Notice of Violation from Insp on 770823-25
ML19256D256
Person / Time
Site: Crane 
Issue date: 09/16/1977
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML19256D243 List:
References
50-289-77-24, NUDOCS 7910170768
Download: ML19256D256 (2)


Text

_--_

i SEP 191977 APPENDIX A s

i

~

NOTICE OF VIOLATION t

l Based on the results of the NRC inspection conducted on August 23-25, 1977, it appears that certain of your activities were not conducted in full compliance with conditions of your NRC Facility License No. DPR-50 as indicated below. These items are infractions.

A.

10 CFR 50.54 states in part, that "Whether stated therein or not, j

the following shall be deemed conditions in every license issued:

...(c) Primary reactor containments for water cooled power reactors shall be subject to the requirements set forth in Appendix J."

Appendix J to 10 CFR 50, paragraph III.A.3(c) states: " Test leakage rates shall be calculated using absolute values corrected for instrument error.

Contrary to the above temperatures, pressures and vapor pressures used to calculate leakage rates for the April,1977, Type A test were not corrected for instrument error, f

B.

Appendix B to 10 CFR 50, Criterion XIV states in part, that "...

measures shall also be established for indicating the operating status of structures, systems and components of the nuclear power L,

plant...to prevent inadvertent operation."

The Three Mile Island Operation Quality Assurance Plan, Revision 6, Section 19, states, in part, that "The Station Superintendent is responsible for the station procedures relating to the operational status of the entire station."

Contrary to the above, measures which were established did not prevent inadvertent operatior, in that PP-V8 and PP-V64 designated as locked open on the locked valve list were found unlocked and shut on August 25, 1977, thus isolating manifolds A and H of the Penetration Pressurization System.

C.

Technical Specification 6.8.1 states in part, that " Written procedures shall be established, implemented and maintained..."

\\b0 7910170 7ff

i 1

1

({')

Appendix A 2

ggg3 y g g Administrative Procedure 1011, Revision 12, dated June 6,1977, paragraph 3.3.1 states, that "The locked valve list shall include i

the alpha numeric designation of the valve and its locked position and will be maintained in the Locked Valve Book."

i The Locked Valve List included the following:

I EG-V 1006 Locking device or collar installed EG-V 1007 Locking device or collar installed LR-V 1 Locked closed LR-V 6 Locked closed LR-V 49 Locked closed Contrary to the above, on August 25, 1977, the EG valves had no locking device or collar installed and the LR valves were not locked.