TENNESSEE VALLEY AUTHORITY CH ATTANCOGA. TENN ESSEE 37401 400 Chestnut Street Tower II October 22, 1979 Director of Nuclear Reactor Regulation Attention:

Mr.

L.

S. Rubenstein, Acting Chief Light Water Reactors Branch No. 4 Division of Project Management U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Mr. Rubenstein:

In the Matter of the Application

)

Docket Nos. 50-327 Tennessee Valley Authority

)

50-328 Enclosed is revision 8 to the "Preservice Baseline Inspection and Inservice Inspection Program for Tennessee Valley Authority Sequoyah Nuclear Plant."

The initial draft program was sub-mitted by J. E.

Gilleland's letter to S. A. Varga dated August 23, 1977.

As additional changes result from implementa-tion of the preservice program, they will be submitted.

Revision 8 incorporates inspection procedures related to the flaw indication found in the unit 1 reactor vessel closure head weld (refer to letter from L. M. Mills to S. A.

Varga dated July 10, 1979).

Very truly yours, TENNESSEE VALLEY AUTHORITY D-' \\ 'c L. M. Mills, Manager Nuclear Regulation and Safety Enclosure

^~0 343 6k s 1RREiiB

.~~..s6

.+%

..d