Text
.
..a ce '
UNITED STATES f /}.. '<<
ATOMIC ENERGY COMMISSION y,
W ASHINGTON. D.C.
20545
%,,,,,,,,,, }
r OCT 11 W2 Mr. James F. Mallay Manager, Licensing Babcock & Wilcox P. O. Box 1260 Lynchburg, Virginia 24505
Dear Mr. Mallay:
The regulatory staff has completed its review of Babcock & Wilcox Topical Report BAW-10013, dated December 1971, and entitled " Study of Intergranular Separations in Low Alloy Steel Heat-Affected Zones Under Austenitic Stainless Steel Weld Cladding" with revised pages 2-1, 2-2, 2-3, 5-3 and 5-4 dated February 15, 1972. A su= mary of our review is enclosed for your information.
As a result of our review we have concluded that Topical Report BAW-10013 as revised February 15, lo7%, will be acceptable by reference in applications for construction permits and operating licenses.
Sincerely, y ' '
J*,.
s g'l,
, l.! I,
R. C. DeYoung, Assistant Director for Pressurized Water Reactors Directorate of Licensing
Enclosure:
Topical Report Evaluation 1505 114
'911040 0 9