCH 1977 4mrh .o

y / RMC-TR-77-01 RADIOLOGICAL ENVIRONMENTAL MONITURING RE? ORT For he THREE MILE ISLAND NUCLEAR STATION T 1976 ANNUAL REPORT JANUARY 1 THROUGH DECEMBER 31 5 l' r f P Prepared for METROPOLITAN EDISON COMPANY BY l RADIATION MANAGEMENT CORo0 RATION l l MARCH 1977 I i 1448 .)76 m-

s TABLE OF CONTEN'S PAGE LIST OF FIGURES ii LIST OF TABLES 11

SUMMARY

1 INTRODUCTION 3 PROGRAM 4 Objectivet 4 Design 4 Exceptions 5 RESULTS AND DISC.SSION 5 Aquatic Errironment 10 Atmospher : Environment 12 Terrestria Environment 15 Direct Rac ation 15 ASSESSMENT OF Il:ACT 17 CONCLUSIONS 19 REFERENCES 20 APPENDIX A Sampl ng Locations 23 APPENDIX B INDE) 33 APPENDIX B Data Tables 81-B21 35-64 i 4 I I ~ 1448 077 1 i i, t N .e. =

=, ' I LIST OF FIGURES PAGE 1. AVERAGE TRITIUM CONCENTRATIO.lS IN THE SUSQUEHANNA 11 RIVER IN THE VICINITY OF TMINS 2. AVERAGE GRCSS BETA CONCENTRATIONS IN AIRBORNE 13 PARTICULATES IN THE VICINITY OF THINS 16 1 3. AVERAGE GAMMA COSE RATES IN THE VICINITY OF TMINS LIST OF TABLES 1. SYNOPSIS OF THE OPERATIONAL RADIOLOGICAL ENVIRONMENTAL 6 MONITORING PROGRAM FOR TMINS ~ 2.

SUMMARY

OF RADIONUCLIDE CONCENTRATIONS IN ENVIRONMENTAL 7 SAMPLES FROM TMINS 9 3.

SUMMARY

OF DIRECT RADIATION MEASUREMENTS AT TMINS { h 4. 1976 ENVIRONMENTAL SAMPLE DATA WHICH RESULTED IN 18 l NON-ROUTINE REPORTING 2 d 3 s 1 .b 4 11 1448 )78

.a

SUMMARY

l During the period January 1 through Cecerter 31, 1976, Radiation Management Corporation (RIC) participated in the coerational radiological environmental nonitoring program (REMP) conducted by Metropolitan Edison Ccmpany at Three Mile Island Nuclear Station (TMINS). 3 I The RMC portion of this program uns designed to aid in meeting the obligations of the Environmental Technical Specifications (ETS) for TMINS Unit #1 (TMI-1) (1) and the Preoperational Requirements for TMINS Unit #2 (TMI-2). I A total of 1381 analyses were performed on 959 samoles during the period covered by this report. These samples were taken from the aquatic, atmosp! eric and terrestrial environments and included direct radiation measurements. I Additional samples and analyses beyond those required by the environmental technical specifications were performed as noted in the data tables of Appendix B. Surface water (6 locations, 72 samples) was an'alyzed for gama emitting nuclides while cuarterly ccaposites (24) were analyzed for H-3. Untreated drinking water (3 locations,12 samples) was anal:' red for H-3, Sr-89, Sr-90 and gama emitting nuclides. Fish (2 locations, 8 samples) and sediment - i (3 locations, 6 samples) were also taken from the aquatic anvironment and analyzed for Sr-89, Sr-90 and gama emitting nuclides. Ns aquatic plant samples were available during this period. The atmospheric environment sampling program included air particulates, air iodine, and precipitation. Air particulates (9 locations, 482 samples) were analyzed for gross beta activity and ganma emitting nuclides. Charcoal cartridges (4 locations, 206 samples) were analyzed for I-131. Precipitaticq, prinarily rain water, (4 locations, 48 samples) was analyzed for gross beta activity, H-3, Sr-89, Sr-90, and gama emitting nuclides. Milk (5 locations, 45 samples) was taken frem the terrestrial environment and analyzed for 1-131, Sr-89, Sr-90. Two goat's milk samples were ttken and analyzed for I-131. In accordance with environmental technical specifications, an update on the milking animal census was performed during this period. A distribution of 1082 milking ccws at 32 locations was detennined, an increase of 38 cows since Septemoer 1975. No dairy operations, closer to TMINS than those already being sampled, were found. Green leafy vegetables (4 locations, 4 samples), fruit (2 lccations, 4 samples), meat and game (4 locations, 4 samples), and alfalfa (2 locations, 2 samples) were taken and analyzed fu gama emitting nuclides. In addition, 312 analyses for imersien dose (21 locations, 78 packets) i using TLCs were made during this period. All radiol uclide concentrations were similar to those normally found in local I unaffected areas, except for those pathways exnibiting elevated activities due to the,hinese Nuclear Tes t of Septemaer 26, 1976, tritium activity in two surface water samples, and ganna activity in one sediment sample. i, 1448 079 1

The Chinese Nuclear Test resulted in elevated concentrations of radionuclide These increases can be distinguished from in many environmental patnways. those of TMINS operation since they effect both indicator and background locations equally. A dose to an infant's thyroid of 60 mrem can be attributed j to I-131 in milk as a result of these tests. I The H-3 concentration in surface water at a downstream indicator location (1.5 miles dcwnstream) showed an elevated level relative to the upstream samples twice during the reporting period. No increase in the H-3 levels at the downstream locations where river water is used as a drinking water source Therefore, no measurable dose can be attributed to the release was observed. of H-3 from TMINS, During October a variety of nuclides were detected in a sediment sample; Since these nuclides were not probably not the result of station operation. detected in surface water or fish, the only significant dose pathway would be from standing on the shoreline. A hignly conservative dose estir3te yields an insignificant dose to a hypothetical maximum individual of 0.33 mrem / year. It is therefore concluded that station operation did not produce any significant changes in the observed environmental levels of radioactivity. These temporary i changes noted in sediment could have resulted in an insignificant dose to a hypothetical maximum individual of 0.33 mrem. 1 4 1 .A 1 a 1448 J80

.. ~ - INTRODUCTION A complete radiological environmente. monitoring program (REMP) for Three Mile Island Nuclear Station (TMINS) has been conducted by Metropolitan Edison Company since June 1969. Radiation Management Corporation has participated in this program since February 21, 1974. Results of the preoperational phase of the REMP up to June 5,1974, and of the aperational phase (June 5, 1974 through December 31,1975) were reported in previous RMC s documents (2,3,4,5). This report continues the operational series with coverage of 1976. It presents in de: ail the type and number of samples analyzed, the analyses performed and the data generated by RMC during ) the period January 1 through Cecember 31, 1976. Interpretation of tne data and conclusions are also presented. Three Mile Island is the site of an coerational nuclear power unit of the pressurized water reactor (PWR) type. When complete the station will i consist of two reactor units. Unit 1, rated at 371 MWe, achieved criticality on June 5, 1974 This marked the beginning of the operational phase of the REMP. Unit 2, rated at 959 MWe, is under construction and scheduled } for cocmercial operation in 1978. } The station is located on Three Mile Island in the Susouehanna River, in Dauphin County, ten miles southeast of Harrisburg, Pennsylvania. The average flow of tne river at this point is 34,000 cfs(6). The site consists of an 814 acre tract on Three Mile Island and several smaller i adjacent islands. General climatic conditions are characterized by a mild continental-type climate with little severe weather. Agriculture j is the largest land usage in the area (48%), with the emphasis on poultry, dairy cattle and field crops (7). The census of milking cows located within five miles of TMINS(7) was updated 3 in the previous semi-annual report (5) and again during this report period. 5 The distribution and approximate locations of these animals are given in Table B-21 (Appendix B). I More specific information on the demography, meteorology and land use characteristics of local area may be found in the Environmental i { Report (8) Environmental Statement (9), Final Safety Analysis Report for y TMI-2(10), and the Environmental Report Supplement II(11). i I f 1448 081 T 3 h

. ~. - - - i PROGRAM ) i In the operational phase of the REMP, radicanalytical data are collected Di fferences for comparison to that generated in the preoperational phase. between these two periods are examined statistically to determine whether I any station effects exist based on the magnitude and fluctuations of l radioactivity levels determined in the preoperational phase. Objectives The objectives of the operational radiological environmental program are: To fulfill the obligations of the Radiological Surveillance-1. Environmental sections of the Environmental Technical Specifications for TMI-1 and the Preoperational Program for TMI-2. To determine whether any statistic. iy significant increase 2. occurs in the concentration of radionuclides in critical pathways. 3. To detect any buildup of long-lived radionuclides in the environment. i 4. To detect any change in ambient gama radiation levels. 5. To verify that radioactive releases are within allcwable limits and that TMI-1 coerations nave no detrimental effects on the health ano safety of the pu5 Tic or on tne environment. This report provides information for the Metropolitan Edison Company, General Public Utilities, regulatory agencies and the public record toward these 3 objectives. Oesign In order to meet the stated objectives, an appropriate operational REMP was developed by RMC in cooperation with Metrocolitan Edison Company. Samples for the operational REMP were taken from the aquatic, atmospheric, and terrestrial environments. Samples of various mecia were selected to obtain data for the evaluation of the radiation dose to man and important organisms. Sample types were based on (1) established critical pathways for ~ the transfer of radionuclides througn the environment to man, and (2) experience gained during the preoperational and initial operational phases. Samoling locations were determined from site meteorology, Susquehanna River hydrology, local demography and land uses. Samoling locations were divided into two classes--indir.ator and control. Indicator stations are tnose wnich are expected to manifest station effects, if any exist; control samples are collected at locations wnich are believed to a Fluctuations in the levels of radionuclides be unaffected by station operatwns. and direct radiation at indicator stations are evaluated with respect to analogous fluctuations at control stations, wnicn are unrelated to station operation. Indicator station data are also evaluated relative to background characteristics est:blished prior to station operation. Additional sacoles beyond those required by ne Environmental Tecnnical Scecifications were collected and analy:ed; They are listed as Metropolitan Edison Ccepany manacement audit samoles in tne data tacles (4pendix 3). 1448 08?

The analysis of samples and the analytical data generated during the program are routinely evaluated by the RMC project leader who is the liaison with Metropolitan Edison Comoany personnel. Further review of RE.NP design and analytical dati is performed by RMC and Metropolitan Edison Company professional staff in light of current regulatory trends and operating experience. The analytical procedures and quality control methods utilized by RMC are detailed in Reference 12. Table 1 sumarizes information on the Three Mile Island Nuclear Station operational REMP as performed by RMC. Appendix A explains the RMC sample coding system which specifies sample type and relative locations at a glance. Table A-1 gives the pertinent information on individual sampling locations, while Maps A-1, -2 and -3 show their geographic locations. i Exceptions The operational REMP was conducted in accordance with the Environmental Technical Specifications for TMI-1(1) and the preccerational Program for TMI-2. Deviations from the program as described in Tacle 3 of these specifications t occurred during this ceriod. Because aquatic plants are very scarce in the i vicinity of TMINS, none were available for sampiing during this report period. Milk samples were taken during those months when milk cows were on pasture, (March througn Novemoer). The farm from wnich background milk samples were obtained (IF2) went out of buisness in March. This farm was replaced in i April with location 2Gl. Pumo outages resulted in the loss of 14 air particulate samples and 2 air iodine samples at various stations. Air sample recovery e rate was greater than 97*.'. RESULTS AND DISCUSSION I The averages and ranges of analytical results are sumarized in Tables 2 and i 3. Table 2 is a sumary of gross beta, H-3, Sr-89, Sr-90, I-131 and gamma spectrometric results for various samples. Table 3 is a sumary of amoient radiation levels as measured by thermoluminescent dosimeters. Results for each type of sample were grouced accorcing to tne analysis performed. Means and standard deviations of these results were calculated wnen applicable. These standard deviations represent sacole population variability ratner than analytical variability. For this calculation, al' results below the MDL were considered to be at tne MCL. Comoarisons of TLD results were made using T ter.ts for unequal observations and unequal variations as described by Stcal a Torrie (13). The data for individual samples are presented in tabular form in Acpendix B. Tables 8-1 through B-19. Within the data tables a 95t (: 2 sigma) confidence interval is supolied. These intervals represent the range of values into which 95". of receated analyses of the samole would fall. All nimum detectacle level were results occurring at or below tne relevant i reported as being "lew than" the MCL value. 1448 J83 s

