Alabama Power Company 600 North 18th Street Post of* ice Box 2641 Birmingnam. Alabama 35291 Te:ephone 205 323-5341 A

kkJTc'e' 2ni AlabamaPower tM southern etw.trc system October 14, 1979 Director, N.R.R.

Nuclear Regulatory Ccratission Washington, D. C.

20555 Attention:

Mr. A. Scimwicer

Dear Mr. Schwencer:

Re: Farley Nuclear Plant Unit-1 (50-348)

Containment Purge Cort Evaluation As verbally requested by your staff, Alabama Power Cctnpany subnits the attached results of a cost analysis of various cases limiting containment purge at Farley Nuclear Plant, Unit-1.

Further information concerning operability of containment purge valves at Farley Nuclear Plant will be provided in the near future.

If you have any questions, please advise.

Yours very truly, h W0lM $

~

F. L. Clayton, Jr.'

FIfjr/TNE/mrb Attachment cc:

Mr. R. A. Thcx".as Mr. G. F. Trowbridge W s4s n9s 074 791occ 3 Y3 o

Y '*'

Cwr EvAuarIm RESUurS FOR LIMITING CONIAINENT PURGE Baseline: Unlimited availability of all purge systems.

CASE 1 : All purge is limited to 90 hours0.00104 days <br />0.025 hours <br />1.488095e-4 weeks <br />3.4245e-5 months <br /> per year in Modes 1, 2, 3 and 4.

CASE 2 : Unlimited mun-purge operation plus 90 hours0.00104 days <br />0.025 hours <br />1.488095e-4 weeks <br />3.4245e-5 months <br /> per year main purge operation in bbdes 1, 2, 3, and 4.

CASE 3 : All purgirg is limited to a fixed nurber of hours over 102 hours0.00118 days <br />0.0283 hours <br />1.686508e-4 weeks <br />3.8811e-5 months <br /> per year.

CASE 4 : Unlimited mini-purge plus no main purge operation in bbdes 1, 2, 3, and 4.

CASE 5 : No purging in blades 1 - 4.

MAIN PURGE HOURS REQUIRED WITH PIR7f COST DlTFEIEffIAL CASE IN 50 DES 1-4 (dollars / year) 1 102 1,063,000 2

19 106,600 3

102 1,058,200 4

0 220,400 5

0 1,433,200 OC G75 fJ U/-

O