Recommends Section 4.4 of FSAR Be Accepted for Docketing. Info Re Loose Parts Monitoring Sys & Detailed Discussion of Operator Training Program Will Be Required to Complete Review
ML19249E493
Person / Time
Site: Grand Gulf  
Issue date: 06/20/1978
From: Ross D
Office of Nuclear Reactor Regulation
To: Vassallo D
Office of Nuclear Reactor Regulation
References
NUDOCS 7910010593
Download: ML19249E493 (1)


Text

l j

[IentralFDe N{26iTIO I

C lUfg7F'i1e l'.EMORAtiDU;l FOR:

D.B. Vassallo, Jr., Assistant Director for U!R's, DP:t FPO:f; D.F. Ross, Jr., Assistant Director for Reactor Safety, DSS

SUBJECT:

ACCEPTA!!CE REVIEW FOR CPAMD CULF !!UCLEAR STATION, U:llTS 1 A'iD 2 Plant !!ame: Grand Culf t'uclear Station, Units 1 and 2 Licensing Staga: Acceptance Revie.t Responsible Branch and Project l'anager: LHR-1, C. Thenas Rystens Safety Branch involved: Analysis Branch Revic'i Status: Conplete The Analysis Branch has reviewed Section 4.4 of the Grand Gulf FSAR and recomend that it be accepted for docketing. There is no description of a loose parts nonitoring system for Grand Gulf although there is a statment that General Electric is developing a vibration monitoring system for B'JR6. The following information and comittents relative to

...., _.,.... ; r. g.. H.g @, m rc q -E A.

The LPMS manufacturer's sensitivity specifications shall be provided.

The LPMS rust be operational and capable of recording vibration signals for a signatura analysis at the tine of initial start-up testing.

A description of the mittoring equipment including location and basis for alarm settingssshall be providad in the FSAR. Anticipated cajor sources of internal and external noise rust be provided along uith plans to uintuize these sources. A description of precautions taken to insure the operability of the LFHS after operational basis earth-1 quakes is required. A detailed discussion of the operator training progran for operation of the LPMS, planned operating procedures, and record keeping procederes is required.

i Urisiral o k3d U I '?,,

D. Y.T2:3 D.F. Ross, Jr., Assistant Director l

for Reactor Safety i

Division of Systems Safety cc:

S. !!anauer K. Kniel 773390267 R. l'attson Z. Rosztoczy J. Stolz L. Phillips C. Thomas

.W. liodges CO'4 TACT:

W. Hodges,flRR, 27588 T-!&ah--M

~

DSS:AM DSSfAfrh3DSS:AR S - RSO -

o.*

t

-x2 il Liy WHodges/w LPhillips.

ZRRosztoczy UFRoss--

.u-~..*

6/16/78 6/[(2/78 6/ \\G /78 6/[ h /78 o.*

NRC TORM 313 (9-76) NRCM 0240 h u. s. oov s am u rst e ma rirea cr ric ri s ers - ea s e:4 1032 h

7 810 010 Sf 3 A