L TABLE 1 SYNOPSIS OF Tile OPERATIONAL RADIOLOGICAL ENVIRONMENTAL HONITORING PROGRAM FOR TM JANUARY 1 TilROUGil DECENUER 31, 1976 ANALYSIS SAMPLE SANPLING TYPE TkTQFDTCY Le~CAYi~0}IS NUlMER T(PE FliEQUENCY NUl%Ili Surface Water / HC 6 72 31-3 QC 24 Ganna HC 72 Drinking Water Sr-89 QC 12 Sr-90 QC 12 Fish SA 2 8 Sr-89 SA 8 Sr-90 SA 8 Ganna SA 8 Sediment SA 3 6 Sr-89 SA 6 Sr-90 SA 6 Ganna SA 6 Air Particulates W 9 482 Deta W 482 Ganna MC 24 Air Iodine W 4 206 I-131 W 206 m Precipitation M 4 48 11-3 QC 16 Beta M 48 Sr-89 SA 8 Sr-90 SA 8 Gansna QC 16 Milk H 5 45 1-131 M 45 [ Sr-89 QC 20 i Sr-90 QC 20 t A Green Leafy A 4 4 Ganna A 4 4 Co vegetables frutts A 2 4 Ganna A 4 c Deef and Game A 4 4 Gansna A 4 Vegetation A 2 2 Guana A 2 Dosineters Q 21 78 Ganna Dose Q 312

_,.,,e,-....+ n,__ l TABLE 2 StkfiARY OF RADIONUCLI0E CONCENTRATIONS IN ENVIRONMENTAL, SAMPLES TROM THINS JANUARY I THROUGi 11CIMIER 31, 1976 NO. OF N0. SAMPLE ANALYSIS 5AMFLES AB0VE AVERAGE PRE-OP TYPE PERFORMED ANALYZED MDL MINIMUM MAXIMUH

  • 2 SICHA HEAN UNITS Surface Water it-3 (Upstream) 8 8

106 40075 215:200 2401180 pCI/l H-2 (Downstream) 16 13 (80 886176 2512449 pCi/l $r-8s 12 1 0.410.3 <l.6 pCf/l Sr-90 12 6 <0.4 0.720.2 0.610.4 pCi/l Ganna

  • 72 pCl/l r.-40 3

(6.0 16t9 pC1/1 Zrth-95 2 <0.4 4.4t0.7 pCl/l Ra-226 7 <0.9 2.111.2 pCi/l Fish 5r-89 8 0 <l.7 (27 pCl/kg (wet) Sr-90 8 7 2.010.8 108:14 33181 45155 pCl/kg (wet) Ganina 8 K-40 8 2600:260 3200:320 28381512 3300:1700 pCi/kg (wet;l Zrth-95 1 <4.0 7.015.7 pCl/kg (wet,i Cs-137-2 <5.0 13t6 pct /kg (wet) Sediment Sr-89 6 3 4.3 3.7 34 6 17120 pC1/kg (dry) Sr-90 6 6 1415 7819 37247 3901450 pC1/kg (dry) Gonna 6 Be-7 4 <100 1200:200 5001910 9401690 pC1/kg (dry) K-40 6 1400011000 18000 2000 1550012757 1470016700 hi-54 1 <10 20:20

  • pCl/kg(dryl pC1/kg (dryj Co-58 1

(10 50:20 pCi/kg (dry,I 2r-95 3 (20 3100t300 61212449 791152 pCl/kg (dry) IL-95 3 (20 2400:200 462 1904 1761172 pC1/kg (dry) Ru-103 3 90:30 1200:100 460:1282 pC1/kg (dry 3 $b-125 1 (40 100!60 pCi/kg (dry) 1-131 1 <10 200:40 pC1/kg (dry'l Cs-137 6 230:40 480:50 345:173 430:290 p.1/kg (dr y'l Bata-140 1 <20 800t90 pC1/kg (dryl lA Cc-141 2 <20 2600t300 pCl/kg (dryj 4 Ra-226 6 11001100 1200:200 1116s82 1070:260 pCi/kg (dryl Th-232 6 400:200 1300 100 850 787 11101b00 pCi/kg (dry) g 3 Air Particulates Beta 482 <3 748t28 451185 146t164 10' pCi/m , Ce Gama 24 3 CO Be-7 24 4014 130t14 74153 46 27 10' pC1/m m ni-54 3 <0.05 0.4to.4 10' pCl/m 3 Co.58 4 <0.05 0.610.4 10~ pCf/m 3 Ir-95 7 <0.07 35 4 10 8 10' pC1/m 3 re-95 6 <0.07 20t3 21:17 10' pC1/m 3 Ru-103 6 (0.00 1912 1.4 0.8 10' pC6/m 3 Ru-106 1 <0.5 <3 20:18 10' pCi/m 3 1-131 2 <0.09 2.0t0.4 10' pCi/m 3 Cs-137 18 (0.1 3.4 1.2 0.711.'6 4.015.3 10' pCi/m I Data-140 4 <0.1 1111 10' pCi/m Cc-141 6 <0.1 3213 10' pCl/m l Ce-144 4 <0.7 1315 50:48 10' pC1/m 3 a

,1 _ w 4 TABLE 2 (Cont.) 5tt1HARY OF RADIONUCLIOC CONCENTRATIONS IN ENVIRONMENTAL 5A)FLES FROH THINS JANUAM 1 THROUQ1 DECEftLR 31. 1976 l I NO. OF NO. SAMPLE ANALY515 5AMPLES ABOVE AVERAGE PRE-OP l TYPE PERf0RMED ANALY2ED HDL HINIMJH MXIMUH 2 2 SIGMA MEAN litITS Air lodine I-131 206 4 <4 108:11 10~3pCl/m3 Precipitation H-3 16 15 <80 360 66 170titi6 370:170 pCl/l beta 48 41 <l.9 782 19 592293 22127 pct /l Sr-89 8 4 (0.6 7.7 0.8 2.314.8 pC1/1 $r-90 8 5 <0.4 1.1:0.4 0.710.5 5.119.0 pC1/1 Gonna 16 be-7 8 4.414.0 37:11 17:21 33:56 pCl/l C0-58 1 <0.3 3.010.9 pCl/l 2r-95 4 (0.4 63t6 pCl/l l Hb-95 4 <0.4 100:10 pC1/1 R:s-103 4 3.210.7 1212 pct /1 L-141 4 1.3s0.6 15e2 pct /l Ce-144 2 <l.0 52113 pC1/1 Ra-226 3 <0.6 3.2:1.3 pct /l M11L I-131 45 9 <0.04 4bt5 pCf/l Sr-89 20 1 <0.3 2.210.9 3Ct/] Sr-90 20 14 <0.3 5.6:2.2 1.913.2 4.917.1 pct /l Green Leafy Ganer.a 4 Vegetable K-40 4 20002200 3000:300 24001848 13800226800 pCl/kg fruits Ganna 4 K-40 4 10001100 2500:250 182511400 pC1/kg Beef Ganna 2 K-40 2 3300:330 3500 350 3400:283 16002200 pC1/'s Game Gansina 2 4 K-40 2 31001310 3100:310 3100:0 pct /kg Cs-137 1 <5 1517 10:14 pCl/kg 00 Vegetation Ganu 2 O be-7 2 7801410 850:390 815199 167012810 pC1/kg (dry) K-40 2 26000:2600 42000:420 34000:22600 13780126835 pCl/kg (dry) g All gansna emitters not listed tsere <MDL in all samples.

.o,,, 6 TABLE 3 SlftMRY OF OIRECT RA01All0N HEASUREMENTS AT ' MINS JANUARY I TilR0tGI DECLFLIER 31, 1916 i NO. OF 5AMPLING AVERAGE SAMPLE SAMPLES PERIOD HINIHUM MAIIHH 2 2 SIGMA UNITS CONTROL LOCATIONS Quarterly TLD 24 12-29-75 Duse n.ste to 5.75to.24 7.6210.60 6.4711.50 mre # standard month

  • 3-31-76 3-31-76 to 4.8010.30 7.05:0.45 5.7911.48 mre# standard month 6-30-76 6-30-76 to 5.0010.22 1.0310.14 5.64t1.42 mres/ standard month 9-29-76 9-29-16 to 5.3810.36 8.4910.25 6.83 2.09 mrea/ standard nionth 12-29-76 e

INDICATOR LOCATIONS Quarterly TLD $4 12-29-75 Dose Rate to 4.7210.19 6.3210.13 5.7012.27 mreWstandard mosth 3-31-76 3-31-76 to 3.9910.37 5.6610.36 4.98t0.98 mreW standard month 6-30-76 6-30-76 ^ to 3.9110.21 5.7010.54 4.9221.18 meeWstandard month 9-29-76 9-29-16 to 5.4610.53 6.9810.63 6.09:0.91 mreWstandard month 12-29-76 -Z> b \\ standard Hunth = 30.4 days. Q D l N i l

i l l I Aouatic Environment Surface Water i Monthly surface water samoles were collected at 6 locations on the dates l shown in Table B-1. 'Jeekly grab samoles from stations 1C3, 9A2 and 981 were taken and composited monthly. Samples from stations 8El,15F1 and 7G1 were taken on a semi-continuous basis and comoosited to monthly samples. Each sample was analyzed for gama emitting nuclides by RMC procecure TGC and quarterly composites from each station were analyzed for H-3 by RMC procedure Samples from SEl,15F1 and 7G1 (drinking water treatment facilities) were HXH. The results therefr;m are included in this also analyzed for Sr-89 and Sr-90. report. Results of H-3 analyses are presented in Table B-2 and Figure 1. Concen-trations of H-3 were observed to be sligntly higher than normal during first and third quarters at one indicator station. No increase was observed at this time at station 7G1 (Columoia) or SE1 (Brunner Islanc). Tnese concentrations returned to background levels in the following quarter comoosite at all downstream locations. The dose imolications of these H-3 levels are discussed under " Assessment of Impact". Results of analyses of surface water for Sr-89 and Sr-90 are presented in Tnese analyses were made on untreated water from the Brunner Table B-3. Island water treatment facility (SE1), the Steelton municipal water works (15F1) and the Columbia water treatment plant (7G1). All but one Sr-89 con-centration was below tne MCL (1.0 pC1/1); Sr-90 concentrations were less tnan 1 1.0 pCi/l in all of the samples analyzed. Gama spectrometric analysis of surface water samples (Table B-4) showed that the naturally occurring nuclides K-40 and Ra-226 were present at concentrations above their respective MDLs in 3 and 7 samples respectively. The fission l products ZrNb-95 wer'e founc in 2 samples. These nuclides were oetected in an upstream sample in October and a downstream sample in November. The measured concentration (4.4 0.7 pCi/1) downstream was greater than 10 times the control station value (<0.4 pCi/l) and was reported to the USNRC in accordance with TMI-1 ETS. This racionuclide was probably not of TMINS origin but rather the result of fallout from the Chinese atmospheric nuclear detonation of September 25, 1976. As stated earlier, similar levels were detected in the 4 upstream sample during the previous month and at other reactor sites in :ne Mid-Atlantic region during this period. Fish Fish samples were collected at 2 locations each in July and October of this reporting period. Adult fisn were taken for samoles each weighing about 2 kg. These were seaarated into classes of bottom feeder versus predator-game scecies; fillets were analy:ed. Gama spectrometry (TGC) and Sr-89 and Sr-90 analyses (SRD SRB) were performed on subdivided fish samoles. The results of these analyses are given in Table B-5. Sr-89 was not cetected in any of the samoles. Sr-90 was cetected in 7 of the 3 samoles.with the hignest value of 108 pCi/kg detected in tne upstream samole (1531). The gama soe:trometric results show natural X 40 present in all fisn samples, as expected. Tne gama emitters ZrNb-95 and Cs-137 were detected in 1 and 2 samoles, respectively; none of these levels were recortacle. No other gama emitters were detected. Typical MCLs by tais metnod are listed in Table B-20. 1448 J88 10

i e .m i a .m =- .m. { 'n [ Aw - i, m= I Aw I 'I M ke I m i. g3 w =,=.- _ _a .a J5 + a / w, m s I s Aw ~, a 2nr = - 3 s,> , =

3 E G

/ 7! M E I = a I .I & 5 = .= i

5 - ;;;

w

5 -
  1. e a

./ .m ,s = .m, o% A g ~ """ % g m= A. 11BdV --_~__'% W on .m ./ = m i W..__ s = 'g ms n s, Der,- 55 Aw. t k 7 AW 11BdV

  • I.'

