a Form NRC 618 U.S. NUCLE AR REGUL ATORY COMMISSION

' 7 CERTIFICATE OF COMPLIANCE 10 FR For Radesc*ive Yaterials Pacuages IJa6 Certvicate Numeer 1.(b) Revis.on No.

1.lci Pacmage tdentification No.

1.(d ) Pages No 1.le) Total No. Pages 5341 3

USA /5341/Bf IF 1

7 2 3 REAM 8LE 2.la)

This cert.ficate is issued to satisf y Sections 173.393a.173.394.173 395. and 173.396 of the Deoartment of Transportation Hazaroovs Vaterials Regulations 149 CFR 170-189 and 14 CF R 1031 and Sections 146-19-10a and 146-19-100 of the Departrnent of Transoortation Cangerous C.argoes Regulations (46 CF R 146-143). as amendsj.

21b)

The packaging and contents described in item 5 below meets the safety standards set forth in Sudoart C of Title 10. Code of Federal Regulatens. Part 71. " Packaging of Radioactswo Yaterials for Transport and Transportation of Radioactive Vaterial Under Certain Conditions.'

2.lc)

This cerr ficate does not reheve the consignor from compliance with any recuirement of the regulations of the U.S. Cecartment of Transocrtation or other aopticaole regulatory agencies. including the governrnent of any count.Y tN ougn or into ahicn the oatkage will te transoorted.

3. TNs certificate is issued on the basis of a safety analysis report of the pacmaqa design or apodicatiort--

3 lal Precared by (Name and addressi:

3.(b )

Title are dentification of report or aposication:

The Babcock & Wilcox Company Babcock & Wilcox tipplication dated June 23, P. O. Box 785 1967, as supplemented Lynchburg, VA 24505 aac) oocket No.

71-3341 4 CONDITIONS TNs certdicate is conditonal upon the fi.ifilling of the recuirements of Sutoart O of 10 CF R 71, as apoticaole, and the conditions specified in item 5 oelow.

5 Cescription of Paciraging and Autnorized Cceitents. Model Nurnter, Fissile Class. Ctner Canditions, and Aef erences.

(a) Packaging (1) Model No.: NFP-55 (2) Description Packaging as cescribed and constructed in accordance with 00T Specifi-cation 6M except:

(i) the containment vessel is limited to a 5-inch Senedule 40 steel pipe,11 inches long, with threaded cap closure, (ii) the outside drwn must have at least 55-gallon capacity; and, (iii) tne sides and ends of the containment vessel must have at least 8 inches of insulation.

(b) Contents (1) Type and form of material Uranyl nitrate or uranium oxides, of any enrichment :n the U-235 isotope, provided the H/U-235 ratio does not exceed 20, considering all sources of moderation within the inner container.

(2) Maximum quantity of material per package Not more than 3.6 kilograms U-235 in a volume not to exceed 3.6 liters.

1204 054 moeuz4

~.

Page 2 - Certificate No. 5341 - Revision No. 3 - Docket No. 71-5341 5.

(c) Fissile Class II and III (1) Minimum number transport index to be shown on label for Class II 1.3 (2) Maximum number of packages per snipment for Class III 40 packages 6.

Pipe cap closure on both ends of Schedule 40 pipe to be sealed with teflon tape.

7.

The package authcrized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

8.

Expiraticn date: October 31, 1934.

1 REFERENCES The Babcock & Wilcox Company application dated June 23, 1967.

Supplement dated: January 5, 1970.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Charles E. MacDonald, Chief Transportation Certificacion Branch Division of Fael Cycle and Material Safety 007 0 9 G79 Date:

1204 055

.