Reactor Containment Bldg:Integrated Leak Rate Test, Apr 1977
Date released: 09/20/2019 Download: ML19249F133


Event Rept 76-19/3L on 760510:measured Leakage for Valves & Penetrations Exceeded Tech Specs Limits.Caused by Improper Welding of Seat Rings in Valves CA-V2 & CA-V5A.Seats/wedges of Rings Were Ground to Correct Scarred Surfaces
ML19249F136
Person / Time
Site: Crane 
Issue date: 06/09/1976
From: Arnold R
METROPOLITAN EDISON CO.
To:
References
Download: ML19249F136 (3)
Reactor Containment Bldg:Integrated Leak Rate Test, Apr 1977
ML19249F132
Person / Time
Site: Crane 
Issue date: 04/30/1977
From: Klingaman R, Shirk R
GILBERT/COMMONWEALTH, INC. (FORMERLY GILBERT ASSOCIAT, METROPOLITAN EDISON CO.
To:
References
Download: ML19249F132 (66)