Form NRC 618 U.S. NUCLE AR REGULATORY COMMISSICN I3 CERTIFICATE OF COMPLI ANCE M CFR For Radioactive Materials Packages 1.(a) Certificate Numter 1.(b l Revision No.

1.f cl Packaoe Identification No.

1.(d ) Pages No 1.le) Total No. Pages 5754 2

USA /5754/B( )F 1

2

2. PRE AMB LE 2.fal Tb** certificate is issued to satisf y Sections 173.333a.173.394.173.395. and 173 396 of the Cepartment of Transportation Hazardous Maiorials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-143), as amended.

2Ab)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Cade of Federal Regulations, Pwt 71, " Packaging of R.y1soactive Materials for Transport and Transportation of Radioactive Yatenal Under Certain Conditions /'

2.fc)

Thes certificato does not relieve the consignor from compiiance with any requirement of the regulations of the U.S. Copartment of Transportation or other applicable regulatory agencies includir g the government of any country through or into which the package will be transporte1.

3. This certificate is issued on the basis of a safety analysis report of the package desegn or application-31al Prepared by (Name and address):

3.(b)

Title and identification of report or application.

Nuclear Fuel Services, Inc.

Naclear Fuel Services, Inc. application P.O. Box 218 dated November 11, 1966, as supplemented.

Erwin, TN 37650 3.(c)

Docket No. 71-5754 4.

CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Sut:part O of 10 CF R 71, as applicable, and the conditions specified in item 5 below.

5. Description of Packagsng and Authorized Contents, Model Numeer, Fissile Class. Other Conditions, and References.

(a) Packaging (1) Model No.: RMG-172 (2) Description The containment vessel is a 6-inch ID by 4-1/4-inch long Schedule 40 steel pipe with a flanged and gasketed top closure. The containment vessel is centered and supported in a 16-inch ID by 21-14-inch long steel drum of minimum 24 gauge thickness by top and bottom stool sections.

(3) Drawing The container is constructed in accordance with Nuclear Fuel Services, Inc. Drawing No. RMG-172.

(b) Contents (1) Type and form of material Uranium metal or compounds which will withstand a temperature of 800 C without pressure generating decomposition. The uranium may be enriched to any degree in the U-235 isotope. The contents shall be contained within two, 750cc sealed metal cans.

~

~1081

',30

~

7010030s

.?

s c

Page 2 - Certificate No. 5754 - Revision No. 2 - Docket No. 71-5754 (2) Maximum quantity of material per package Ten (10) kilograms U-235, provided the total weight of the contents does not exceed twenty (20) kilograms.

(c) Fissile Class II Minimum transport index to be shown on label 4.5 6.

The top stool section shall be physically secured to maintain the internal spacing within the drum in the event the drum cover is lost.

7.

The package Suthorized by this certificate is hereby approved for use under the.ger.eral license provisions of 10 CFR 571.12(b).

8.

Expiration date:

September 30, 1984.

REFERENCES Nuclear Fuel Services, Inc. application dated November 11, 1966.

Supplement dated: October 11, 1967.

FOR hie U.S. NUCLEAR REGULATORY CCMMISSION d4IL Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety EE? 111973 Date:

lhb

)))

,