CONNECTICUT YANKEE ATOMIC POWER COMPANY s
BERLIN, CO N N ECTIC U T P.O. BOX 270 H ARTFORD. CONNECTICUT 0610t Tatspuo=s 203 666 6:311 October 31, 1979 Docket No. 50-213 Director of Nuclear Reactor Regulation Attn:
Mr. D. L. Ziemann, Chief Operating Reactors Branch #2 U.
- o. Nuclear Regulatory Commission Washington, D. C.
20555
Reference:
(1)
W. G. Counsil letter to D. L. Ziemann dated October 27, 1978.
Gentlemen:
Haddam Neck Plant SEP Topic III-10.A In response to your verbal request for electrical schematic drawings for the Haddam Neck Plant to facilitate review of SEP Topic III-10.A, enclosed are aperture cards of the following drawings:
Dwg. #
Sheet #
Rev. #
Title (Electrical Schematics) 16103 - 32112 3
10 Elem. Diag. Switch Development 16103 - 32112 4
7 Elem. Diag. Switch Development 16103 - 32112 29 10 Elem. Diag. MOV's Auto Control 16103 - 32112 29A 2
MOV's 292B, 292C, Auto Controls Drawing 32112, Sheet 4 was specifically requested by the NRC.
Sheet 3 provides the motor operated valve (MOV) limit switch development also required. Please note that we are sending a new revision to Sheet 29 to reflect the removal from the drawing of two (2) previously listed valves now depicted on Sheet 29A, also included. The Staff is requested to dispose of the Sheet 29, Revision 9 aperture card forwarded to them in Reference (1).
We trust you find the enclosed material responsive to your verbal request.
Very truly yours, CONNECTICUT YANKEE ATOMIC POWER C ANY b
M W. G. Cous til
]9ffickhrhsident t
7 D1106 0 c1 O f