Provides Guidance & Funding to BNL Re Evaluations of Inservice Testing Programs for Operating Nuclear Power Plants.Requests Indication of DOE Acceptance of Guidance to BNL
ML19248D677
Person / Time
Issue date: 06/27/1979
From: Eisenhut D
Office of Nuclear Reactor Regulation
To: Bauer R
ENERGY, DEPT. OF
References
NUDOCS 7908170166
Download: ML19248D677 (6)


Text

'

1.

/

h 7-A, f

)

UNITED STATES y

'w/(gg NUCLEAR REGULATORY COMMISSION 5

E WASHINGTON, D. C. 20555 g * *v /,j 4

s JUN 2 71979 Mr. R. H. Bauer, Manager Chicago Operations Office U. S. Department of Energy 9800 South Cass Avenue Argonne, Illinois 60439

Dear Mr. Bauer:

This memorandum provides guidance and funding to BNL to support the Division of Operating Reactors for evaluations of Inservice Testing Programs for operating nuclear power plants.

The scope of this work and schedule are defined in the enclosure. The FY 1979 CH Financial Plan will include $200,000, an increase of $60,000 as of February 1,1979, for this work under B&R 2019 04 031, Fin A3117.

This additional funding will be made available by transferring $15,000 from BNL Fin A3106 and modifying FY 1979 CH Financial Plan to include an additional $45,000.

Bimonthly progress reports containing technical achievements and financial status should be sent to this office. provides an estimated schedule for completing IST reviews.

The D0R Technical contact for overall technical management of this program is Alan Wang, who can be reached at 301-492-7110.

The enclosed NRC Form 173, Standard Order for DOE Work, for $45,000 is hereby submitted in accordance with Section III.B.2 of the DOE /NRC Memorandum of Understanding of February 24, 1978.

Please indicate DOE acceptance by signing and returning the enclosed NRC Form 173 to the NRC Office of the Controller, Division of Accounting, with a copy to the office of NRR, Attention Triplett.

s f fg

. Eisen ut, 5ctin'g 1 rector Division of Operating Reactors Nuclear Reactor Regulation

>n

! }h L. U U 000170 y

E5 MiRo/E(

ENCLOSURE 1 SCOPE OF WORK Technical Assistance on Inservice Testing Prograns Review as required by 10 CFR 50.55 a(g).

BNL will provide technical assistance to the D0R staff in the review of Inservice Testing Program for pumps and valves as required by 10 CFR 50.55a(g).

The review will include the reivew of proposed and updated programs for the following power stations:

Connecticut Yankee Cooper Indian Point 2 San Onofre Three Mile Island Kewaunee Yr.;iKee Rowe Browns Ferry 1, 2, 3 fitzpatrick Arkansas Point Beach Vermont Yankee Pilgrim 1 The program objective is to provide recommendations to the staff's evaluation of the licensee's proposed and periodically updated inservice testing program to assure compliance with the regulations.

The scope of the work includes:

a)

Evaluating the technical basis for relief from ASME Section XI Code requirements taken by the licensee that are determined to be impractical for his facility.

b)

Provide input for round one questions which will be transmitted to the licensee to request additional information.

c)

Evaluating the licensce's responses and participating in meetings with the NRC and the licensee to resolve further differences. This may involve trips to the plant or the NRC to have meetings with the licensee.

d)

Pre 9are a written input to the Safety Evaluation Report on the pr(posed inservice testing programs.

e)

In addition to the technical review, BNL will assist the staff in clarifying governing documents, in responding to ACRS requests for information and by appearing at hearings.

=4

J C

MILESTONES

~

TASK DEC 78 MAR 79 JUN 79 Task I

1) Cooper
2) San Onofre
3) Three Mile Island
4) Kewaur,ee
5) Browns Ferry
6) Arkansas a

a) The SER's for the above are completed but need to be re-written in a different format.

Task 2

7) Connecticut Yankee h

a) Review IST submittal b)

IST review session with a

licensee a

c) Complete SER for IST

~

program Task 3 8)

Yankee Rowe a)

Review IST submittal a

b)

IST review session with licensee 2

c) Complete SER for IST program Task 4 9)

Indian Point 2 8

a)

Review IST submittal b)

IST review session with A

licensee

-A c)

Complete SER for IST program k ~-

203 s.

