Commonwealth Edison One First National Plan. Chicago. Ilknois X Address Reply to: Post Office Sox 767 Chicago, Illinois 60690 j
September 21, 1979 Mr. James G.
Keppler, Director Directorate of Inspection and Enforcement - Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137
Subject:
Zion Station Units 1 and 2 Response to IE Bulletin No. 79-21,
" Temperature Effects on Level Measurements" NRC Docket Nos. 50-295 and 50-304 Reference (a):
August 13, 1979 letter from James G.
Keppler to Byron Lee, Jr. transmitting IE Bulletin No. 79-21
Dear Mr. Keppler:
Reference (a) required Commonwealth Edison Company to take certain actions with regard to IE Bulletin No. 79-21,
" Temperature Effects on Level Measurements."
Attachment A to this letter contains Comm)nwealth Edison's response to this Bulletin.
Please address any questions that you might have concerning this matter to this office.
Very truly yours, D.
L.
Peoples Director of Nuclear Licensing WFN:mae attachment cc: