ML19254E521

From kanterella
Jump to navigation Jump to search
Discusses B&W-1564 Re Integrated Control Sys Reliability Analysis.Rept Is Responsive to Recommended long-term Requirements of Commission 790809 Order Re Restart
ML19254E521
Person / Time
Site: Crane 
Issue date: 10/26/1979
From: Herbein J
METROPOLITAN EDISON CO.
To: Vollmer R
NRC - TMI-2 OPERATIONS/SUPPORT TASK FORCE
References
E&L-1896, NUDOCS 7911010423
Download: ML19254E521 (1)


Text

Metropolitan Edison Company g

Post Office Box 542 Reading Pennsylvania 19640 215 929-3601 Writers Direct 0;al Number File:

2259.10 E&L-1896 October 26, 1979 Director of Nuclear Reactor Regulation ATTN:

R. H. Vollmer, Director Three Mile Island Support U. S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Mr. Vollmer:

SUBJECT:

THREE MILE ISLAND NUCLEAR STATICN UNIT 1 (TMI-1)

DOCKET NUMBER 50-289 OPERATING LICENSE NUMBER DPR-50 ICS RELIABILITY ANALYSIS The Babcock and Wilcox Company transmitted ten (10) copies of the subject analysis (B&W-1564) to the Nuclear Regulatory Commission by letter dated August 17, 1979. We have reviewed Babcock and Wilcox's analysis and ha';e concluded that it is applicable to TMI-1.

This Analysis is responsive to long term recommended requirement number one of the August 9, 1979 Commission order regarding TMI-l Restart.

Very truly yours,

)

/

J. G. Herbein Vice President - Nuclear Operations JGH/j ed cc:

R. W. Reid H. Silver 1281 03' S

7

\\

\\

7911010 @3 Metrccentan Easen Ccmcany :s a ?,'emce cf tre General %cnc Ut.',t es Sys:em