Notice of Violation from Insp on 790806-31
ML19253C489
Person / Time
Site: Sequoyah 
Issue date: 10/02/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19253C490 List:
References
50-327-79-46, NUDOCS 7912050625
Download: ML19253C489 (1)


Text

-

OCT 1 6 1975 APPENDIX A NOTICE OF VIOLATION Tennessee Valley Authority License No. CPPR-73 Sequoyah Unit 1 Based on the NRC inspection August 6-31, 1979, certain of your activities were apparently not conducted in full compliance with NRC requirera nts as indicated below. These items have been categorized as described in correspondence to you dated December 31, 1974.

As required by 10 CFR 50 Appendix B, Criterion V, activities affecting quality shall be accomplished in accordance with documented instructions.

The licensees accepted QA Program, FSAR Section 17.1A.5 states that activities effecting quality are prescribed by documented instructions in the form of drawings, specifications, and procedures.

Administrative Instruction AI-9, Temporary Alterations, which provides instructions for implementing this requirement, states that alterations will be properly documented and approved.

Contrary to the above, on August 31, 1979, a temporary alteration was identified on the control switch for FCV-30-8, a safety related containment purge isolation valve, which met none of the approval and documentation requirements of Administrative Instruction AI-9.

This is an infraction.

1504 067

[b 7912050