Form NRC 618 U.S. NUCLE AR REGULATORY COMMIS$10N

[c p ),

2 3 CERTIFICATE OF COMPLIANCE For Radioactive Materials f'ackages 1.tal Certificate Number 1.(b) Revision No.

1.(c) Package identification No.

1.(d) Pages No. 1.fe) Total No. Page*

5026 5

USA /5026/B( )

1 3

2. PRE AMBLE 2.(a)

This certificate is issued to sathfy Sections 173.393a.173.394,173.395 and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Capartment of Transportation Dangerous Cargoes Regulatioris 146 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety stattdards set forth in Subpart C of Title 10. Code of Federal Regu'ations. Part 71, " Packaging of Radioactive Materials for Tranport and Transportation of Radioactive MJterial Uncer Certain Om.ditions.

2.(c)

This certificMe does at relieve the consignor from ::ompliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies including the governmv.t of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of he package design or application-3.(a)

Prepared by (Narne and address):

3.fb)

T' rte and identification of report or applicatio Chem-Nuclear Systems, Inc.

ATCOR, Inc. Applica. ion dated February 7, 1974, P.O. Box 1866 as supplemented.

Bellevue, WA 98009 3.(c)

Docket No. 71-5026

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of hboart O of 10 CFR 71. as applicable, and the conditions specified in 1:em 5 bciow.
5. Description of Packaging and Authori: d Contents, Model Nurnber. Fimle Clas* Other Conditions. and References.

(a) Packaging (1) Model No.: BC-48-220 (2) Description The packaging is a steel-encased, concrete shielded shipping cask.

The cask is 94-1/4 inches in diameter by 103-3/4 inches in length.

Reinforced concrete occuoies the seven inch annular space between the shells and the two base plates.

The lid is a 4-3/4 inches thick laminated steel cover held in piace by thirty-two, high strength 1-1/4-inch diameter bolts.

A silicone 0-ring'is used to seal the joint between the lid and the cask body.

The outer shell and base plate are 1/4 inch thick, while inner shall and base plate are 2 inches thick. The cask is reinforced at the top and bottom with steel rings and is equipped with lifting lugs.

The lid is provided with two access ports. Gross weight is about 71,000 pounds.

(3) Drawings The package is constructed in accordance with the following ATCOR, Inc. Drawings Nos.:

1000-D-0049; 0146-B-0004, Rev. E; 0146-B-0009; 0146-0-0025, Rev. A; 0146-D-0020-1, Rev. A; and 0146-C-0018, Rev. E.

b 7910020 1C52 013

? age 2 - Certificate No. 5026 - Revision No. 5 - Docket No. 71-5026 (b) Contents (1) Type and form of material (i) Byproduct material in the form of solids and solidified waste contained within secondary contliner(s).

(ii) Radioactive material in the form of activated reactor components ;.ackaged in secondary containers.

(2) Maximum quantity of material per package Greater than Type A quantities of radioactive material, not to exceed 20 thermal watts and 23,000 pounds including weight of the contents, secondary container (s) and shoring.

6.

The dose rate from the loaded cask shall not exceed 10 mrem /hr at six feet from the surface of the cask.

7.

The access plugs shall be appropriately plugged and sealed prior to transport.

8.

Shoring shall be placed between the secondary container (s) and the cask cavity to prevent movement during normel and accident conditions of transport.

9.

Prior to each shipment, the packaging lid silicone 0-ring shall be inspected. The 3-ring shall be replaced with a new silicone 0-ring if inspection shows any defects or every six (6) months, whichever occurs first.

10. The package authorized by this ceri:ficate is hereby aporoved for use under the general license provisions of 10 CFR 571.12(b).
11. Expiration date:

December 31, 1979.

s 1052 014

Page 3 - Certificate No. 5026 - Revision No. 5 - Docket No. 71-5n26 REFERENCES ATCOR, Inc., application dated February 7, 1974.

Supplements dated: June 28 and July 29, 1974; Novembel-16,1977; and March 22,1978.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety SEP 0 51979 Date:

N W

1062 0i5