ML19256B742
| ML19256B742 | |
| Person / Time | |
|---|---|
| Site: | 05000199 |
| Issue date: | 08/10/1979 |
| From: | Grier B NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Koplik B MANHATTAN COLLEGE, RIVERDALE, NY |
| References | |
| NUDOCS 7908280265 | |
| Download: ML19256B742 (1) | |
Text
l&* **oug Q
y_
',o, UNITED STATES f y
,.f,-<
j NUCLEAR REGULATORY COMMISSION
% f';- 3
.. C REGION I o,',A g
631 PARK AVENUE V
,e KING OF PRUSSIA, PENNSYLVANIA 19406 August 10, 1979 Docket No. 50-199 Manhattan College Corporation ATTN:
Dr. Bernard Koplik, Chairman Mechanical Engineering Department Bronx, New York 10471 Gentlemen:
Enclosed is IE Bulletin No. 79-19, which requires action by you with regard to your reactor and/or facility (ies) with an ope.ating license.
Should you have questions regarding this Bulletin or the actions required of you, please contact this office.
Sincerely, ha f
cyce H. Grier Director
Enclosures:
1.
List of Bulletins Issued in Last Six Months cc w/encls:
Brother Gabriel Kane, Professor of Physics 7908280 2 6 g CP
=
ENCLOSURE 1 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 IE Bulletin No. 79-19 Date: August 10, 1979 Page 1 of 3 PACKAGING OF LOW-LEVEL RADI0 ACTIVE WASTE FOR TRANSPORT AND BURIAL Description of Circumstances:
Low-level radioactive waste is that waste which can be transferred and shipped to of three waste burial facilities which are located in and licensed by the Agr_ement States of Nevada, South Carolina, and Washington.
On July 10, 1979, the Governors of the three states notified NRC Chainnan Hendrie of the serious and repeated disregard for rules governing the shipments of low-level radioactive wastes to these burial facilities.
Examples of violations of Agreement State, D0T and NRC rules follow:
Improperly packaged uranium fines igniting packaged liquid scintillation vials in combustible waste is believed to have caused a fire and destruction of a truck at the Beatty, Nevada burial facility on May 14, 1979.
On July 2, 1979, three of twelve steel containers shipped to the Beatty burial facility were found to be leaking radioactive material.
The material was described on the bill of lading as being a solid inorganic salt (evaporator concentrates solidified with urea fonnaldehyde) from a reactor facility.
The Governor of the State of Nevada ordered the drums to be shipped out of the state and the burial facility was temporarily closed.
On July 30, the first - i,; ment into the reopened Beatty facility contained free liquid in " solid" material.
The radioactive contents were sand filters used at an insitu leaching process at a uranium mill.
Forty-three shipments with sixty-three m ficiencies were observed during the package inspection program between Aori' 10 and July 5 1979, by the Agreement State of South Carolina, at the Barnwe'l, S.C. burial facility.
The shipments were from reactor, medical, industrir.i and military facilities.
On June 28, 1979, the Federal Highway Administration issued a Notice of Violation to a reactor facility proposing a $10,000 fine for truck contamination resulting from improper closures on 55-gallon drums of LSA material and for im r
loading of the drums on the vehicle.
DUPLICATE DOCUMENT These are a few examples of shipmen which did not fully meet NRC, D0T a developed to protect the health and Entire document previously entere int ystem under:
three States with licensed burial f q
g c
is not rectified, they may have to i ANO /
(O U
three burial sites by violators.
q N o.
of pages:
/