Amends 40 & 34 to Licenses DPR-42 & DPR-60,respectively, Adding Special Chlorination Program for Circulating Water Sys to Destroy Parasites in Sys
ML19250C476
Person / Time
Site: Prairie Island  
Issue date: 11/02/1979
From: Schwencer A
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19250C477 List:
References
NUDOCS 7911260264
Download: ML19250C476 (6)


Text

.

p* RE%

UNITED STATES y

fg NUCLEAR REGULATORY COMMISSION

+

g E

WASHINGTON D. C. 20555 E

oN...../

NORTHERN STATES POWER COMPANY DOCKET NO. 50-282 PRAIRIE ISLAND NUCLEAR GENERATING PLANT UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Arendment_No. 40 License No. DPR-42 1.

The Nuclear Regulatory Com1ission (the Commission) has found that:

A.

The application for amendment by Northern States Power Company (the licensee) dated October 30, 1979, complies with the standards and requirenents of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by tnis amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the cocinon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

1390 070 7911260 2[f

l,

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-42 is hereby amended to read as follows:

(2)

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 40, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

This license amendment is effective as of the date of its istuance.

3.

FOR THE NUCL AR REGULATORY COMMISSION l.j~

0 bW A. Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors

Attachment:

Changes to the Technical Specifications Date of Issuance:

November 2,1979 1390 071

g>R reg o

UNITED STATES g

g NUCLEAR REGULATORY COMMISSION

s>( 3 o

WASHINGTON, D. C. 20$55

%s NORTHERN STATES POWER COMPANY DOCKET NO. 50-306 PRAIRIE ISLAND NUCLEAR GENERATING PLANT UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 34 License No. DPR-60 1.

The Nuclear Regulatory Comission (the Comission) has found thati A.

The application for amendment by Northern States Power Company (the licensee) dated October 30, 1979, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with i0 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

1390 072

I 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-60 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 34,are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUC EAR REGULATORY COMMISSION A. Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors

Attachment:

Changes to the Technical Specifications Date of Issuance: November 2, 1979 1390 073

ATTACHMENT TO LICENSE AMENDMENTS AMENDMENT NO. 40 TO FACILITY OPERATING LICENSE NO. DPR-42 AMENDMENT N0. 34 TO FACILITY OPERATING LICENSE N0. DPR-60 DOCKET NOS. 50-282 AND 50-306 Revise Appendix B as follows:

Remove Page Insert Page B-6 B-6 1390 074

B-6 Soecification:

The cooling water system shall be chlorinated for not more than a total of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> per day. During chlorination periods, the total residual chlorine concentration at the outfall of the circulating water vsystem shall not exceed 0.05 ppm.

If chlorine treatmen't of the cooling water system is 30 minutes or less per day, the total residual chlorine concentration at the outfall shall not exceed 0.1 ppm.

Corrective action will be taken if the protection condition is exceeded.

If chlorination of other systems is necessary, the same standards apply.*

l Basis:

The circulating water system condensers are cleaned mechanically.

Nor= ally only the cooling water system is chlorinated. The protection conditions of this specification will provide protection of the aquatic biota in the receiving waters.

2.4.2 Corrosion Inhibitors and pH Control Agents Objective:

To avoid a significant deterioration in the river's water quality, by limiting the discharge of certain chemicals from the plant.

Specification:

The amount of certain che=1cals discharged to the river shall not exceed the following cumulative annual amounts as follows:

ammonia 3,300 lb/yr.

hydrazine 2,800 lb/yr.

morpholine.

700 lb/yr.

cyclohexylamine These chemicals are discharged at the outfall.

No other corrosion inhibitors shall be discharged.

~4hile re=aining within the above annual limits, daily blevdown discharge may vary as operations require, but under no conditions exceed a saximum of 30 pounds per day of a=monia at the outfall, with proportionately lower amounts of the other chemicals specified above.

If the stated daily or annual protection conditions are exceeded, correc:ive action will be taken.

Basis:

The only release of corrosion-inhibitor chemicals in plant operation is from the all volatile water chemistry trea:=ent (AVT) required for the steam-generator secondary water treatment system.

During nor=al full power opera: ion, the steam generator blowdown ficw is normally saintained at 120 gpm (total for both units).

Th is treatment is to be completed by December 31, 1979.

1390 075 Amendment no. 40, unit i Amendment No. 34, unit 2