August 10, 1979 Docket tio. 50-433 Regents of the University of California c/o University of California, Santa Barbara Santa Barbara, California 93105 Attention:
R. J. Kroes Associate Vice Chancellor Gentlenen:
Enclosed is IE Bulletin No. 79-19 which requires action by you with regard to your reactor facility (ies) with an operating license.
Should you have questions regarding this Bulletin or the actions required of you, please contact this office.
Sincerely,
- , uqx,u.
- ~
~ E R. H. Engelken Director
Enclosures:
1.
IE Bulletin t;o. 79-19 2.
List of Bulletins !ssued in Last Six lionths (32f)2IO 7 908170C N
-. :s -.
Accession flo:
7908070515 SSIftS flo:
6820 UNITED STATES flVCLEAR REGULATORY COMt11SSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 August 10, 1979 IE Bulletin flo. 79-19 PACKAGIfiG 0F LOW-LEVEL RADI0 ACTIVE WASTE FOR TRANSPORT A!iD CURIAL Description of Circumstances:
Low-level radioactive waste is that waste which can be transferred and shipped to one of three waste burial facilities which are located in and licensed by the Agreement States of fievada, South Carolina, and Washington. On July 10, 1979, the Governors of the three states notified NRC Chaiman Hendrie of the serious and repeated disrecard for rules coverning the shipments of low-level radioactive wastes to these burial facilities.
Examples of violations of Agreement State, DOT and NRC rules follow:
Improperly packaged uraniun fines igniting packaged liquid scintillation vials in combustible waste is believed to have caused a fire and destruction of a truck at the Beatty, Nevada burial facility on May 14, 1979.
On July 2,1979, three of twelve steel containers shipped to the Beatty burial facility were found to be leaking radioactive material.
The material was described on the bill of lading as being a solid inorcanic salt (evaporator concentrates solidified with urea formaldehyde) from a reactor facility. The Governor of the State of Nevada ordered the drums to be shipped out of the state and the burial facility was temporarily closed.
On July 30, the first shipment into the reopened Beatty facility contained free liquid in " solid" material. The radioactive contents were sand filters used at an insitu leachinq process at a uranium mill.
Forty-three shipments with sixty-three deficiencies were observed during the package inspection program between April 10 and July 5,1979, by the Agreement State of South Carolina, at the Barnwell, S.C. burial facility. The shipnents were fron reactor, nedical, industrial and military facilities.
On June 28, 1979, the Federal Highway Administration issued a Notice of J M U in % or fruck contamina-f Violation to a reactor facility propos'
^ ~ ^
~'
tion resultinq from improper closures <
D PLICATE DOCUMENT for improper loading of the drums on tl g
n ed ument previously entered These are a few examples of shipments 1 to system under:
facilities which did not fully meet NR which were developed to protect the he ANo 7 h C [ h 7 h
/
/
Governors of the three States with lic 4
that if the situation is not rectified
/
N-f Pages:
C would deny use of the three burial sit U
fQQ jm
_-