Amend 10 to License NPF-5,temporarily Increasing Limiting Condition for Operation on Drywell Average Air Temp from 135 F to 145 F
ML19249A014
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 07/26/1979
From: Ippolito T
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19249A015 List:
References
NUDOCS 7908170561
Download: ML19249A014 (5)


Text

-

,ea arog UNITED STATES

.[ f)e(

h NUCLEAR REGULATORY COMMISSION W

,, g\\

- 3 WASHINGTON, D. C. 20555 o

e

\\; w,/

GEORGIA POWER COMPANY OGLETHORPE ELECTRIC MEMBERSHIP CORPORATION MUNICIPAL ELECTRIC ASSOCIATION OF GEORGIA CITY OF DALTON, GEORGIA DOCKET NO. 50-366 EDWIN I. HATCH NUCLEAR PLANT UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 10 License No. NPF-5 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Georgia Power Company, et al.

(the licensee) dated July 23, 1979, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; 8.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-5 is hereby amended 'o raad as follcws:

(2) Technical Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.10, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

700817002'I

135 *F*, reduce the average air l

temperature to within the limit witi. 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> anc in COLD SHUTDOWN within the follov:ing 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.1.7 The drywell average air temperature shall be the volumetric average of the temperatures at the following drywell elevations and shall be determined to be within the limit at least once per 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s:

,:inuth

}

Elevation a.

128-130 feet 115' cr 255*.c 3 5' or 320' E.

162 feet 90' or 210' c.

175 feet 90' or 270*

d.

187 feet 90* or 270*

  • From July 46,1979 until the end of the first refueling outage, a limit of 145 F applies.

t, O R 20 c,A

/

HATCH - UNIT 2 3/4 6-10 Amendment No. I,10