ML19254E224

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Discrepant Impact Test Results of Main Feedwater Piping Spools.Completion of Impact Retesting Delayed Due to Itt Grinnell Equipment Calibr Problems.Final Rept from Vendor Scheduled for 791119
ML19254E224
Person / Time
Site: Midland
Issue date: 10/22/1979
From:
BECHTEL GROUP, INC.
To:
Shared Package
ML19254E221 List:
References
HOWE-275-79, NUDOCS 7910310346
Download: ML19254E224 (1)


Text

.

Bechtel Associates f'rofessionalCorporation Attachment 1 I! owe-275-79

SUBJECT:

MCAR 29 (issued 8/31/79)

Impact Ter, tin ; of !!ain Feedwa ter Pipe INTER 1:1 REPORT 4 DATE: October 22, 1979 PROJECT: Consumers Power Company Midland Plant Units 1 6 2 Bechtel Job 7220 .

Status of Corrective Action and Investigation The status of actions in progress for resolution of the subject :: CAR is as follows.

,. 1) Bechtel h<s received confirmation from Crinne12 t'aut spool 1-r.u:-

,.. 2S-638-13-2, Register Nunber !!P-4-11, is being purchased and refnori-cated from ASME GA 333, Grade 6 material as previous)y stated in Int erin Report 3.

2) Grinnell has expericaced equipment calibration problems and has subcontracted the impact retesting of heat L-20479 at 701' The subcontractor has also experienced delays in complet.ing the required impact retesting. Grinnell, upon successful completion of the retesting, will submit an SD) 't as statti in Interim Report 3.

Because of the pending disposition of heat L-20479, the' reportable condition of pipo remains uncertain at this time.

Fotcast Data for Investication and Corrective Action The final report is scheduled for November 19, 1979.

/

Submitted by: f^ s.

[ ,// g j Approved by:

[jfr/d,g Concurrence by: jI g .,

~

DDI/j s ,

4 10/13/1

~5 035 7910810 3 t 6 .

' '~

. _..~_.. . . . .$ . .

.T