Form NRC418 U.S. NUCLEAR REGULATORY CoMMISSloN CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radioactive Materials Packages 1.(a) Certi e Number 1.(b) Revis n No.
1.(c) P e
n No.
1.(d) P es No. 1.(e) Tota No. Pages
- 2. PREAMBLE 2.(a)
This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
2.(c)
This certificate does not relieve the consignor from compliance with any requirerrmnt of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)
Frepared by (Name and address):
3.(b)
Title and identification of report or application:
Hittman Nuclear and Development Hittman Nuclear and Development applica-Corporation tion dated June 10, 1974, as supplemented.
9190 Red Branch Road Columbia, MD 21045 3.(c)
Docket No.
- 4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Description of Packaging and Authorized Contents. Model Number, Fissile Class, Other Conditions, and
References:
(a) Packaging (1) Model No.:
HN-200 (2) Description The packaging consists of a steel-lead-steel annulus cask fabricated in the form of a right circular cylinder and three different types of inner containers.
The shielded cask, closed at one end and a lid closure at the other, is 60.25 inches in diameter by 74.5 inches in height. The cask wall consists of a 3/8-inch inner steel shell, 3-3/4 inches of lead shielding, one inch outer steel shell, and a steel
~
flange connecting the two shells. The cask outer shell is surrounded by a one inch layer of insulating material and canned in 14-gauge steel.
The lid, sealed by a Viton 0-ring, is of similar construction and is bolted to t:1e cask body. A cylindrical shield plug is located in the center af the cask lid and is sealed by a Viton 0-ring.
Lifting and tie-down devices are attached to the cask body and impact skirts, consisting of removable rings of shock absorbing foam, are attached to the ends of the cask.
(3)
Drawing O 20}
The package is fabricated in accordance with the following Hittman Nuclear and Development Corp. Drawing No.:
C001-5-9200, Sheets 1 through 6, Revision I.
7910260 / cl[
Page 2 - Certificate No. 6574 - Revision No. 3 - Docket No. 71-6574 5.
(b) Contents (1) Type and form of material The package contents consist of large quantities of nonfissile radioactive wastes solids. These solids include spent ion exchange resins, filter sludges, evaporator concentrators and spent fuel cartridges.
(2) Maximum quantity of material per package The cask contents shall be contained within one of the following inner containers and limited as follows:
(a) A single disposable inner container consisting of a right circular steel cylinder with a positive leaktight closure cap at the top. A maximum decay heat load of 205 Btu /hr. The maximum loaded weight is 7,400 pounds.
(b) The HN-200-30 inner configuration consists of two tiers of four, 30-gallon D0T Specification 17H steel drums and two steel four-drum pallets. A maximum decay heat load of 84 Btu /hr. The maximum loaded weight is 5,050 pounds.
(c) The HN-200-55 inner configuration consists of one tier of three 55-gallon, D0T Specification 17H steel drums positioned on one steel pallet. A maximum decay heat load of 116 Btu /hr. The maximum load weight is 3,740 pounds.
6.
The total weight of the shipping container shall not exceed 47,000 pounds.
7.
Wooden battens shall be provideo in the shipping cask cavity sufficient to prevent significant movement of the contents relative to the shield plug under normal or accident conditions.
8.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
9.
Expiration date:
December 31, 1979.
8 282
Page 3 - Certificate No. 6574 - Revision No. 3 - Docket No. 71-6574 REFERENCES Hittman Nuclear and Development Corporation applicated dated June 10, 1974.
Supplements dtd: July 2 and October 10,1979.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
(
h Charles E. MacDonald, Chief
. )
Transportation Certification Branch Division of Fuel Cycle and Material Safety OCT 11 1979 Date:
8 283
.