PNO-79-267:on 790719,Unit 2 Tripped from 50% Power on Low Steam Generator Level.Caused by Operator Leaning Against Control Panel Causing Main Feedwater Pump Turbine to Runback to Low Speed Stop
ML19256C892
Person / Time
Site: Arkansas Nuclear 
Issue date: 07/19/1979
From: Bryan S, Klingler G, Stone J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
References
PNO-79-267, NUDOCS 7910150687
Download: ML19256C892 (1)


Text

.~= %.

= :=:

. - = - - - - - -

+-

...m

.....-.m.

w 23r 2_-:= ;.-;n

. ?

.a c. ':.::r== _:=.~._. -..=_..=y-M - @ y-n:T "==*: ; = ~" ' - v - -

..s-::t-Y M -.-

-...: r 6 - -

.i i

~

.. -r.[t.. ; : -. Q.;;f== '-

..} =- -

. r_..

m.

P FTTMTNARY NOTIFICATION

==

July 19,1979

' FFrTwrMPJ NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-79-267 This prelwnarv notification constitutes EARLY notice of an event of POSSIPTT safety or nublic interest significance.

The information presented is as initially received without verification or evaluation and is basically all that is known by lE staff on this date.

TACILITY:

Arbncas Power and Light Company Arbnus Nuclear One (ANO), Unit 2 Russellville, Arkansas Locket No. 50-368 SITP.JiCT:

TRIP OF ANO UNIT 2 FROM 50% POWER At 1:20 a.m. hours on July 19, 1979, ANO Unit 2 tripped fron 50% power on low steam generator level.

Subsequent investigation did not reveal any equipment malfunction The licensee has concluded that the low steam generator level resulted when an operator leaning against the control panel caused the Main Feedwater pump turbine o runback to the low speed stop. The emergency feedwater system (EFW) actuated en low stean generator level; however, t'ae steam driven EFW.pu=p tripped on over-rpe e d.

The operators found that water had collected in the steam supply line b : tween a trap and the inlet valves to the emergency feedwater pump turbine.

This line was blown down through a drain and the steam driven pump successfully started three times in sequence. The stean driven pu=p was declared operational and -he unit was critical at 5:45 a.m. and is returning to 50% power.

A press release is not planned by either the licensee or the regicn.

Eegion IV was initially notified of this event on July 19, 1979 by the IE Eesident Inspector.

Contact:

J. Stone, IE x28019; G. Klingler, IE x28019; S. Bryan, IE x28019 Dis tribution:

Transmitted E St Chai_~an Eendrie Commissioner Bradford S. J. Chilk, SECY Co==issioner Eennedy Co==issiocer Ahearne C. C. Ka= merer, CA Co~-'ssioner Gilinsky ACRS (For Distribution)

Transni ted:

MXHB P. Bldg <.15 V. Stello IE I..

V. Ges s ich, EDO E. R. Denton, NRR Re gion-- i,.

E. L. Ornstein, EDO R. C. DeYoung, NRR

-~

J. J. Fcochard, PA R. J. Mattson, h1R N. M. Haller,19A D. Vassallo, NRR (MAIL)

R. G. Ryan, OSP D. Eisenhut,IUiR J. J. Cnmings, 01A E. E. Shap ar, ELD SS Bldg R. Minogue, SD W. J. Dircks, NMSS S. Levine, PIS

_}f _.

PPFTT M ARY NOTIFICAi ON 1447 284

.