ML19249B615

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 790618-22
ML19249B615
Person / Time
Site: Westinghouse
Issue date: 07/05/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19249B581 List:
References
70-1151-79-10, NUDOCS 7909040598
Download: ML19249B615 (1)


Text

JUL 0 51979 APPENDIX A NOTICE OF VIOLATION Westinghouse Electric Corporation License No. SNM-1107 Based on the NRC inspection June 18-22, 1979, certain of your activities were apparently not conducted in full compliance with NRC requirements as indicated below.

These items have been categorized as described in correspondence to you dated December 31, 1974.

As required by License Condition No. 45, written tests shall be conducted in determining the effectiveness of the training program.

Contrary te the above, the written test inadequate to determine the was effectiveness of the pertained to respirators and respiratory protection. training program in that ten of t The other two questions pertained to the hazards associated with breathing air contaminated with uranium and methods to reduce individuals' exposure.

The test failed to cover nuclear criticality safety and the various other areas of radiation protection which were covered in the training program.

This is a deficiency.

s)kq q k/ s /,-PW r,

.# s i 7 9 000 40 $yrg p9o90 4

.