e.,!.%s w L. 2 3 o I t/l*4 1448 089

i Sediment i Three sediment samples were taken in July and again in October. All samples were analyzed for Sr-89 and Sr-90 and gama emitting nuclides, by RMC analytical procedures SRD, SRS and TGC, respectively. Strontium in sediment results are given in Table B-6. Sr-89 was detected in 3 samples while Sr-90 was detected in 6 of the six samples. Indicator and control samples showed similar levels of both nuclides. The results of the gama analyses are given in Table B-7. The naturally occurring radionuclides (K-40, Ra-226 and Th-232) were found in all 6 sediment samples. The gama emitters Zr-95, Nb-95, Ru-103, I-131, Ce-141, and Bala-140 were detected at station 981 in Octooer at conccntrations significantly hignee than those at the control station. A nonroutine report was sucmitted on this sampl e. The elevated levels of these nuclides were probacly not the result of TMINS operations. The dose imolications of these results are discussed under " Assessment of Impact". Other gama emitters detected at low levels were Be-7, Pa-54, Co-58, Sb-125, and Cs-137. Atmosoheric Environment The atmospheric environment around TMINS was examined by analy:ing air particulate filters, charcoal cartridges and precipitation samoles. Air particulate samples were collected at 9 locations witn low volume air samolers using Hollingsworth and Voss HV-70 gauze cacked filters. At 4 of these locations, air iodine samples were collected on Cesco "B" cnarcoal flow through cartridges connected in series following the air particulate filters. Air volumes sampled were measurec with temperature compensated cry gas meters and recorded. Both air particulate and iodine samples were collected weekly. Precipitation was collected by using a 12 inch diameter funnel draining into a 5 gallon polyethylene bottle. The accumulated samples were collected and composited for monthly analysis. The amount of precipitation whicn fell j during the sampling period was measured 7.2d recorded. Air Particulates All air particulate samples were analyzed weekly for gross beta activity by RMC procedure TBD and monthly ccmcosites of all indicator and of all control samples were examined for gamma emitting nuclides by RMC procedure TGC. -1 Results of the gross beta analyses are listed in Table B-8. Gross concentrations of beta emitters in air remained relatively constant through Septemcer. During the first week in October beta activity at both indicator and background locations increased dramatically. This increase was obviously the result of the Chinese Nuclear Weapons Test of September 26, 1976. The indicator ano j control monthly averages plotted in Figure 2 demonstrate these trends anc snow similar benavior at bota indicator and control locations. Mcntnly gross ceta activity in all samples averaged.0.022 pCi/m from January througn Septemoer, while tne Sectember througn Decemoer activity averaged 0.137 pCi/m. 1448 390 12 4 " NM _ %**M N *

  • 96

_1- -W e '032

  • n 5

au3s E!

  • n s-

-S A1nr ~ g -. Il I AW e, l I li m o s GJ l a 1s .y = m 05 =2 35 .g % s

    • JV I

G E f AY 4 2 - 3 3rr - e l ! E, m l 1$N j y M 5

  • 03 r

a-( "o ~ e s A ( i g=n .r j p 3a e, 'n 2* f =v uas 3 5 = f 'n Aw, p A DKr 5 T' gyp 1: e I g% f 7 cJ t .m ,) 5 'n E 'm 5 uss .5 'n I 2a g AY[ t ",an 1 3rr : d t s h, 1! m s VNN k 'GJ r.? >n .,y v f[@ i r'. .,, i i i i i e i

v. f'J g

g o o s (n:a ~

The gama spectrometric results on monthly composites of air particulate filters are presentea in Table B-9. Prominent nuclides found in samples were naturally occuring Be-7 and the probable fallout nuclides, Ce-144, Ce-141, Bala-140, Cs-137, Ru-103, Mn-54, Zr-95 and Nb-95. As expected, the concentrations of these nuclides increased at both indicator and control locations following the Chinese Nuclear Test. I-131 was detected in both indicator and control composites imediately following the test. Typical MDLs for gama spectrometric analysis of air particulate samples are listed in Table B-20. Air Iodine iseous iodine was collected on charcoal cartridges at 4 locations. The .aulting samples were analyzed weekly for I-131 by RMC procedure IXB. Results are listed in Table C-10. All but 4 results were less than the respective MDLs which were of the order of 0.01 pCi/m". The four positive values were observed imediately following the Chinese Nuclear Test at all four sampling locations. Precipitation Monthly precipitation samples were analy:ed 'for gross beta activity by RMC procedure TBA. Tne RMC analytical procedures HXH and TGC were utilized for the analysis of H-3 and gama emitting nucli' des, respectively, in quarterly composites of precipitation from each station. Concentrations of Sr-89 and Sr-90 (RMC precedures SRC, SRA) were cetermined in semi-annual com csites from each station. Tne results of gross beta activity measurements in pre-cipitation samples are presentea in Table B-11. As with other atmospheric media, gross beta activity increased dramatically following the Chinese Nuclear Test. Tne data for the period prior to the test averaged 5.1 pCi/l while averaging 213 pCi/l after the test. Tne wet deposition of beta activity averaged 0.5 nCi/m*, prior to tne test (Table B-12). No significant differences between indicator and control locations were observed. The results of analyses of quarterly composites of precipitation for H-3 and gama emitting nuclides are presented in Table B-13. Tritium concentrations averaged 170 pCi/1. Various gama emitting nuclides were detected in precipitation. These gama emitters were those discussed under air particulates and were only detected after the Chinese test. The observeo levels of these nuclides were similar at both indicator and control locations. Typical MDLs for gama spectrometric analyses of precipitation are listed in Table B-20. Semi-annual composites of precipitation samples from each station were analyzed for Sr-89 and Sr-90 and the results are presented in Table B-la. Of the 8 samples analyzed, 5 contained detectable levels of Sr-90 while Sr-89 was detected on 4 samoles. All but one of the detectable levels occurred after the Chinese test. All increases were observed at both indicator and control locations. 1448 092 14

Terrestrial Envi ronment The terrestrial environment around TMINS was examined by analyzing samples of milk from 5 locations on a monthly basis and green leafy vegetables on an j annual basis. Two goat milk samples were also collected. Two gallon milk samples were collected and shipped fresh to RMC. Each sample was analyzed for I-131 using RMC procedure IXD. Quarterly composites from each station were analyzed for Sr-89 (SRC) and Sr-90 (SRA). Green leafy vegetables (cabbage), fruits (apples & peaches), and alfalfa samples were taken in July at 6 stations. Each sample was analyzed for gamma emitters by RMC procedure TGC. l The results of I-131 analyses of milk are presented in Table 8-15. None of the 35 milk samples analyzed before October showed detectable levels of I-131. The October and November samples had detectable concentrations of I-131 in 5 and 4 samples, respectively, due to Chinese fallout. Nonroutine reports were submitted for three of these results on the basis of ETS reporting levels. t Station to station ecmcarisons of milk results are not necessarily valid since I many herd specific factors control this pathway. Based on observations at 6 other nuclear facilities near TMINS and on data from government programs, I these concentrations are the result of Chinese Weapons test fallout. Concentrations of Sr-89 and Sr-90 in quarterly camcosites of milk samoles are listed in Table B-16. Of the 20 samples analyzed, Sr-89 was detected in one wnile Sr-90 was ~ detected in 14. Results from indicator stations were similar to nose from tne l control station and all results were similar to preoperational levels. The results of garna spectrometric analysis of green leafy vegetable, fruit and alfalfa samples (Table B-17) showed detectacle levels of natural K-40 in all cases and of Be-7 in both alfalfa samples. No other garca emitters were detected. i [ Direct Radiation I The ambient radiation levels in the area of Three Mile Island Nuclear Station were determined with energy compensated calcium sulfate (Tm) thermoluminescent I dosime ters. A total of 78 quarterly TLD packets (4 TLDs each) were placed at i 21 locations around TMINS. The results of the TLD measurements are presented i in table B-19. All TLD results presented in this report have been normalized to a standard month (30.4 days) to eliminate the differences in exposure i periods. The resulting dose rate was similar to preoperational levels averaging, t 5.6 mrad / standard montn. Statistical analysis shows that tne fourth cuarter TLD results were significantly higher than the previous 3 quarters (t.05=2.08, := 4.75, df=59,17). This increase was tne result of the Chinese bomo test since no I statistical difference between control and indicator stations can be sr.own (t.05= 2.54,t=1.65,df=5,11). The projected annual dose comouted from results for this reporting period is 67 mrads, or 67 mrem assuming a quality factor of 1. An annual cose equivalent of 32 mrem was comouted ror the Harriscurg area and puolisned by tne E?A(14). The difference between tnis calculated value and ne measured RMC value is not considered significant because of the differences in tecnnioue and the statistical variability of eacn. The average monthly amoient raciation dose rates for indicator and control stations are plotted in Figure 3. Ne trends in amoient gamma radiation levels as a result of TMI-1 operations are apparent from tnis 1448 393 S"'P^- 15

e t' 1 I .or m

  • n

'm 8 '143$ 55 n as Av -w

  • ff e

I AW 1 7!&fY I t 4 Il ga 3

  • GJ c

me E5

==h.a:n ~ .g s's,

  • 1423 a3 l

ATC a i l 3 ~ $N ~ g 5 E ) AW /

  • !&iY b

s' E O / w5 d og3 2 Y f. 's 'WF 5 N j ? n = 1 a d, L m i ? 'Lf3$ ( A q y ( M b 5h j AW lI M s \\,, N 'm ,/ .c 1 =' = ac 'O KA 'a ,i = = s% [

  • 1d33 1

.a ~, 2: ,,8'- _s h($ Ef ATJ' ~ y'% kb 1lNY j 'CdW 'OJ F 8 'wr p.0 i a a i e i OS 5 aE M e M C1.WN13,%% 1 15 1448 J94 ~

.se****** ASSESSMENT OF IMPACT I The gaseous and liquid effluent streams from TMI-1 were continously samoled and/or monitored for the presence of radioactive materials by Metropolitan j Edison Company. The REMP was designed and conducted in a manner to permit t identification of the radionuclides actually released from the station. t Of the radioactive materials released from TMI-1 to the environs, only H-3 in surface water and various gamna emitters in sediment shcwed a potential j contribution from TMI-1. Those samples which resulted in non-routine reports are listed in Table a. e Thus, the only pathways for potential exoosure of individuals or of a segment of population to radioactive materials from station operation is from consumption 8 of river water or from shoreline deposits. Untreated river water is monitored as part of the TMINS REMP at 2 locations (Brunner Island, SEl, and Columbia, 7G1) in the downstream vicinity wnich use treated river water continuously for human consumption. At no time during the reporting period did H-3 levels at these sta'tions differ statistically from those at the upstream station. It can then be ;cncluded that these H-3 levels did not result in a significant dose to man. A variety of fission products were detected in one downstream sediment sample during October at low concentrations, but greater than the control location. I The conservative approacn would be to assume that all of these radionuclides would be of THINS origin. Based on the equations used in USNRC regulatory guide 1.109(17) a potential dose of 0.33 mrem was calculated. This calculation is for a hypothetical maximum teenager spending 34 hours (1/2 recormended 8 annual usage) on ground contaminated to the same degree as the sediment and i assuming a surface density of 240kg/m. These insignificant doses are the f m:xima which could be attributed to the radionuclides released to the Susquehanna f, River by TMI-1. I I i i I i i L i 4 1448 295 17

TABLE 4 1976 ENVIRONMEilTAL SAMPLE DATE WilICil RESULTED IN NON-ROUTINE REF00JNG TYPE OF SAMPLE TYPE STATION NO. SAMPLING DATES ANALYSIS RESULT UNITS REPORT SURFACE WATER 9A2 NOVEf0ER GAMtM Zrtib-95 4.410.7 pCi/l NRR SEDIMENT 9B1 OCTOBER GAlHA Zr-95 3.110.3 pC1/9(dry) HRR Nb-95 2.410.2 Ru-103 1.210.1 I-131 0.210.04 Ce-141 2.610.3 E Bala-140 0.810.1 MILK 783 OCTOBER I-131 4615 pCi/l NRR A b 1 C30 0W Ch

e _ CONCLUSIONS The preoperational Radiological Environmental Monitoring Program (REMP) conducted by RMC and Metropolitan Edison Company was continued as the operational program after TMI-1 initial criticality on June 5,1974 and as a preoperational program for TMI-2. The REMP (from January 1 througn Decemoer 31,197o) described in this repcrt was conducted according to the Environmental Technical Specifications for TMINS Unit #1 which permitted the objectives of the program to be met. g Additional sampling and analyses beyond those reouf red by the Tecnnical t l Specifications were performed as management audit samples. All results therefrom vere reviewed by RMC and Metropolitan Edison to assess all possible environmental pathways. Although other possible dose pathways to man were considered in the environs of the TMINS site, tritium in surface water and fission products in sediment I were the only radionuclides of potential TMINS origin detected above back-ground levels witn only sediment potentially contributing to case. The radiation dose to pecole from ambient garna radiation, as measured by thermoluminescent dosimeters, averageo 5.6 mrem /montn and shewed no evidence g of a TMINS contribution during this operational period of TMI-1. The radiation dose to people in the TMINS environs is ccmparea with :ne exposure from other { artificial and natural sources in the following table: i j Source of Excosure Annual Cose in mrem Medical 72(15) Ambient Gacma (TLD) 67 Radionuclices in body I (primarily X-40) 18(16) Normal Glocal fallout 4(16) Fission Produtts 0.33 in Sediment [ I-131 in Milk 60 _r (Chinese Fallout) I The possible contribution of TMINS is insignificant in comparison with just one { pathway associated with the Chinese fallout incident. Even though the potential j THI-1 contribution to population exoosure is very small (approximately 0.2'; of that from otner fources), TMINS has a continuing program to improve coerating t techniques and to maintain equipment directed toward reducing releases of radioactive materials to the environment. It can be concluded that operation f of TMI-I did not significantly alter the radiological enaracteristics of the TMINS environs. due to natural radioactivity and global fallout.The radionuclides and radiation leve f i 1 e i 1448 397 19

