.t V. S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT REGION I Report No. 70-371/79-12 Docket No.70-371 License No. SNM-368 Safeguards Group 1 Category U_R Licensee:

United Nuclear Corporation 67 Sandy Desert Road Uncasville, Connecticut 06382 Facility Name:

UNC Naval Products Inspection W Uncasville, Connecticut Inspection Conducted:

June 19-22, 1979 Date of Last Physical Security Inspection Visit:

March 12-16, 1979 Type of Inspection:'

Unannounced Physical Security 4-

+2 o(

7-Y - 7 7 Inspectors:

R.

. Sheph rd, Physical Security Inspector date zu *L/

9-Y-7((

R. J Bailey, Phy,'sical Security Inspector date 7

^

date A

R

/2-i Approved by:

[If J.

. Devlin, Chief, Security and Investigation date

/

Section, Safeguards Branch Inspection Summary:

Areas Inspected:

Included review of Security Plan; Security Organization; Physical Barriers; Access Controls; Keys, Locks, Combinations; Detection Aids; Central Alarm and Communication System; Testing and Maintenance; SNM Protection; Records anc' Reports; and Reports of Incidents.

Followup on licensee's action on NRC's recer radations for improving the security program.

The inspection involved 50 inspector-hours onsite by two NRC inspectors.

The inspection was begun during the regular workshift period; 11 inspection-hours were accomplished during offshift periods.

Results:

The licensee was found to be in compliance with NRC requirements within the 12 areas examined during the inspection.

1283 205_