Text

{/C

~

O Northern Indiana Public Service Company mesco r-g General Ofbces l 5255 Hohman Avenue l Hammond. InJana 46325 l Tel 853 5200 (219)

EUGENE M. SHORB September 4, 1979

...., v c c n c s o r 1 Mr. James G. Keppler, Regional Director U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 RE: NRC IE Bulletin 79-03 dated March 12, 1979 Docket No. 50-367

Dear Mr. Keppler:

Northern Indiana Public Service Company's (NIPSCO) respons e dated May 9,1979, to IE Bulletin 79-03 dated March 12,19~9 con:1uded with the sentence, "If we are informed that General Electric plans for the Bailly facility call for the use of such materials, NIPSCO will notify you immediately." Mr. Shannon Phillips of Region III, contacted NIPSCO on July 17, 1979, suggesting that this statement created an open item which may not be closed out.

Accordingly NIPSCO made further inquiry of General Electric Company and was advised that Mr. W. R. Rutherford of the Bethesda office of the Nuclear Regulatory Commission was notified on May 14, 1979, by Mr. R. O. Brugge of General Electric,"...that no SA-312 piping manufactured by Youngstown Welding and Engineering Company has been used in GE-supplied piping systems for BWRs.

In addition, piping products ' welded without filler metal' are prohibited by our specifica-tions."

This supplement closes all open items and completes NIPSCO's response to all portions of IE Bulletin 79-03.

Very truly yours, X

EMS:bw cc:

U. S. Nuclear Regulatory Commission Office of Inspection & Enforcement Division of Reactor Construction Inspection Washington, D. C. 20555 7909270 8/O eg

,W 1044 215