Text
-
,
.
U.S. NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
REGION III
Report No. 50-305/79-18
Docket No. 50-305
License No. DPR-43
License:
Wisconsin Publice Service Corporation
Post Office Box 1200
Green Bay, WI 54305
Facility Name: Kewaunee Nuclear Power Plant
Inspection At:
Kewaunee Site, Kewaunee, Wisconsin
Inspection Conducted: October 15-19, 1979
Date of Last Phvsical Security Inspection-
April 23-27, 1979
Type of Inspection: Routine Unannounced Physical Protection
Inspectors:
I.
// Ad
9
Physical Security Specialist
/
'
E'A
. A. nh aa
n/2*/79
Physical Security Assistant
,
ksha
i ?.
) Safeguards Branch
( A. Ilin , Chief
// J [79'
Approved By:
Inspection Summary
Areas Inspected:
Included a review of (1) Security Plan; (2) Security
Program Audit; (3) Security Organization; (4) Protected Area Physical
Barriers; (5) Vital Area Physical Barriers; (6) Lighting (7) Access
Control (Identification, Authorization and Badging); (8) Access Control
(Search); (9) Accese Control (Escorting); (10) Access Control (Vital
Areas); (11) Alarm Stations; (12) Detection Aids; (13) Assessment Aids;
(14) Communications; (15) Testing and Maintenance; (16) Compensatory
Measures; (17) Power Supply; (18) Response; (19) Locks, Keys, and Combina-
tions; (20) Records and Reports; (21) Followup on Previous Items of
Noncompliance / Deviations; (22) Followup on Unresolved Items; (23) Followup
1537
162
n121 20
.
.
.
e
The inspection involved 90 inspector hours onsite by two NRC inspectors.
The inspection began during day shift period; 18 inspection hcurs were
accomplished during off shift periods.
Results- The Licensee was found to be in compliance with NRC require-
ments witiain the 21 areas examined during this inspection except for the
following three items:
1.
Security Organization - Some guards were not qualified in accordance
with commitments.
(Infraction)
2.
Access Controls (Search) - Some individuals were not adequately
searched.
(Repeat Infraction)
3.
Testing and Maintenance - Some security related equipment was not
tested in accordance with commitments.
(Deficiency)
Details (Part 2.790(d) Information)
1537
163
-2-