ML19253A986

From kanterella
Jump to navigation Jump to search
Forwards LER 79-033/03X-1
Date released: 09/24/2019 Download: ML19253A986


LER 79-033/03X-1:on 790524,during Plant Sys Review,Noted That Seismic Stress Analysis Not Performed for Reactor Bldg Cooling Sys Supply & Return Lines to Drywell Sump.Caused by Failure to Implement Procedural Instructions
ML19253A987
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 09/11/1979
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19253A987 (2)
Forwards LER 79-033/03X-1
ML19253A985
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 09/11/1979
From: Leonard J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19253A985 (1)