PNO-79-229:on 790710,cracks in a & B Steam Generator Feedwater nozzle-to-pipe Welds Were Reported.All Welds Will Be Examined & Repaired
ML19256C924
Person / Time
Site: Ginna 
Issue date: 07/11/1979
From: Bryan S, Klinger G, Nolan F
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
References
PNO-79-229, NUDOCS 7910150753
Download: ML19256C924 (2)


Text

.

s PRELIMINARY NOTIFICATION July 11, 1979 Oc PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-79-229 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance.

The information presented is as initially received without verification or evaluation and is basically all that is known by IE staff on this date.

Facility: Rochester Gas and Electric Company R. E. Ginna Nuclear Power Plant, Unit No. 1 Ontario, New York Docket No. 50-244

Subject:

CRACKS IN STEAM GENERATOR FEED WATER PIPING Ultrasonic and radiographic examination of both ("A" ana "B") steam generator feedwater nozzle-to-pipe welds have revealed cracking in the base material of the 90 degree elbow which attaches to the feedwater nozzle.

The crack indications are estimated to be 1/32 - 1/16 inch in depth origir.ating from the inside surface of the elbow.

The extent of crack indications on the "A" steam generator elbow are approximately 300 degrees around the inside circumference while the "B" steam generator elbow is exhibiting crack indications around the entire (360 degrees) inside circumference.

The licensee is in the process of continuing to examine the remainder of the feedwater piping welds inside the reactor containment.

Examinations and repair work are expected to keep the plant out-of-service for at least three weeks.

The licensee shutdown the plant on July 6, 1979, specifically to perform the examinations of feedwater piping as required by NRC Inspection and Enforcement Bulletin No. 79-13, entitled, " Cracks in Feedwater System Piping."

This PN is issued for information only.

The NRC Region I Office will follow-up on additional developments and the repair work during the course of routine inspections at the facility.

Media interest is possible because of public attention to nuclear power plant issues.

The State of New York has been informed.

A press release will be issued by the licensee.

NRC does not plan to make a press release.

NRC, Region I, (Philadelphia) received notification of this occurrence by telephone from the Acting Plant Superintendent at 4:35 p.m. on July 10, 1979.

Contact:

G. Klingler IE, x28019 F. Nolan IE, x28019 S. Bryan IE, x28019 CONTINUED 1447 319

  1. 910150 3

A PN0-79-229 Continued July 11, 1979 Distribution:

Transmitted H St Chairman Hendrie Commissioner Bradford S. J. Chilk, SECY Commissioner Kennedy Commissioner Ahearne C. C. Kammerer, CA Commissioner Gilinsky ACRS (For Distribution)

Transmitted:

MNBB P. Bldg $1 ".cc)

V. Stello, IE L. V. Gossick, EDO H. R. Denton, NRR Region H. L. Ornstein, EDO R. C. DeYoung, NRR J.

e, Fouchard, PA R. J. Mattson, NRR N. M. Haller, MPA D. Vassallo, NRR (MAIL)

R. G. Ryan, OSP D. Eisenhut, NRR J! LIT Cummings, OIA H. K. Shapar, ELD SS Bldg R. Minogue, SD W. J. Dircks, NMSS S. Levine, RES PRELIMINARY NOTIFICATION 1447

$20

.