Forwards LERs 79-060/03L-0,79-061/03L-0 & 79-062/03L-0
Date released: 09/20/2019 Download: ML19249B525


LER 79-062/03L-0:on 790804,failure of Full Length Control Element Assembly 39 to Move.Caused by Failed Control Element Assembly Enable Card.Card Replaced & Assembly Declared Operable within 1-h of Failure
ML19249B554
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/30/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19249B554 (1)
LER 79-061/03L-0:on 790804,failure of Low Pressure Nitrogen Supply in Reactor Bldg Penetration,Outside Isolation Valve, to Close on Control Signal.Caused by Limit Setpoint Drift. Limit Adjusted & Valve Returned to Svc
ML19249B536
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/30/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19249B536 (1)
LER 79-060/03L-0:on 790802,failure of Reactor Drain Tank 2T68 Discharge Reactor Bldg Penetration to Close from Control Signal.Caused by Crystallization of Boron in Vent on Valve Operator Piston.Valve Cleaned & Returned to Svc
ML19249B533
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/30/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19249B533 (1)
Forwards LERs 79-060/03L-0,79-061/03L-0 & 79-062/03L-0
ML19249B524
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/29/1979
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19249B524 (1)