Confirms 790827 Telcon & 790829 Meeting.Reassessment of Available Data Necessary to Define Threshold in Terms of Fuel Enthalpy
ML19256C017
Person / Time
Issue date: 09/17/1979
From: Hoatson D
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
To: Meyer R
Office of Nuclear Reactor Regulation
References
RTR-REGGD-01.077, RTR-REGGD-1.077 NUDOCS 7910030577
Download: ML19256C017 (2)


Text

pR "f Goq UNITED STATES k

NUCLEAR REGULATORY COMMisslON

+,

g

>c p,

W ASHINGTON, D. C. 20555

\\,

/

see l i 1979

    • es*

~

MEMORANDUM FOR:

R. O. Meyer Reactor Fuels Section FROM:

D. A. Hoatson Fuel Behavior Research Branch

SUBJECT:

RIA ENERGY DEPOSITION The purpose of this memorandum is to confirm our telephone conversations of August 27, 1979, and the meeting with you on August 29, 1979, to discuss the issue of energy deposition in an RIA event.

EG&G had convened a coamittee to review the methods used at PBF for calibration of reactivity insertion accident (RIA) experiments. At the PBF management meeting on August 24, 1979, they discussed the status of their actions to respond to the committee recommendations.

In the course of their work, EG&G noted that there appeared to be a discrepancy between the data base used to derive the limits for RIA fuel damage and the way these limits were applieJ in Reg. Guide 1.77.

In essence, the threshold for severe fuel damage in an RIA was established in SPERT experiments at about 300 cal /gm total energy deposi-tion.

To provide some conservatism, a figure of 280 cal /gm was selected as the acceptance criterion.

Reg. Guide 1.77, however, refers to 280 cal /gm

" radial average fuel enthalpy." The difference between " total energy" and

" fuel enthalpy" is that heat transfer from the fuel is pctmitted under the latter term.

One reactor vendor calculates that the cnergy carried away by heat transfer is about 35% of the total energy.

If a vendor calculated energy depositions near the threshold using the " fuel enthalpy" definition, the

" total energy" deposition could exceed 300 cal /gm.

A reassessment of the available data is needed to define a threshold in terms of " fuel enthalpy." Future PBF RIA experiments may provide better information of this kind.

It is our understanding that CPB plans to take the necessary actions to resolve the inconsistency between the Reg. Guide 1.77 position and the SPERT data on which it is ba nd.

$l Y &

D. A. Hoatson Fuel Behavior Research Branch Division of Reactor Safety Research cc:

See next page IE g o 3oS7 7 2zvL

5A R. O. Meyer SEP 171979 cc:

T. E. Murley, RSR L. S. Tong, RSR W. V. Johnston, RSR ti. Tokar, CPB R. W. Barber, DOE /HQ H. J.- Zeile, EG&G P. Mac Donald, EG&G Z. Martinson, EG&G PbR S. Levine, RES e