Text
G E N E R A L @) E L E CT R I C NUCLEAR ENERGY PROJECTS DIVISION GENERAL ELECTRIC COMPANY.17s CURTNER AVE., SAN JOSE. CAUFORNIA 95125 MFft-191-79 MC 682 - (408)925-2744 July 27, 1979 U.S. Nuclear Regulatory Commission Division of Operating Reactors Office of fluclear Reactor Regulation Washington, D.C.
20555 Attention:
Dr. S.H. Hanauer Director of Unresolved Safety Issues
Subject:
ATWS GENERIC ANALYSIS FOR BWR/3 AND VERtiONT YANKEE
References:
- 1) Letter, R.J. Ma ttson to G.G. Sherwood, 2/15/79.
2)
Letter, D.L. Butcher to L.0. De1 George (Coninonwealth Edison Compcny), 7/16/79.
3)
Letter, G.H. Scott to '. 0. Mayer (Northern States Power Company), 7/lf 79.
4)
Letter, R.F. Thibai. t to G.C. Andognini (Boston Edison Company), 7/16/79.
- 5) Letter, R.F. Thibault to R. McGuinness (Northeast Utilities Service Company), 7/16/79.
6)
Letter, R.F. Thibault to W.F. Conway (Vermont Yankee Nuclear Power Corporation), /16/79.
In March 1979, the BWR/3 Owners and Ver nont Yankee requested General Electric to provide documentation, consistent wi'.h Reference (1) to serve as a basis for a rule to resolve the Anticipated Ti ansient Without Scram ( ATWS) issue.
The attached copies of the report " Assessment of BWR/3 Mark I Mitigation of ATWS in Response to NUREG 0460", (fiEDE 2 '669), provide an assessment of the ATWS mitigation capability for a typical 3WR/3 assuming NUREG 0460 Alternate
- 2 modi fications.
This work was performed under contract with the addressees given in Reference (2-6) and any questions should be addressed to the re-spective utilities.
Very truly yours,
//fi% i/c 6
&g R.H. Qu'chholz, Manager BWR Systems Licensing C
(fcPsp 790816094 5
c 7303/10
,1 -
.. _. _.....,.. -.. _... _ _ _.. - -