~ t. j REFERENCES i (1) Metropolitan Edison Company. "Three Mile Island Nuclear Station-4 Technical Specifications." Appendix B. DPR 50, 1972. l (2) Radiation Management Corporation. "Three Mile Island Nuclear Generating Station-Preoperational Radiological Environmental Monitoring Program". RMC-TR-75-17, 1975. (3) Radiation Management Corporation. "Three Mile Island Nuclear Station-Radiological Environmental Monitoring Program-First Operational Period." RMC-TR-75-02, 1975. (4) Radiation Management Corporation. "Three Mile Island Nuclear Station-1975 Semi-annual Report". RMC-To-75-13, 1975. (5) Radiation Management Corporation. " Radiological Environmental Manitoring Report for v.ne Three Mile Island Nuclear Station 1975 Semi-annual Report II, July 1 through Decemoer 31". RMC-TR-76-01, February 1976. (6) United tates Cepartment of the Interior-Geological Survey. " Water resources Data for Pennsylvania, Part-1." 1973. l (7) Radiation Maaagement Corporation. "Three Mile Island Nuclear Generating Station-Agricul tural Land Use Survey". RMC-TR-75-1, 1975. (8) Metropolitan Edison Company. " Environmental Re ort, Operating Lict.nse Stage-Three Mile Island Nuclear Station Unit 1 and Unit 2", 1971. (9) United States Atomic Energy Commission. " Final Environmental Statement-Three Mile Island Nuclear Generating Station Units 1 and 2". DOCKET N0s. 50-239 and 50-320, 1972. (10) Metropolitan Edison Company, Jersey Central Pcwer and Light Company, Pennsylvania Electric Company. " Final Safety Analysis Report, Three Mile Island Nuclear Station-Unit 2". Docket No. 50-320, 1974. (11) Metropolitan Edison Company, Jersey Central Power and Light Company, Pennsylvania Electric Ccmpany. " Environmental Recort Supplement II, Three Mile Island Nuclear Station." Docket No. 50-320, February 1975. (12) Radiation Management Corporation " Analytical and Quality Control Program." RMC-TM-75-3, 1975. (13) Steel & Torrie, Princicles and Procedures g Statistics. McGraw-Hill Book Company, Inc., New York, 1960. 1448 M8 20 - w

i I' REFERENCES (Cont.), J (14) Donald T. Oakley, " Natural Radiation Excesure in the United States," U.S. Environmental Protection Agency, ORP/SID 72-1, June 1972. (15) S.E. Thompson, C. A. Burton, D.J. Quinn and T. C. Ng, "Concen-tration Factors of Chemical Elements in Aquatic Organisms." UCRL-50564 (Rev.1), October 1972. (16) "The Effects on Populations of Exposure to Low Levels of Ionizing Radiation" (BEIR REPORT). National Academy of Sciences,1972. l (17) United States Nuclear Regulatory Commission. Regulatory Guide 1.109 " Calculation of Annual Cases to Man from Routine Releases of Reactor. Effluents for the Purpose of Evaluating Compliance with 10 CFR Part50, Appendix I", 1976. f L i t i t I t i t 1448 099 i 21

9 y VI I i t t n B 0 I APPENDIX A i l 6 l b I 1448 100 f 23 ii ee -

7 APPENDIX A Samoling Locations Samle Identification pyC identifies samoles by a three-part code. The first two letters are the power station identification code, in this case TM. The next one to three letters are for the media sampled. AI = Air Iodine FPL = Green Leafy Vegetables AP = Air Particulates ID = Imersion Dose (TLD) AQF = Fish M = Mil k AQP = Aquatic Plants RW = Precipitation AQS = Sediment SW = Surface Water i E = Soil V = Fodder Crops FPF = Fruit The last four symcols are a location code based on direction and distance k from the site. Cf the last four symbols, tne first two repre:ent eacn of the sixteen angular sectort of 22-1/2 degrees centered abou the reactor site. Sector one is divided evenly by the nortn axis anc the otner sectors are numbered in a clockwise direction; i.e., 2=NNE, 3=NE, 4=ENE, 5=E, etc. The next digit is a letter wnich represents the racial distance from tne j plant: S = On-site location E = 4-5 mil es off-si te A = 0-1 miles off-site F = 5-10 miles off-si te B = 1-2 miles off-site G = 10-20 miles off-si te L C = 2-3 miles off-site H = >20 miles off-site D = s-4 miles off-site { I The last number is the station numerical designation within each sector and zone; e.g. 1, 2,... I j The location portions of these codes (i.e.151, 3A1, etc.) are shown in the attached table along with more detailed information and a map coordinata e [ number used to designate the individual samples in the analytical result tables, Appendix 3. I i t I i i 1448 101 2s

l TABLE A-1 i RADIOLOGICAL ENVIRONMENTAL HONITORING PROGRAM SAMPLING LOCATIONS LOCATION MAP CODE NO. DESCRIPTION

  • 1S1 1

0.4 miles N of site IS2 2 0.4 miles N of site 2S2 3 0.7 miles NNE of site on light pole in middle of North Bridge 2S3 4 0.7 miles NNE of site beside guard house at North Gate 4S2 5 0.3 miles ENE of site on top of dike, East Fence SS3 6 0.2 miles E of site on top of dike, East Fence 851 7 0.5 miles SSE of site at South Weather Station 9S2 8 0.4 miles S of site at South Beach of Three Mile Island J 11S1 9 0.1 miles SW of site, west of fkchanical Draf t Towers on dike 1452 ~10 0.4 miles WNW of site at Shelly's Island picnic area 16S1 11 0.2 miles NftW of site at gate in fence on west side of Three Mile Island 1A2 12 0.7 miles N of site at north tip of Three Mile Island. 4A1 13 0.5 miles ENE of site on Laurel Rd., Met. Ed, pole #668-0L sal 14 0.4 miles E of site on north side of Observation Center Building 9A2 15 0.5 miles S of site below Discharge Pipe llAl 16 0.2 miles SW of site off Discharge Pipe 16Al 17 0.4 miles NNW of site on Kohr Island 461 18 1.1 miles ENE of site, west of Cringrich Road =. Sul 19 1.0 mile E of site on Peck Road p= 7B3 20 1.6 miles SE of on cast side of Conewago Creek CC) 961 21 1.5 miles S of site, above York llaven Dam .- O l

l I i TABLE A-1 (CONT.) RADIOLOGICAL ENVIRONMcNTAL MONITORING PROGRAM SAMPLING LOCATIONS LOCATION MAP CODE NO. DESCRIPTION

  • 982 22 1.4 miles S of site, north of York llaven Dam 1081 23 1.1 miles SSW of site on south beach of Shelly's Island 1281 24 1.6 miles WSW of site adjacent to Fishing Creek 1681 25 1.1 miles NfM of site below Fall Island ICI 26 2.6 miles 11 of site ar Middletown Substation 1C3 27 2.3 miles it of site at Swatara Creek 8Cl 28 2.3 miles SSE of site 14Cl 29 2.7 miles WNW of site near intersection of Routes 262 and 392 Of 8El 30 4.1 miles SSE of site at Brunner Island IFl 31 6 miles N of site at flunmelstown Substation on Fiddler's F.lbow Road SF1 32 9 miles E of site on East Ridge and Greentree Roads SF2 33 5.8 miles E of site at Masonic llome 7F1 34 9 miles SE of site at Drager Farm off Engle's Tollgate Road 15F1 35 8.7 miles IN of site at Steelton Municipal Water Wor ks 2G1 36 2 miles llNE of Ilershey on Rt. 39 llunmelstown 4G1 37 10 miles EllE of site at Lawn - Met. Ed. Pole #J1813 7G1 38 15 miles SE of site at Columbia Water Treatment Plant 9G1 39 13 miles S of site in Mit. Ed. York Load Dispatch Statinn 15G1 40 15 miles IM of site at West fairview Substation i

Sill 41 80 miles E of site on RMC roof in Philadelphia ~g Sil2 42 80 miles E of site on RMC roof in Philadelphia m 8 All distances are measured from a point that is midway between the Reactor u Buildings of Units One and Two

~ N \\ I / 16 1 2 3 i \\ \\ I 15 \\ \\ / s' \\ \\ N / \\ .\\. - 1, ' / H E NRY 15L AN / / I f I 3 'x N / /N / ~ N I \\ \\ KoHR / 4 GooSEHCRN 15L ANO \\\\p/ f gistAso ,J --; # s / / N \\ [ / [je / \\ a\\ / f s f I s / Nat g t , l o, Is [qp. I l... 7', / u-f m s ~ ]3 T

  • g 8I, I

e e p p,fh] y' ~i]'- I 'sa m tY ~, i \\ \\ N / ISLAND / ~ \\ / g N / l 8 / ~ \\ / \\, \\ \\ 12 / / l' % 7 gf f / / 3 \\ \\ '/ p' \\ /8E ECH N y / \\ / ISLAND \\ \\ f N / f N / N -6 l Q /' y 'g' - ' T$ \\ g h ' ,'/ ~ / Ii / h D \\ / N D / \\ / / \\ / \\ v / \\ / I \\ / / / \\ (r Y '/ s l \\ \\ / b',% ~ / l j , ',, h,,,, / 4 ,,,a. i.i...d m \\ \\ j' ,1 - f J I/ g ~ \\ s q ~ 7 k \\ j o 10 / 9 8 \\ 2.5": 1 milo g g3 34 I THREE MILE ISLA"3 NUCLEAR STAT!CN Location of Ocerational Radiolocical Envirormental Monitoring Statiens wi nin 1448 g0A< The Site Soundaries 23

L M MQs,/ N.....l.x '.i... / .. w g '\\ s ~ ,{,. / )f, I /\\ \\ ~, w~

    • .,,e,'

y, 9.%.... 7........ 8..,., ~ 3 ,.j..g 's / \\,*' f W ' vt 's,' N I / ~~ 3 i / s' \\ j% i,... .L - o \\ r .s,. 'u r,,* o s s s \\ h !. / '.,/ N,/ \\4 7g sf s- /~, a, /),sh = \\. / ', \\ g / '%,/ p '\\ i,4"~~ \\ g lQ l \\ o s s \\ l t s '/

=== =Ja* ,o ,p -/ J9 / g\\ ,4. h-,, \\ ,e g f i / \\ '., p c= "_'%, ,e i l- .l ' f.'!= M '.,u, ,4,'f. i 'T/ A _,/\\l'7 ' -4 (~,a. ,_s,'-(f W 7k ' a,'1.'!$ 1 l ,\\ 1 \\ t-? t -$' & ~ ~ \\. -I.9 l f y-l ,,) ; 3 l-C.L ,4 ~~-,3t

  • t

{ i i l 3 Fif. l l 1 i .g s f s s..e -1 \\ I/I I J f <'\\, l ] \\ ~ l s j q \\ ,V,ai 'x \\. s. \\ /\\7m x 2, u .e" / l l' '\\ >= / 's l 2 / -4........ .s s k \\ / k \\ \\, f,,

  • -{&

~ j \\ 'N, / '..,,l \\ \\ ,/ / IENIjIhT C/ ] '\\, \\ ,/ / '~~ ( g "s, "4 \\, N, 's, / \\ / 's, j l t - [\\ g 5, g' l \\ = ,\\ \\s s l \\ I N.., N ~ s's. l s \\ Map A-2 THREE MILE ISLAM YJCLEAR STAim Location of "ierat*onal Radiological Envir:nre' ital l Monitoring Stations within r 5 Miles of the site y L 29 1/1 18 10; g

i i \\ 15 16 U36 I i / 2 / 3 g 0, \\ l l \\ s \\ / / [ \\ / / N u5 p p \\ , e (~ ~ 4c. N j 4 NARRISBU G u j W, A ~ ~l / } s 37 -s sy f PA. TURNPtKE f A__ g N i f,{ Ud. IS L AN D 'I phi @41 I m' 2 D ~TOTL p T-l 1 13. 9 ( s I 5 4 l t"~~ ~6 /j J3', 's / -\\ \\ /4 1j

