WAt flOT CHLL K C ALIF OTINI A 9453G August 10, 1979 ALASKA, U N I V t H b i l, Y OF INSTITUTt. UF ANT _1C BIOLOGY 997h1
[ A lit b A N N O AK Gentlemen:
Enclosed is IE Bulletin l'o. 79-19 which requires action by you with regard to your l'RC license.
Should you have questions regardir.g this Bulletin or, the actions re-quired of you, please contact this office.
Sincerely,
)4N.mv.-
,{w R. H. Engelken Director
Enclosure:
IE Bulletin flo. 79-19 2 3 0
?!I 7909060]/g 4
Accession No:
7908070515 SSIf!S llo:
6820 UNITED STATES fluCLEAR REGULATORY COMf1ISSION OFFICE OF INSPECTION AND ENFORCE!!ENT WASHINGTON, D.C.
20555 August 10, 1979 IE Bulletin do. 79-19 PACKAGING OF LOW-LEVEL RADI0 ACTIVE WASTE FOR TRANSPORT AND BURIAL Description of Circunstances:
Low-level radioactive waste is that waste which can be transferred and shipped to one of three waste burial facilities which are locate 1 in and licensed by the Agreement States of Nevada, South Carolina, and Was'sington.
On July 10, 1979, the Governors of the three states notified NRC Chairnan Hendrie of the serious and repeated disrecard for rules covernino the shipments of low-level radioactive wastes to these burial facilities.
Examples of violations of Agreement State, DOT and NRC rules follow:
Improperly packaged uraniun fines igniting packaged liquid scintillation vials in combustible waste is believed to have caused a fire and destruction of a truck at the Beatty, Nevada burial facility on May 14, 1979.
On July 2,1979, three of twelve steel containers shipped to the Beatty burial facility were found to be leaking radioactive material.
The material vias described on the bill of lading as being a solid inoraanic salt (evaporator concentrates solidified with urea formaldehyde) from a reactor facility. The Governor of the State of Nevada ordered the drums to be shipped out of the state and the burial facility was temporarily closed.
On July 30, the first shipment into the reopened Beatty facility contained free liquid in " solid" material.
The radioactive contents were sand filters used at an insitu leaching process at a uranium mill.
Forty-three shipments with sixty-three deficiencies were observed during the package inspection program between April 10 and July 5,1979, by the Agreement State of South Carolina, at the Barnwell S.C. burial facility.
The shipments were from reactor, medical, industrial and military facilities.
On June 28, 1979, the Federal Highway Administration issued a Notice of Violation to a reactor facility proposing a $10,000 fine for truck contanina-tion resultinq from improper closures on 55-gallon drums of LSA material and for improper loading of the drums or ie vehicle.
These are a few examples of shipments 01 radioactive material to burial facilities which did not fully neet NRC, DOT and Agreement State requirements which were developed to protect the health and safety of the public. The Governors of the three States with licensed burial facilities have indicated that if the situation is not rectified, they may have to initiate actions which would deny use of the three burial sites violato
'IE Bulletin ?!o 79-19 August 10, 1979 Page 2 of 3 Sources of Information:
The 00T regulatory requirements can be found in 49 CFR Parts 170-179. The f!RC regulatory requirenents can be found in 10 CFR Parts 19 to 71. The NRC regu-latory requirements for Agreement State licensees in non-agreement states are in 10 CFR Part 150. Copies of the regulations may be purchased from the Superintendent of Documents, U. S. Governnent Printing Office, Washinaton, D.C. 20402.
Information about licensing requirements for flRC packages can be obtained from the ?iRC Trarsportaticn Franch (201 a27 a122).
Infermation about DDT packacing and transport requirements can be obtained by calling the DOT Office of H uardous fiaterials (202-426-2311).
Action To Be Taken By Licensees:
To assure the safe transfer, packaging, and transport of low-level radioactive waste, each licensee is expected to:
1.
liaintain a current set of D0T and ti?C regulations concerning the transfer, packaging and transport of low-level radioactive waste material.
2.
fiaintain a current set of requirements (license) placed on the waste burial firm by the Agreement State of Nevada, South Carolina, or WasHnqton before packaging low-level radioactive waste material for transfer and shipment to the Agreement State licensee.
If a waste collection contractor is used, obtain the appropriate requirements from the contractor.
3.
Designate, in writing, people in your oraanization who are responsible for the safe transfer, packaging and transport of low-level radioactive material.
4.
Provide management-approved, detailed instructions and operatin9 frocedures to all personnel involved in the transfer, packaging and transport of low-level radioactive material.
Special attention should be given to controls on the chemical and physical form of the low-level radioactive mater'al and on the containment integrity of the packaging.
5.
Provide trainina and periodic retraining in the DOT and NRC regulatory requirements, the waste burial license requirements, and in your instruc-tions and operating procedures for all personnel involved in the transfer, packaging and transport of radioactive material.
14aintain a record of training dates, attendees, and subject naterial for future inspections by NRC personnel.
6.
Provide trainina and periodic retraining to those employees who operate the processes which generate waste to assure that the volume of low-level radioactive waste is minimized and that such waste is processed into acceptable chenical and physical form for transfer and shipment to a low-level radioactive waste burial facility.
Q
, 14 0 3; ),
g> - {
</ J '
IE Bulletin flo. 79-19 Auoust 10, 1979 Page 3 of 3 7.
Establish and implenent a management-controlled audit function of all tranefer, packagina and transport activities to provide assurance that person?91, instructions and procedures, and proces; and transport equip-ment are functionina to ensure safety and compliance with regulatory requirements.
8.
Perform, within 60 days of the date of this bulletin, a management-control. led audit of your activities associated with the transfer, packaging and trans-port of low-level radioactive waste.
Maintain a record of all audits for future #aspectinr.s by !E cr DT inspectors.
(Note: If you have an estab-lished audit function and have performed such an audit of all activities in Items 1-6 within the past six months, this audit requirement is satisfied.)
9.
Report, in writing within 45 days, your plan of action and schedule with regard to the above itens.
In addition, provide responses to the three questions below.
Reports should be submitted to the Director of the appropriate flRC Regional Office and a copy should be forwarded to the flRC Office of Inspection and Enforcement, Division of Fuel Facility and fiaterials Safety Inspection, Washington, D.C.
20555.
Provide answers for 1978 and fo-the first six nonths of 1979 to the following questfor.s:
1.
How many low-level radioactive waste shipments did you nake? What was the volume of low-level radioactive waste shipped?
(Power reactor licensees who report this information in accordance with Technical Specifications do not need to respond to this question.)
2.
What was the quantity (curies) of low-level radioactive waste shipped? What were the major isotopes in the low-level radioactive waste?
(Power reactor licensees who report this information in accordance with Technical Specifications do not need to respond to this question.)
3.
Did you generate liquid low-level radioactive waste?
If the answer is 'yes,' what process was used to solidify the liquid waste?
Licensees who do not generate low-level radioactive waste should so indicate in their responses and do not need to take other actions specified in the above items.
Approved by GAO, B180225 (R0072); clearance expires 7-31-80.
Approval was given under a blanket clearance snecifically for identified generic problens.
ug
,9 4 772 2b a
-