Report No.
70-1151/79-9 Docket No. 70-1151 License No. ShT-1107 Safeguards Group No. III Licensee: Westinghouse Electric Corporation Nuclear Fuel Division Drawer R Columbia, South Carolina Facility Name: Westinghouse Electric Corporation inspection at Westinghouse Electric Corporation Dates of Last Material Control and Accounting Inspection Visit: April 24-27, 1979 Type of Inspection: Announced Materi 1 Control and Accounting
(// g!7 f Inspectors:
^
J. W. Bates, TMa 7,
4-23 and 31, 1979)
Date Signed L K (L o t/nhv 8
Date Signed f,21-23,1979)
E. E. Clay (Ma 14 T. f. J.A(
]
'A
+ ll4 q
ed
_ D Wilkins (May 14-18, 21-23, 1979) pate/
l ggf//
d 5 l'Y 7'l GJ A
..ayA 7-20, 1979 )
Date Si'gned A
.. /pt,A f*tHL.
b
/0 9
19/gned i'
Date e '(M i 21-23,ji979)
Rl'.g,at fp s 79 l
Jone
%7 1, 1 9)
Date Signed
/
./
Approved by:
v
. - /, h)_9 6-[/ 7 /77 F. P. Gillespie, ncting Section Chief thte 6igned Material ControI and Accountability Inspection Surmary Areas Inspected: This inspection involved 264 inspector-hours on site by five NEC inspectors and was begun during the regular hours.
'T2_ $.
Y!k Copy er cepte3 Pr es 7008170 @ y i
- Doce:r.: 1:., t to de reprodum d wit!!ut :yectri opprovalerIEi111 0
/
g,
,,T***"''~~,'u y..-.
T 1,'.'.TEl'1 TT."T'T' "EM C0'.1C.; 2.L; 1C,..EN
. Results: The licensee was found to be in compliance with KRC requirements in the one area examined during the inspection except for the following six items:
1.
Failure to make measurements of standards twice per week and the required replicates per material balance period.
2.
Failure to make measurements for items of SNM whose integrity has not been maintained by tamper-safing.
3.
Failure to verify seal integrity.
4.
Failure to maintain current tamper-safing, seal usage and disposal procedures.
5.
Failure to maintain control of access to tamper-safing devices.
6.
Failure te maintain records supporting seal disposal.
?
e 4
8 t
I..