  • 4N

~ s ~~~ - \\ / [\\ / ) \\ f ( / s / \\ \\ Y .i \\' / 'f \\ LANCASTER [ 9{ \\ / / s / \\ \\ 6 12 / YORK s s I \\ \\/ .4 N N g k 0- / N g N / \\ \\ / / I \\ \\ () 8 \\ 7 / 10 / 9 11 1*z APPR.loMILES Map A-3 THREE MILE ISLAND NUCLEAR STATION Location of Operationai Radiological Environmental Monitoring Stations Greater Than 5 Miles from tne Site 30 1448 106

W e O APPEtlDIX B i t i I 31 1448 107 ~;

APPENDIX B Data Tables Appendix B is a presentation of the results of the TMINS Radiological Envrironmental Monitoring Program. TABLE NR TITLE PAGE AQUATIC ENVIRONMENT B-1 Sampling Periods for Surface Water Samoles,1976 -----. 35 B-2 Concentrations of Tritium in Surface Water,1976 ---... 37 B-3 Concentrations of Sr-89 and Sr-90 in Untreated Drinking Water, 1976 ------------------------------------------. ,8 B-4 Concentrations of Gama Emitters 'in Surface Water, 1976 -------------------------------------------------- 39 B-5 Concentrations of Sr-89 and Sr-90 and Gama Emitters in Fish, 1976 ----------------------------------------- 40 B-6 Concentrations of Sr-89 and Sr-90 in Sediment,1976 --- 41 B-7 Concentrations of Gama Emitters in Sediment,1976 ---- 42 ATMOSPHERIC ENVIRONMENT B-8 Concentrations of Beta Emitters in Air Particulates, 1976 -------------------------------------------------- 43 B-9 Concentrations of Gama Emitters in Air Particulates, 1976 -------------------------------------------------- 49 B-10 Concentrations of I-131 in Fil tered Air,1976 --------- 51 8-11 Concentrations of Beta Emitters in Precipitation, 1976 -------------------------------------------------- 53 3-12 Be ta Emi tte r Depo si tio n, 1976 ------------------------- 54 B-13 Concentrations of Tritium and Gama Emitters in Precipitation, 1976 ----------------------------------- 55 B-14 Concentrations of Sr-89 and Sr-90 in Precipitation, } 1976 -------------------------------------------------- 56 1448 \\D8 33

l APPENDIX B Date Tables (Cont.) i i TABLE NUMBER TITLE ,PAGE TERRESTRIAL ENVIRONMENT B-15 Concentrations of I-131 in Mil k, 1976 ----------------- 57 B-16 Concentrations of Sr-89 and Sr-90 in Milk,1976 ------- 59 B-17 Concentrations of Garmia Emitters in Green Leafy Vegetables, Frui ts and Al fa l fa, 19 76 ------------------------------ 60 B-18 Concentrations of Gamma Emitters in Beef and Game, 1976 -------------------------------------------------- 61 DIRECT RADIATION B-19 TL D Do s e Ra t e, 19 7 6 ----------------------------------- 62 MINIMUM DETECTABLE LEVELS B-20 Typical MDLs for Gama Spectrometry,1976 ------------- 63 COW CENSUS B-21 Distribution of Milk Cows Within Five Miles of TMINS, 1976 -------------------------------------------------- 64 I 1448 109 34

TABLE B-1 SAMPLING PERIODS FOR SURFACE WATER SAMPLES (JANUARY-JUNE),1976 STATION NO. JAN FEB MAR APR MAY JUN TM-SW-lC3* 1-07-76 2-05-76 3-04-76** 4-01-76 5-06-76 6-03-76 to to to to to to 1-29-76 2-26-76 3-25-76 4-29-7; 5-27-76 7-01-76 TM-SW-15F1 12-31-75 1-30-76 2-27-76 3-26-76 4-30-76 5-28-76 to to to to to to 1-29-76 2-26-76 3-25-76 4-29-76 5-27-76 7-01-76 TM-SW-9A2 1-07-76 2-05-76 3-04-76 4-01-76 5-06-76 6-03-76 to to to to to to 3 1-29-76 2-26-76 3-25-76 4-29-76 5-27-76 7-01-76 TM-SW-9B1 1-07-76 2-05-76 3-04-76 4'-01-76 5-06-76 6-03-76 to to to to to to 1-29-76 2-26-76 3-25-76 4-29-76 5-27-76 7-01-76 TM-SW-8E1* 12-31-75 1-29-76 2-28-76 3-31-/6 5-01-76 u-30-76 to to to to to to 1-29-76 2-28-76 3-31-76 5-01-16 5-30-76 6-30-76 TM-SW-7G1 1-07-76 1-29-76 2-26-76 3-25-76 4-29-76 5-27-76 to to to to to to m 1-29-76 2-26-76 3-25-76 4-29-76 5-27-76 7-01-76 Mana9ement audit samples CD Sample container empty upon receipt at RMC due to leak 1

/ 1 ? TABLEB-1(C0flT.) SAMPLING PERIODS FOR SURFACE WATER SAMPLES (JULY-DECEMBER),1976 STATI0ft N0. JUL AUG SEP OCT fl0V DEC TM-SW-lC3* 7-01-76 8-05-76 9-02-76 10-07-76 10-28-76 12-01-76 to to to to to to 7-29-76 8-26-76 9-30-76 10-27-76 11-30-76 12-24-76 TM-SW-1SF1 7-02-76 7-30-76 8-27-76 10-01-76 10-28-76 12-01-76 to to to to to to 7-29-76 8-26-76 9-30-76 10-27-76 11-30-76 12-29-76 TM-SW-9A2 7-01-76 8-05-76 9-02-76 10-07-76 11-04-76 12-08-76 to to to to to to g 7-29-76 8-26-76 9-30-76 10-27-76 11-30-76 12-29-76 TM-SW-9B1 7-01-76 8-05-76 9-02-76 10-07-76 11-04-76 12-08-76 to to to to fo to 7-29-76 8-26-76 9-30-76 10-2'7-76 11-20-76 12-29-76 TM-SW-8E1* 6-30-76 7-31-76 8-28-76 9-29-76 10-30-76 11-27-76 to to to to to to 7-31-76 8-28-76 9-29-76 10-27-76 11-27-76 12-29-76 TM-SU-7G1 7-01-76 7-29-76 8-26-76 9-30-76 10-27-76 11-30-76 to to to to to to 7-29-76 8-26-76 9-30-76 10-27-76 11-30-76 12-29-76 .p- .t> Managenent audit sanples CO a 9

=. e w ea s

I '\\ TABLF B-2 C0tiCEllTRATI0ftS OF TRITIUM u! SURFACE WATER,1976 Results in Units of pCf/1 12 sigma STATI0tl ti0. JAti-fMR APR-Jurt JUL-SEP OCT-DEC AVERAGE UPSTREAM LOCAT!0 tis TM-SW-1C3* 400175 226126 131161 303170 2651228 TM-SW-15F1 197164 122164 233161 106171 164il21 UPSTREAM AVERAGE 2982287 1791161 1821144 2041279 2151200 O 00WilSTREAM LOCATI0 tis TM-SW-9A2 461275 180165 203165 97168 2351314 1H-SW-981 608176 120164 886176 366171 4951656 TM-SW-8E1* 113173 131174 96151 <80** 105144 TM-SW-7G1 175173 122164 237165 143274 1691100 4 h DOUllSTREAM CD AVERAGE 3391469 138157 3551717 1721265 2511449 [ Management audit samples Results confirmed by reanalysis.

i l f TABLE B-3 I CONCENTRATIONS OF SR-89 AND SR-90 IN UNTREATED DRINKING WATER,1976 Results in Units of pCi/l -l STATION NO. START DATE STOP DATE SR-89 SR-90 TM-SW-15F1 12-31-75 3-25-76 <0.8 <0.6 3 3-26-76 7-01-76 <0.5 <0.5 7-02-76 9-30-76 <1.2 <0.8 10-01-76 .12-29-76 <0.6 0.7:0.2 TM-SW-8E1* 12-31-75 3-31-76 <1.0 0.4 1.4 3-31-76 6-30-76 <1.6 <1.0 6-30-76 9-29-76 <1.4 <0.9 9-29-76 12-29 76 <1.2 0.5_1.5 I TM-SW-7G1 1-07-76 3-2f -76 <1.0 0.5:0.4 3-25-76 7-01-16 <1.2 0.6:0.5 7-01-76 9-20-76 <1.2 0.7 0.5 9-30-76 12-29-76 0.4 0.3 <0.4 Management audit sample i i 1448 113 38

TABLE B-4 CONCENTRATICNS OF GAMMA EMITTERS IN SURFACE WATER,1976 Results in Units of PC1/12 2 Sigma NUCtICE' $TATION NQ. FCUND JAN FEB MAA APR MAY JUN % 5W-1C3** K-40 <6.0 1629 <6.0 <7.0 <7.0 <3.0 % $W-15F1 <EL <MCL <MCL <EL (MCL (MCL TS SW-9A2 K-40 <7.0 <7.0 <8.0 (8.0 <7.0 <7.0 T&SW-931 Ra-226 <0.9 <0.9 <0.9 <1.0 <0.9 <0.9 % $W-8E1** (MCL (MCL <EL <MOL (MCL (MCL ' NSW-7G1 Ra-225 <0.9 <0.9 (0.9 <0.9 <0.9 <0.9 i aVCLICE' STATICN NO. FOUND JUL AUG SEP CCT NOV CEC TM-5W-1C3** K-40 <7.0 <7.0 <7.0 <7.6 <7.0 (7.0 TNSW-1!F1 K-40 C.0 <7.0 <10 <7.0 12:10 <9.0 ZrNb-95 (C.5 <0.5 <0.7 1.520.7 <0.4 (0.7 Ra-226 <0.9 <0.9 <1.0 <0.9 1.821.. <1.0 % 5W-9A2 T-40 <7.0 (7.0 12:11 <7.0 <7.0 <5.0 ZrNb-95 <0.4 <0.5 <0.4 <0.5 4.4:0.7 <0.4 TM-SW-981 K-40 <7.0 <7.0 <7.0 14:11

7.0

<7.0 Ra-226 <0.9 1.7 1.4 <0.9 2.121.2 2.121.2 <0.9 %3W-EE1** <MCL <MCL (MCL <MCL <MCL (MCL W SW-7G1 Ra-?23 <0.9 1.721.2 1.321.2 <0.9 1.521.2 <0.9 All other gama emitters <MOL, Table B-20 Management audit samples )448 \\\\A i i ~- _

i TABLE B-5 CONCENTRATIONS OF SR-89 AND SR-90 AND GAMMA EMITTERS IN FISH,1976 Results in Units of pCl/kg(wet) i 2 sigma SAMPLING STATION NO. SAMPLE TYPE

  • MONTH Sr-89 Sr-90 K-40**

ZrNb-95** Cs-137** UPSTREAM SAMPLES TM-AQF-1681 Rock Bass July <27 108114 31001310 <6 (7 TM-AQF-16B1 Channel Catfish July <17 1317 26001260 <6 <7 TM-AQF-1681 Rock Bass Oct. <7.2 <4.5 26001260 <4 1316 5 TM-AQF-1601 Catfish Oct. <10 1814 27001270 <4 <5 DOWNSTREAM SAMPLES TM-AQF-9B2 Rock Bass July <25 86113 31001310 <5 <6 TM-AQF-9B2 Channel Catfish July <22 2319 26001260 <5 <6 TM-AQF-982 Rock Bass Oct. <8 7.713.4 28001280 <4 <5 - TM-AQF-902 Channel Catfish Oct. <l.7 2.010.8 32001320 7.015.7 6.816.1 4> 5> CO ~* Bottom feeders - catfish, brown bull head; p;edator/ game - small mouth bass, rock bass. ]*

  • All other ganina emitters <MDL, Table B-20.

9 1 TABLE B-6 CONCENTRATIONS OF SR-89 AND SR-90 IN SEDIMENT.1976 Results in Units of pCi/k9 (dry) i 2 signa STATION NO. SAMPLING DATE SR-89 SR-90 TM-AQS-1A2 7-15-76 <18 7819 10-21-76 1616 1415 TM-AQS-981 7-15-76 <21 37210 10-21-76 3416 2415 TM-AQS-IIA 2 7-15-76 (10 5015 10-21-76 4.313.7 2114 0 M S::= CO M

? si I i 9 t m< wm D . e to .-* O. O. O. N Cs m --e.-e enN em Ln N t e M N.e C.O.C O O c-+O.C.O O.C.O.C O t/s.-g + w ++. -i w -e ON OLn O O M.N.O v v v m v v vCl O O O C4 O O O N. M. < s v.evv eO CO. mm E-O O M< Lo e=e 43 O. .=4 N. eeN emNN e N. to e e .J - O. O. O. O. c#a*.J O. O J - O. O O N vi i.n oe .o -i o. -e -e C1 Om E v 0 C O O 2 0 2 O CC E C O *=* w m < e vmvvvvvvvvvvvv f4 N mQ E O H Cs Z w W M E = N OW +1 m NN vv Cn M c3 @ N. O.O.M. N. m O. O. 'M. O. N. e mN LO E >t 8 I O N.e -eO O, O O, O e-e o. O O, O. N. O. O, O 6 v1 - -e - -i - -e -e c ON

m..m N m -* v. N. O O N. m. NQ Q O CO. e m

%=. < t =4 O. O. M N c-g e VV .v ClC i o C C O-m N W Cs E-CO O E CD W w O LaJ E C3. J W C3 b< O .+ to K.:- N. O. 6 - M. CD W M mN M.-* m m m.

