Summary of 790501 Meeting W/Util Re SHOCK-O Computer Codes
ML19256B455
Person / Time
Site: Maine Yankee
Issue date: 05/23/1979
From: Nelson C
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 7907110219
Download: ML19256B455 (2)


Text

_

AR AEGO

/

o UNITED STATES l'

NUCLEAR REGULATORY COMMISSION 7

(

g WASHINGTON, D. C. 20555 p

k..... o f

May 23, 1979 Docket No. 50-309 LICENSEE:

Yankee Atomic Electric Ccmpany FACILITY: Maine Yankee Nuclear Power Station

SUBJECT:

SUMMARY

OF MEETING HELD ON MAY 1, 1979 REGARDING SHOCK 0 COMPUTER CODES During our meeting with the licensee on April 20, 1979, Stone and Webster (S&W) indicated that more than one version of the Shock 1 computer code may have been used at Maine Yankee. We met with the licensee and S&W on May 1, 1979 to discuss the versions of Shock 1.

A list of attendees is enclosed.

The licensee stated that three versions of Shock 1 (referred to as Shock 0) preceeded the version of Shock 1 previously identified with Maine Yankee.

These three versions of Shock 0 had been used for 70 Maine Yankee safety related piping analyses. No listings of these versions are available.

Seven comparative analyses were performed between Shock 0 and Shock 1.

The licensee stated that Shock 0 and Shock 1 were compatable, with results within FSAR allowables.

The licensee stated that Shock 0 - Shock 1 comparisons representing all three versions of Shock 0 should be completed by the end of the week and would be provided to the NRC staff. We requested that at least one comparison with NUPIPE-SW for each version of Shock 0 also be perfonned.

A Christian C. Nelson, Projec Manager Operating Reactors Branch #4 Division of Operating Reactors

Enclosure:

List of Attendees 836 192 7907110211' 9

Enclosure LIST OF ATTENDEES May 1.1979 YAEC NRC W. P. Johnson Chris Nelson J. R. Hoffman Steve Lewis Don Neighbors Joan Giannelli Steve Hosford Arnold Lee R. G. LaGrange Portland, ME - PRESS J. R. Fair

-Herald-P. J. Riehm Vince Noonan Gary Thomas D. Eisenhut 835 193