ML19250B841

From kanterella
Jump to navigation Jump to search
Responds to NRC 790927 Ltr Re Containment Purging & Venting W/Guidelines for Valve Operability During Normal Operation. Testing Scheduled to Begin 791029 & Will Be Performed by Allis Chalmers Corp.Test Procedure Encl
Date released: 09/21/2019 Download: ML19250B841


Six-Inch Butterfly Valve Air Tests.
ML19250B843
Person / Time
Site: Cooper Entergy icon.png
Issue date: 10/18/1979
From:
ALLIS-CHALMERS CORP.
To:
References
Download: ML19250B843 (5)
Responds to NRC 790927 Ltr Re Containment Purging & Venting W/Guidelines for Valve Operability During Normal Operation. Testing Scheduled to Begin 791029 & Will Be Performed by Allis Chalmers Corp.Test Procedure Encl
ML19250B840
Person / Time
Site: Cooper Entergy icon.png
Issue date: 10/26/1979
From: Pilant J
NEBRASKA PUBLIC POWER DISTRICT
To: EISENHUT D G
Office of Nuclear Reactor Regulation
References
Download: ML19250B840 (1)