  • C M

8 i C N O. O O. O.. J m. O O. O J *-e O. O O w e= v1 Ln -t +e O -e -e O. -e -< O C O *=4 N..CC O O C C E C O. O N Z O O M @ N La. D < s -e v v v v v v,- O t N O v m. v v v.. e eO C3 e C E O O v,1 w 02 ~O M m .-e ed c H m:s H g c N La M N vm W Z < LC c=8 O. O. O. O. O. c-4 m C W mN .-*.-e e-m.. 2 U I I C N O.O.O O O.=eO.O.O O'-eO.O O v Z vi m +e +1 +< -e -e -e -e e -e t O ON N. Ln O O N. ~. C% C O O C't CO O O ~ N. j U < t m O. v v V N.C.v v M vv L . t. O O OO mm C E.-e O OO sJ +J I E e e= l N e E <c m M. C. ~ N. 1 .eN m . e==* N N N. CD e a O N O. O. O. O. -.J -

  • J C. O.

J M C. O. O v1 Ln - -i c .O -O -e L O-N to O O O O E O E O m E O O. m

  • C I
    • v v v v v v v v N. v v v e

eN m -o O s.* E O O H e O 6 W v O m e Ln N-e-@N v CD La Ln O O N --* m %" I Nm N O m W Cs m .-e *=* --. m a a -* v -J -gNN O I v e I e s i e t M I e I - e e D U l O L.O 3 I wi V U 9 ats 4 CQ M f"" y N = % g"I 4 Z a = y y y cc c F-4r )448 \\\\7 42 9bQ,

f TABLE B-8 j CONCENTRATIONS OF BETA EMITTERS IN AIR PARTICULATES,1976 -3 3 Results in Units of 10 pCi/m 1 2 sigma STATION NO. START STOP DATE DATE TM-AP-lFl** TH-AP-5F1 TM-AP-7F1 TM-AP-9G1 TM-AP-15G1 12-31-75 1-07-76 1615 914 2215 1314 1815 1-07-76 1-15-76 2716 2515 1915 1514 2816 1-15-76 1-22-76 3215 2616 1615 2415 3017 1-22-76 1-29-76 1415 2016 915 1515 1715 1-29-76 2-05-76 1616 1916 2616 2216 1915 2-05-76 2-12-76 2416 2217 1615 1615 1816 2-12-76 2-19-76 1916 1815 2216 <33 2515 u 2-19-76 2-26-76 1517 1716 2417 1816 2217 2-26-76 3-04-76 2116 1615 1515 2315 1815 3-04-76 3-11-76 1915 1314 2015 1514 2115 3-11-76 3-18-76 1716 1915 2016 2415 614 3-17-76 3-25-76 2216 1625 2116 1718 2016 3-25-76 4-01-76 2316 2215 2416 1314 4-01-76 4-08-76 1315 1014 1714 1815 4-08-76 4-15-76 '316 2315 2415 2816 1-15-76 4-22-76 17 4117 3516 4217 4-22-76 4-29-76 4 1114 1014 1314 4-29-76 5-06-76 2vid 1415 1215 1515 5-06-76 5-13-76 2516 2415 2315 2615 5-20-76 1014 1514 1214 2115 j((5-13-76 5-20-76 5-27-76 1114 1014 1114 914 5-27-76 6-03-76 1214 1314 1014 1314 cx3 6-03-76 6-10-76 2816 2616 2115 53i23 2616 -- 6-10-76 6-17-76 2116 2217 1315 27 6 2015 6-17-76 6-24-76 1715 1313 1615 1414 1614 c4) 6-24-76 7-01-76 2315 2215 2215 1915 1815 7-01-76 7-08-76 1415 1815 1214 1314 814 7-08-76 7-15-76 1845 2114 9 14 67125 2315

TABLE B-8 (CONT.) { CONCENTRATIONS OF BETA EMITTERS IN AIR PARTICULATES,1976 -3 3 Results in Units of 10 pCi/m 1 2 sigma STATION N0. START STOP DATE DATE TM-AP-lFl** TM-AP-5F1 TM-AP-7F1 TM-AP-9G1 TM-AP-15G1 7-15-76 7-22-76 2716 1614 2215 1818 2315 7-22-76 7-29-76 1215 1915 2015 <28 1415 7-25-76 8-05-76 1715 2215 1715 2416 1815 8-05-76 8-12-76 2215 2014 813 2415 2015 8-12-76 8-19-76 1715 20t5 2015 4817 1915 8-19-76 8-26-76 2216 2716 3116 2916 3116 u 8-26-76 9-02-76 1715 2215 1315 1515 2415 9-02-76 9-09-76 1815 1915 1615 2015 2215 9-09-76 9-16-76 2216 2816 2616 3216 3017 9-16-76 9-23-76 2115 2015 2015 2816 9-23-76 9-30-76 6118 412 2215 1814 9-30-76 10-07-76 689124 575119 465119 645122 10-07-76 10-14-76 3511 201115 748128 154110 10-14-76 10-21-76 274116 6817 2515 8818 10-21-/S 10-28-76 9619 2516 6018 4817 10-28-76 11-04-76 + 149t4 10718 131110 11-04-76 11-10-76 + 357118 7518 7428 11-10-76 11-17-76 + 2715 8218 130110 11-17-76 11-23-76 + 125112 119110 8418 11-23-76 11-30-76 + 108110 6717 130110 11-30-76 12-08-76 + 5317 6216 5117 k .p. 12-011-76 12-15-76 + <5 1814 55i7 Is 12-15-76 12-22-76 + 6818 2415 42 t6 CO 12-22-76 12-29-76 + 1615 1414 3416 M

i ~ TABLE 8-8 (CONT.) C0flCENTRAT10N OF DETA EMITTERS IN AIR PARTICULATES, 1976 -3 3 Results in Units of 10 pC1/m 12 signa STATION N0. START STOP DATE DATE TM-AP-152 TM-AP-2S3** TM-AP-8S1 TM-AP-5Al 12-31-75 1-07-76 1915 2417 2115 614 1-07-76 1-15-76 2315 1914 2315 1214 1-15-76 1-22-76 26t5 2817 2216 1815 1-22-76 1-29-76 1315 1516 1515 <4 1-29-76 2-05-76 1615 1916 2016 1815 2-05-76 2-12-76 20t5 2117 1415 1615 2-12-76 2-19-76 1515 2216 1615 1515 ui 2-19-76 2-26-76 2017 1918 1417 1416 2-26-76 3-04-76 2316 1216 2215 1615 3-04-76 3-11-76 1614 1214 1614 1314 3-11-76 3-18-76 815 714 1615 1915 3-17-76 3-25-76 1715 1016 1314 915 3-25-76 4-01-76 2315 2716 2115 3116 4-01-76 4-08-76 1514 1517 1214 2916 4-08-76 4-15-76 1314 816 1814 1614 4-15-76 4-22-76 3416 3417 2315 3416 4-22-76 4-29-76 1414 1315 1014 814 4-29-76 5-06-76 2115 1616 1715 914 i 5-06-76 5-13-76 2115 1816 1815 2516 5-13-76 5-20-76 1214 2216 1514 1214 5-20-76 5-27-76 1214 5318 514 1014 5-27-76 6-03-76 1214 1415 1014 1414 6-03-76 6-10-76 2315 2715 2115 2515 6-10-76 6-17-76 2415 2516 2216 1715 6-17-76 6-24-76 1413 1515 1114 6-24-76 7-01-76 1915 1516 1015 1414 m 7-01-76 7-08-76 19!5 714 1214 514 7-08-76 /-15-76 1414 2015 2015 2215 N CD

t ~ ^ TABLE B-8 (CONT.) CONCENTRATIONS OF BETA EMITTERS Ill AIR PARTICllLATES,1976 Results in Units of 10-3 pCf/m 12 signa 3 STATION N0. START STOP DATE DATE TM-AP-IS2 TH-AP-2S3** TM-AP-8S1 TM-AP-5A1 7-15-76 7-22-76 1714 2516 2215 2115 7-22-76 7-29-76 1715 1116 1515 514 7-29-76 8-05-76 1615 72113 1715 2116 8-05-76 8-12-76 713 2616 513 2115 8-12-76 8-19-76 1714 1615 1815 413 8-19-76 8-26-76 2716 20112 2416 2216 8-26-76 9-02-76 1815 25122 <3 1815 g 9-02-76 9-09-76 2115 1716 1915 1515 9-09-76 9-16-76 2216 1817 2516 2516 9-16-76 9-23-76 1915 2015 2315 9-23-76 9-30-76 1514 <13 1814 9-30-76 10-07-76 347117 655123 202113 10-07-76 10-14-76 349116 149111 339116 10-14-76 10-21-76 2815 5016 11519 10-21-76 10-27-76 156112 7519 3817 10-27-76 11-04-76 10518 128110 172111 11-04-76 11-10-76 140110 136111 8119 11-10-76 11-17-76 74 18 7418 6717 l p 11-17-76 11-23-76 108110 8419 117110 m 11-23-76 11-30-76 1614 110:9 8718 CO 11-30-76 12-08-76 6617 5627 2615 12-08-76 12-15-76 5617 5717 4616 ~ 12-15-76 12-22-76 4617 3 12-22-76 12-29-76 3516 1615 1415 5117 4116

I TABLE B-8 (CONT.) CONCENTRATIONS OF BETA EMITTERS IN AIR PARTICULATES,1976 Results in Units of 10-3 pCf/m 1 2 sigma 3 STATION NO. START STOP DATE DATE TM-AP-1281 TM-AP-lCl** AVERAGE 12-31-75 1-07-76 2316 1712 1-07-76 1-15-76 1915 20110 1-lF-76 1-22-76 3015 25110 1- _-76 1-29-76 1515 1419 l-29-76 2-05-76 2115 2016 2-05-76 2-12-76 1/15 1816 w 2-12-76 2-19-76 2316 21111 2-19-76 2-26-76 1717 1817 2-26-76 3-04-76 2416 1918 3-04-76 3-11-76 1815 1616 3-11-76 3-18-76 1916 15112 3-17-76 3-25-76 2116 1718 3-25-76 4-01-76 2215 23110 4-01-76 4-08-76 2015 16111 4-08-76 4-15-76 2315 20113 4-15-76 4-22-76 80 t9 40132 4-22-76 4-29-76 1114 1114 4-29-76 5-06-76 1515 1517 5-06-76 5-13-76 2716 2317 j 5-13-76 5-20-76 1214 1418 - 5-20-76 5-27-76 1615 20137 4"" 5-27-76 6-03-76 1214 1213 3 6-03-76 6-10-76 2615 cx) 28118 6-10-76 6-17-76 2316 2118 6-17-76 6-24-76 16t4 1514 rs] 6-24-76 7-01-76 2415 1919 rs; 7-01-76 7-08-76 1615 1219 7-08-76 7-15-76 2215 18112

TABLE B-8 (CONT.) CONCENTRATION OF BETA EHITTERS IN AIR PARTICULATES, 1976 -3 3 Results in Units of 10 pC1/m 12 signa STATION NO. START STOP DATE DATE TM-AP-1281 TM-AP-1Cl** AVERAGE 7-15-76 7-22-76 2315 2117 7-22-76 7-29-76 1915 16112 7-29-76 8-05-76 1815 24134 8-05-76 8-12-76 1914 17115 8-12-76 8-19-76 2515 20122 8-19-76 8-26-76 2916 2618 8-26 9-02-76 2116 18il3 9-02-76 9-09-76 2215 1915 ,m 9-09-76 9-16-76 2516 2518 9-16-76 9-23-76 2115 216155 2216 9-23-76 9-30-76 1814 1715 21133 9-30-76 10-07-76 572121 ~ 729134 518 340 10-07-76 10-14-76 263117 494132 2001432 10-14-76 10-21-76 135110 5618 981162 10-21-76 10-27-76 99110 5619 75384 10-27-76 11-04-76 225113 145184 11-04-76 11-10-76 157112 1441184 11-10-76 11-17-76 8118 172112 87183 11-17-76 11-23-76 120111 108135 11-23-76 11-30-76 5017 95110 83174 11-30-76 12-08-76 6317 5417 53124 42-12-08-76 (2-15-76 1214 44t3 37141 4** 12-15-76 12-22-76 4517 1515 42132 C33 12-22-76 12-29-76 2116 <5 19121 3 ()$ Sampling equipment inoperative. ) Station ICI replaced stations 2S3 and IF1 on 9-16-76. + No sample received. (