MILESTONES TASK DEC 78 MAR 79 JUN 79 l

l Task 5

10) Fitzpatrick a) Review IST submittal

-A b)

IST review session with a

licensee

^

c) Complete SER for IST program Task 6

11) Point Beach a) Review IST submittal

"6 b)

IST review session with A

licensee c) Complete SER for IST program Task 7

12) Vermont Yankee

^

a) Review IST submittal A

b)

IST review session with l

licensee

^

c) Complete SER for IST progr am l

Task 8 l

13)

Browns Ferry 2 a) Review IST submittal L

b)

IST review session with licensee

-A c) Complete SER for IST program Task 9 14)

Browns Ferry 3 a) Review IST submittal A

b)

IST review session with licensee c) Complete SER for IST

-- J program I

_t

'.n.

~/

,E

/U/

MILESTONES TASK DEC 78 MAR 79 JUNE 79 Task 10 15)

Pilgrim 1 a) Review IST submittal

-a b)

IST review session with A

licensee c) Complete SER for IST

-A program l

k I

'g

-l',

e.

NRC soRM 173 u S nucle AR RE GUL ATOR Y COMMISSION ORDE R NUMBE R (2 78)

OATE STANDARD ORDER FOR DOE WORK May 30, 1979 75 SUED TO. (DOE Office)

ISSUE D BY: (NRC Of f ecel ACCOUNTING CITATION

^""

""'"5"*

Office of Nuclear Reactor Chicago Operations Office Regulation 84 R NUMBE R PERFORMING ORG ANIZATION AND LOCATION 20-19-04-0301 FIN NUMBE R Brookhaven National Laboratory A-3117 woRxpERioo.rHiSORDER FIN TITLE FlXED 0 ESTIM ATED 0 FROM TO.

Inservice Testing Programs 10/1/78 9/30/79 GBLIG ATION AVAILABILITY PROVIDED BY:

A THIS ORDER S

45.000

~ B TOT AL OF ORDERS PL ACE D PRIOR TO THIS D AT E WITH THE PE RF OW91NG ORG ANIZ ATION UNDE R THE SAVE "APPROFRI AHON SYM90L" AND THE FIRST F OUF. OlGITS OF THE "B&R NUVRE R' CITE D ABOvs 140.000 C. TOTAL OLDERS TO DATE (TOTAL A & B) 185,000 0 AMOUNT in CLUDED IN "C" APPLICABLE 1O THE " fin NUMBE R" CITE D IN THIS OR DE R.

FINANCI AL FLEXIBILITY:

O FUNDS WILL NOT BE REPROGr,A**MED BETWEEN FINS LINE D CONSTITUTES A LIMITATION ON OBLIGATIONS

'AUTH O R ;Z E D.

O FUNDS MAY BE HEPT43F. AMMED NOT TO EXCEED 110% OF FIN LEVEL UP TO $50K. LINE C CONSTITUTES A LIMITATION ON OButGATIONS AL' THOR 1ZE D.

STANDARD TERMS AND CON 0;TIONS PROV'DED DOE ARE CONSIDERED PART OF THIS ORDER UNLESS OTHERWLSE NOTEO.

ATT/ CHME NTS THE FOLLOWING ATTA CHMENTS ARE HEREBY SECURITY:

MADE A PART OF THIS ORDER:

O WORK ON THIS ORDER IS NOT CLASSIFIED.

O STATEMENT OF WOR K O WORK ON THIS ORDER INVOLVES CLASSIFIED D ADDITION AL TERMS AND CONDITIONS INFORMATION. NRC FORM 187 IS ATTACHED.

O OTHER REMARKS:

  • Transfer $15,000 from A-3106 to A-3117 Topic Old Fin #

Old Funding New Funding Corrosion & Cooling A-3106 175K 160K Chemi stry ISI A-3117 140K 200K ISSUING AUTHORITY ACCEPTING ORGANIZATION SIGN A TUR E SIG N A T U RE TITLE TIT L E DATE NRCFORM 173 (2-78) o,,