I TABLE B-9 CONCENTRATIONS Of GAMMA EMITTERS IN AIR PARTICULATES,1976 -3 3 Results in Units of 10 pCf/m 1 2 s1 ma 9 12-31-75 1-29-76 3-04-76 4-01-76 4-29-76 6-03-76 to to to to to to STATION NO. NUCLIDE* l-29-76 3-04-76 4-01-76 4-29-76 6-03-76 7-01-76 TM-AP-BACKGROUND Be-7 5716 6216 110111 130114 110111 130113 Mn-54 0.410.4 <0.2 <0.4 <0.5 <0.4 <0.3 Co-58 <0.3 <0.2 <0.5 <0.7 <0.5 <0.3 Zr-95 <0.4 <0.4 <0.9 <0.9 <0.7 <0.5 Ru-106 <2.0 <2.0 <5.0 <5.0 <4.0 <3.0 Cs-137 0.510.4 0.410.2 2.710.9 3.411.2

1. 2 10.6 0.910.5 Ce-144

<2.0 <l.0 <3.0 <6.0 <3.0 <2.0 TM-AP-INDICATOR Be-7 4214 4014 4615 9019 6316 100110 + Mn-54 <0.07 <0.05 0.1010.04 <0.09 0.0810.06 <0.08 Co-58 0.210.1 <0.06 <0.07 <0.1 <0.09 <0.05 Zr-95 <0.1 0.110.1 <0.08 <0.1 <0.08 <0.1 ](( Ru-106 <0.6 <0.6 <0.5 0.810.6 <0.6 <0.7 f)$ Cs-137 0.110.1 0.230.1 0.210.1 0.610.2 0.410.1 0.510.2 Ce-144 0.810.6 2.010.8 2.110.6 1.410.5 2.011.0 <0.8 rv _p=

TABLE B-9 (CONT.) CONCENTRATIONS OF GAMMA EMITTERS IN AIR PARTICULATES,1976 -3 3 Results in Units of 10 pCi/m i 2 si gma 7-01-76 7-29-76 9-02-76 9-30-76 10-27-76 11-30-76 to to to to to to STATION NO. NUCLIDE* 7-29-76 9-02-76 9-30-76 10-27-76 11-30-76 12-24-76 TM-AP-BACKGROUND Be-7 7818 8619 7017 8018 78141 6516 Mn-54 <0.2 <0.09 <0.09 <0.2 <0.3 <0.2 Co-58 <0.1 <0.07 <0.1 0.610.4 <0.4 <0.2 Nb-95 <0.1 <0.07 <0.1 2813 1612 3.210.4 Zr-95 <0.3 <0.2 < 0. 2 3514 1512 3.210.4 Ru-103 <0.1 <0.08 <0.09 1411 1912 1.410.5 Ru-106 <l.0 <0.8 <0.8 <2.0 <3.0 <2.0 i g; I-131 <0.1 <0.09 <0.1 2.010.4 <0.4 <0.2 Cs-137 1.010.3 0.610.2 0.310.2 <0.2 < 0. 4 <0.2 Bala-140 <0.3 <0.1 <0.2 1111 5.011.3 <0.4 Ce-144 <0.9 <0.9 <0.7 5.111.4 1315 <l.0 Ce-141 <0.2 <0.2 <0.2 3213 2613 3.710.6 TM-AP-INDICATOR Be-7 6216 7718 5816 4514 4915 4815 FM-54 <0.1 <0.1 <0.1 <0.1 <0.1 0.09 Co-58 <0.09 <0.1 <0.1 0.310.2 <0.1 0.310.2 Hb-95 <0.1 <0.09 <0.1 1411 9.110.9 2.510.3 Zr-95 <0.2 <0.1 < 0. 2 1612 8.610.9 2.710.5 Ru-103 <0.1 <0.09 <0.1 1011 9.511.0 3.810.4 I Ra-106 <0.8 <0.9 <0.9 <2.0 <l.0 <l.0 1-131 <0.1 <0.1 <0.1 1.610.4 <0.1 <0.1 23, Cs-137 0.820.2 0.510.2 0.410.2 (0.2 <0.2 <0.1 23. Bala-140 <0.2 <0.2 <0.2 6.210.9 2.410.2 <0.2 cyo Ce-144 <l.0 <0.7 <l.0 7.613.0 2.010.21 <1.0 Ce-141 <0.2 <0.1 <0.3 1912 1011 3.010.4 NW All other 9amna emitters <MDL, Table B-20 Background stations are IF1, SF1, 7F1, 7G1, 15G1 Indica tor s ta tions are 1S2, 2S3, 851, SA1,1281,101 +

I TABLE B-10 CONCENTRATIONS OF I-131 IN FILTERED AIR, 1976 -3 3 Results* in Units of 10 pCi/m STATION NO. START STOP DATE DATE TM-Al-IS2 TM-AI-8SI TM-AI-5AI TM-AI-15G1 12-31-75 1-07-76 <8 <10 <10 <12 1-07-76 1-15-76 <6 <7 <7 <7 1-15-76 1-22-76 <8 <8 <10 <ll 1-22-76 1-29-76 <8 <8 <8 <8 1-29-76 2-05-76 <5 <6 <6 <6 2-05-76 2-12-76 <6 <6 <6 <6 2-12-76 2-19-76 <7 <7 <7 <7 u. 2-19-76 2-26-76 <8 <8 <8 <8 2-26-76 3-04-76 <7 <7 <7 <7 3-04-76 3-11-76 <6 <6 <6 <6 3-11-76 3-18-76 <8 <6 <8 <8 3-18-76 3-25-76 <7 <6 <7 <9 3-25-76 4-01-76 <7 <7 <7 <7 4-01-76 4-08-76 <7 <7 <7 <9 4-08-76 4-15-76 <8 <8 <8 <8 4-15-76 4-22-76 (9 <9 <9 <10 4-22-76 4-29-76 <10 <10 <12 <10 4-29-76 5-06-76 <10 <10 <ll <10 5-06-76 5-13-76 <7 <7 (7 <9 5-13-76 5-20-76 <9 <10 <9 <10 5-20-76 5-27-76 <10 <10 <10 <10 A 5-27-76 6-03-76 <8 <8 <8 <10 A 6-03-76 6-10-76 <7 <9 <8 (10 W 6-10-76 6-17-76 <7 <7 <7 <7 6-17-76 6-24-76 <4 <7 <9 6-24-76 7-01-76 <10 <l5 <10 <12 ~~ h 7-01-76 7-08-76 <11 <9 <10 (11

,j TABLEB-10(CONT.) CONCENTRATIONS OF I-131 IN FILTERED AIR,1976 3 Results* in Units of 10-3 pC1/m STATION NO. START STOP DATE DATE TM-AI-IS2 TM-Al-8SI TM-Al-SA1 TM-AI-15G1 7-08-76 7-15-76 <9 <9 <9 <7 7-15-76 7-22-76 <8 <8 <8 <9 7-22-76 7-29-76 <8 <9 <8 <9 7-29-76 8-05-76 <8 <8 <9 <9 8-05-76 8-12-76 <8 <8 <9 <9 8-12 '/6 8-19-76 <8 <9 <8 <8 8-19-76 8-26-76 <16 <19 <16 <16 8-26-76 9-02-76 <9 <9 <10 <10 g 9-02-76 9-09-76 <u <9 <8 <8 9-09-76 9-16-76 <17 <14 <l7 <17 9-16-76 9-23-76 <10 <10 (10 <10 9-23-76 9-30-76 <10 <45 <10 <8 9-30-76 10-07-76 99110 108111 6617 7618 10-07-76 10-14-76 <6 <6 <6 <6 10-14-76 10-21-76 <9 <9 <9 <7 10-21-76 10-27-76 <8 <7 <8 <7 10-27-76 11-04-76 <5 <6 <5 <5 11-04-76 11-10-76 <6 <7 <7 (7 11-10-76 11-17-76 <8 <8 <7 <9 11-17-76 11-23-76 <6 (6 + <6 11-23-76 11-30-76 <6 <7 <6 <6 ~ 11-30-76 12-08-76 <5 <5 <5 (6

  1. 12-08-76 12-15-76

<8 <8 (7 <8 9 2-15-76 12-22-76 <22 <18 <20 <20 9 2-22-76 12-29-76 <10 <.10 <10 <10 a Results corrected for decay. + Sample lost. Sample equipment inoperative.

e 1 TABLE B-11 o CONCENTRATIONS OF BETA EMITTERS IN PRECIPITATION, 1976 Results in Units of pCi/112 sigma STATION N0. START STOP DATE DATE TM-RW-8S1 TM-RW-SAI TM-RW-7F1 TH-RW-15G1 AVERAGE 12-31-75 1-29-76 8.013.0 4.812.8 9.113.1 4.012.8 6.514.9 l-29-76 2-26-76 1113 3.712.8 1213 7.913.2 8.617.5 2-26-76 3-25-76 5.812.3 1313 1613 6.512.4 10110 3-25-76 4-29-76 <l.9 4.012.2 3.512.1 3.312.1 3.211.8 t'J 4-29-76 5-27-76 3.512.4 5.712.6 6.612.6 <3.0 4.713.4 5-27-76 7-01-76 5.812.7 <3.0 3.412.5 3.812.5

4. 012.5 7-01-76 7-29-76 1213 9.612.9 5'.212.5 7.912.8 8.715.7 7-29-76 8-26-76 5.612.2 5.312.1

<3.0 6.512.2 5.113.0 8-26-76 9-30-76 <3.0 <3.0 6.213.2 <3,0 913.2 9-30-76 10-27-76 15318 15818 13918 15618 152217 10-27-76 11-30-76 365113(8C1) 782119 459115 358113 4911399 _ 11-30-76 12-29-76 1613 1513 4.912.4 4.912.4+ 10112 4 cc AVERAGE 491216 841448 561265 471214 591293 N CD d t Sampling period 12-01-76 through 12-29-76. d

- - - - ~ - - - - - - ,I i TABLE B-12 BETA EMITTER DEPOSITION, 1976 2 Results its Units of nC1/m 1 2 sigma STATION NO. I START STOP DATE DATE TM-RW-851 TM-RW-5A1 TM-RW-7F1 TM-RW-15G1 AVERAGE 12-31-75 1-29-76 1.010.4 0.610.3 1.110.4 0.410.3 0.810.7 1-29-76 2-26-76 0.510.1 0.210.1 0.410.1 0.310.1 0.410.3 2-26-76 3-25-76 0.210.1 0.410.1 0.410.1 0.210.1 0.310.2 3-25-76 4-29-76 <0.1 0.310.1 0.210.1 0.310.2 0.210.2 s. 4-29-76 5-27-76 0.210.2 0.410.2 0.410.2 <0.3 0.310.2 5-27-76 7-01-76 0.810.4 <0.4 0.St0.3 1.511.0 0.811.0 7-01-76 7-29-76* 1.210.3 0.910.3 0.510.3 1.210.4 1.010.7 n A AVERAGE 0.610.9 0.510.5 0.510.6 0.611.0 0.510.7 co y-Deposition Calculations Discontinued in August. so l

I 1 s TABLE B-13 CONCENTRATIONS OF TRITitM AND GAffiA EHITTERS IN PRECIPITATION,1976 Results in Units of pCl/l

  • 2 sirpa START STOP STATION NO.

DATE DATE H-3 Be-7* Co-58 Zr-95 hb-95 Pu-103 Co 141 Ce-144 Ra-226* IH-RW-tiSI 12-31-75 3-25-76 120i60 (MDL <0.5 <0.4 <0.4 <MDL <MDL <3.0 (0.8 3-25-76 7 M 160165 (HDL <0.5 (0.4 <0.4 (HDL <MDL <3,0 <0.9 7-01-76 9-30-76 120:56 16s8 <0.5 <0.5 <0.5 (HDL - <MDL <3.0 3.2s1.3 9-30-76 12-29-76 97s68 4.414.0 <0.8 4.4st.3 4.020.7 3.220.7 2.610.9 <2.0 <0.6 TM-RW-5Al 12-31-75 3-25-76 130163 (MDL <0.5 (0.4 <0.4 <HDL (MDL (3.0 <0.9 '3-25-76 7-01-76 (80 (HDL <0.5 <0.4 <0.4 (MDL <MDL <3.0 <0.9 7-01-76 9-30-76 86t54 1988 (0.5 <0.5 (0.5 (HDL (HDL <3.0 <l.0 9-30-76 12-29-76 270:27 5.423.6 <0.3 1.510.7 1.4:0.5 3.110.5 1.310.6 <l.0 (0.7 TibRW-7F1 12-31-75 3-25-76 110163 1416 <0.5 <0.4 <0.4 (HDL < HDL (3.0 (0.9 3-25-76 7-01-76 360166 (HDL <0.5 (0.5 <0.5 (HDL <HDL <3.0 (0.9 7-01-76 9-30-76 156:54 (HDL <0.5 <0.5 <0.5 (HDL (HDL <3.0 3.111.3 9-30-76 12-29-76 300170 37211 3.0 0.9 6316 '100t10 1222 1522 20t1 <2.0 U. TH-RW-15G1 12-31-75 3-25-76 100163 (MDL <0.5 <0.4 <0.4 (MDL (MDL <3.0 (0.4 3-25-76 7-01-76 190165 <MDL <0,5 <0.4 <0.4 (HDL (MDL (3.0 <0.9 7-01-76 9-30-76 108tS4 1429 (0.5 <0.5 <0.5 <HDL (MDL (3.0 1.911.3 9-30-76 12-29-76 3J1170 24:12 <l.0 44s4 65i6 1222 1223 52113 <2.0 All other 9 anna emitters (HDL. Table B-20. M 4* CO l CD

~ TABLE B-14 l CONCENTRATIONS OF SR-89 AND SR-90 IN PRECIPITATION,1976 Results in Units of pCi/1 l START START STATION NO. STOP STOP SR-89 SR-90 TM-RW-5A1 12-31-75 7-01-76 <0.6 <0.5 7-01-76 12-29-76 2.520.6 1.00.4 TM-RW-851 12-31-75 7-01-76 <0.6 0.5:0.3 7-01-76 12-24-76 2.8:0.6 1.1 0.4 TM-RW-7F1 12-31-75 7-01-76 <0.7 <0.5 7-01-76 12-29-76 2.6:0.6 0.8 0.4 TM-RW-15G1 12-31-75 7-01-76 <0.6 <0.4 7-01-76 12-29-76 7.7 0.8 1.00.6 1448 131 56

TABLE B-15 CONCENTRATIONS OF I-131 IN HILK,1976 Results* in Units of pCi/1 STATION N0. JAN** FEB** MAR APR* MAY JUN <0.06 <0.05 <0.04 <0.05 TFbM-481 TM-M-SBl <0.04 <0.06 <0.05 <0.05 <0.04 <0.04 <0.04 <0.04 TM-M-783 <0.04 <0.06 <0.05 <0.05 TM-M-14Cl ++ 0 TM-M-2G1 < 0. Ci <0.05 <0.04 <0.08 -h i a 4 CO N

............. -. ~.... - - - - - - - - ~ TABLEB-15(CONT.) CONCENTRATIONS OF I-131 IN MILK, 1976 Results* in Units of pCi/l STATI0ft fl0. JUL AUG SEP OCT NOV DEC** TM-M-481 <0.05 <0.05 <0.06 2.210.2 <0.06 TM-H-5B1 <0.05 <0.04 <0.05 0.410.1 2.410.2 TM-M-783 <0.05 <0.05 <0.05 4615 4.110.4 IM-M-14C1 <0.04 <0.05 <0.06 1.910.2 0.0810.05 IM-M-2G1 <0.05 <0.04 <0.05 3.210.3 0.0910.05 Resuits corrected for decay to sampling date. fio sample in January, February, December; non-grazing season, Samples collected on 5-01-76. t 2G1 replace IF2 in April. tt I M M CO l V

TABLE B-16 CONCENTRATIONS OF SR-89 AND SR-90 IN MILX,1976 f Results in Units of pCi/1 : 2 sigma START STOP* l STATION NO. DATE DATE SR-89 SR-90 TM-M-481 3-31-76 3-31-76 <1.4 2.00.6 i 5-01-76 6-30-76 <4.8 5.6 2.2 7-31-76 9-29-76 <1.3 4.7 0.6 i 10-30-76 11-27-76 <0.6 <0.4 l I TM-M-5B1 3-31-76 3-31-76 <0.8 0.9:0,4 5-01-76 6-30-76 <1.2 1.8:0.6 <1.3 1.0 0.6 7-31-76 9-29-76 10-30-76 11-27-76 <0.3 <0.3 i TM-M-783 3-31-76 3-31-76 <1.3 0.7:0.6 e 5-01-76 6-30-76 <2.2 3.2:1.0 7-31-76 9-29-76 <1.0

0. 5:0.4 10-30-76 11-27-76 2.2_1.9

<1.0 i TM-M-14C1 3-31-76 3-31-76 <1.3 1.6 0.6 5-01-76 6-30-76 <2.7 3.3 0.9 7-31-76 9-29-76 <2.4 1.8 1.1 10-30-76 11-27-76 <1.3 <0.9 TM-M-2G1 3-31-76 3-31-76 <1.1 1.8:0.6 5-01-76 6-30-76 <4.7 4.9 2.2 7-31-76 9-29-76 <1.2 <0.8 10-30-76 11-27-76 <2.0 <1.4 No sample collected in January, February, December; non-grazing season. 2G1 replaced IF2 in April, i 1448 134 s, '.~ ~

TABLE B-17 i l CONCENTRATIONS OF GAMMA EMITTERS IN GREEN LEAFY VEGETABLES, i FRUITS AND ALFALFA,1976 Results in Units of pCi/kg (wet) : 2 sigma 1 -I SAMPLING SAMPLE j STATION N0, DATE TYPE X-40* Be-7* -l TM-FPL-5B1 7-31-76 Cabbage 2300:230 <MOL TM-FPL-7B3 7-31-76 Cabbage 3000 300 <MDL TM-FPL-14C1 7-31-76 Cabbage 2000:200 <MDL TM-FPL-2G1 7-31-76 Cabbage, 2300:230 <MDL i TM-FP F-5F2 7-31-76 Apples 1000 100 <MDL TM-FPF-5F2 7-31-76 Peaches 2300 230 <MDL l 1 TM-FPF-12G2 7-31-76 Apples 1500:150 <MDL 8 TM-FPF-12G2 7-31-76 Peaches 2500:250 <MDL TM-V-581 7-31-76 Al.'a l fa 42000:4200* 850:390 1 TM-V-2G1 7-31-76 Alfalfa 26000:2600+ 780:410+ All other gama emitters <MDL, Table B-20 + pCi/kg (dry) I

448 135 60

j TABLE B-18 CONCENTRATION OF GAMMA EMITTERS IN BEEF AND GAME,1976 Results in Units of pCi/g (wet) : 2 sigma SAMPLING SAMPLE STATION NO. DATE TYPE X-40 Cs-137

  • TM-FPB-201 11-05-76 Beef 3.3:0.3

<0.005 TM-FPB-5F3 11-05-76 Beef 3.5 0.4 <0.005 TM-GAD-7F2 12-14-76 Deer 3.1 0.3 <0.005 TM-GAD-801 12-02-76 Deer 3.1:0.3 0.015 0.007 All other gama emitters <MDL, Table B-20. i 1448'l36 ,1

f l 1 I l TABLE B-19 8 TLD DOSE RATE, 1976 Results in Units of mrem / standard month i, 12-29-75 3-31-76 6-30-76 9-29-76 1 to to to to l STATION N0. 3-31-76 6-30-76 9-29-76 12-29-76 AVERAGE -l { CONTROL LOCATIONS TM-ID-1F1 7.09 0.14 5.84:0.26 5.56:0.55 5.38:0.36 5.97 1.54 TM-ID-7F1 7.62:0.60 7.05:0.45 7.03:0.14 8.49:0.25 7.55:1.37 TM-ID-4G1 5.95:0.25 5.86:0.26 5.54:0.40 7.13_-0.28 6.12:1.39 i TM-ID-9G1 6.43:0,28 5.81 0.27 5.42 0.23 6.53:0.48 6.05:1.05 l TM-ID-15G1 6.02:0.47 5.38:0.27 5.30:0.56 7.16:0.33 5.96:1.72 j TM-I D-5H1 5.75:0.24 4.80:0.30 5.00:0.22 6.27:0.20 5.46:1.36 INDICATOR LOCATIONS i TM-ID-152 5.48 4.32 4.91:0.40 4.85:0.08 6.08:0.22 5.33:1.15 i TM-IO-252 4.72:0.19 4.58#J.13 4.53_-0.23 5.46:0.53 4.82:0.86 TM-ID-452 5.52 0.37 5.59:0.60 5.59:0.87 6.30:0.21 5.75:0.74 TM-ID-553 5.18:0.29 4.57:0.41 4.86.-0.50 5.62:0.50 5.06-0.90 i TM-ID-851 5.69:0.64 5.28:C.36 5.13-0.37 6.06:0.63 5.54:0.84 1 TM-ID-952 5.69:0.14. 5.23:0.16 5.70:0.54 6.34:0.48 5.74:0.91 i TM-ID-1151 6.30 4.20 5.66:0.36 5.42:0.25 6.98:0.63 6.09:1.40 i TM-I D-14S2 4.74:0.46** 3.91:0.21 ++ 4.32:1.17 i TM-ID-16S1 6.32:0.13 5.63:0.66 5.36:0.64 6.66:0.46 5.99:1.20 i TM-I D-4 A1 5.59 0.13 4.68:0.25 4.93 0.42 6.03:0.19 5.31:1.23 j TM-ID-5A1 5.42:0.39 4.97:0.30 5.12 0.35 6.17_-0.19 5.42:1.07 TM-ID-16Al + 4.90:0.54** 4.55:0.35 ++ 4.72 0.49 Th-ID-1081 + 5.51 0.23"* 5.70:0.09 ++ 5.60:0.27 TM-ID-1281 4.81:0.14 3.99:0,37 4.03:0.21 5.47 0.41 4.58:1.41 TM-ID-1CI 5.05:0.16 4.50:0.18 4.15:0.21 5.90 0.59 4.90 :1.52 i AVERAGE 5.81:1.49 5.21:1.34 5.13:1.39 6.34:1.53 5.59:1.71 TLD's stolen. Quarterly saccling period 4-08-76 to 6-30-76. Results not calculated - no in-transit doses. + TLDs not collected due to icy river conditions. ++ g48 \\M 62

N TABLE B-20 TYPICAL HDLs* FOR GAmA SPECTROMETRY,1976 FOOD PRODUCTS SURFACE AIR (Green Leafy Vegetation, WATER FISH SEDIMENT PARTICULATES PREF!PITATION Fruits Beef) NUCLIDES (pCi/1) (pCi/kg) (pCi/g) (10-3pCl/m ) (pCi/1) (pCi/kg) 3 Ha-22 0.2 3 0.01 0.07 0.2 1 K-40 7 7 7 Cr-51 3 30 0.1 0.6 3 20 iti-54 0.5 6 0.01 0.2 0.5 3 Co-58 0.5 5 0.01 0.1 0.5 3 fe-59 1 10 0.03 0.1 1 6 Co-60 0.6 7 0.01 0 0.6 4 Zn-65 1 20 0.03 0..> 1 7 Zrut)-95 0.5 5 0.02 0.6 0.4 3 Mo-99 4 40 0.08 1 4 20 RuRii-106 2 20 0.1 1 2 10 Ra-Il0:n 0.4 5 0.04 0.9 0.4 2 Te-129m 7 20 0.2 1 7 40 1-131 0.4 4 0.01 0.1 0.4 2 Te-132 0.4 4 0.02 0.07 0.4 2 1-133 0.5 6 0.01 0.1 0.5 3 Cs-134 0.5 5 0.02 0.4 0.5 2 Cs-136 0.7 9 0.02 0.06 0.7 4 Cs-137 0.5 7 0.5 3 - Bala-140 0.6 7 0.03 0.3 0.6 3 2::- Ce-144 3 30 0.1 1 3 10 p= Ra-226 0.9 10 0.2 0.9 5 N 11i-232 2 20 0.4 2 10 At time of analysis.

TABLE B-21 y DISTRIBUTION OF_ MILK C0WS WITillN FIVE MILES OF THINS,1976 FAR1 FAMI NUF0ER FARM FARM NUMBER DIRECTION DISTANCE OF C0WS DIRECTION DISTANCE OF C0WS N 3.1 80 ESE 3.8 45 N 4.9 1 ESE 4.3 24 NE 2.3 20 ESE 4.5 32 NE 4.4 50 SE 1.4 42 NE 4.1 90 SE 4.0 1 ENE 1.0 39 SE 4.1 84 21 ENE 2.5 2 SE 4.7 50 ENE 4.2 38 SE 4.8 19 ENE 4.4 90 SSW 4.9 26 ENE 4.5 44 SW 4.7 1 ENE 4.8 57 WSW 4.0 2 E 1.0 69 WNW 2.7 25 E 3.5 26 WNW 2.9 4 ESE 2.3 25 WNW 3.1 4 45-ESE 3.1 1 WNW 3.6 28 D-C33 ESE 3.2 28 ~]} ESE 3.6 35 ( Total Number of Farms 32 Total Number of Milk Cows 1082 3 1 L}}