Forwards QA Program Insp Rept 99900264/79-01 on 790507-11. No Noncompliance Noted
ML19247B504
Person / Time
Issue date: 05/25/1979
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Haggard K
DRAGON VALVES, INC.
Shared Package
ML19247B505 List:
References
REF-QA-99900264 NUDOCS 7908090183
Download: ML19247B504 (2)


Text

I a asog\\

.jn

/

UNITED STATES SY,er[%

NUCLEAR REGULATORY COMMISS!ON 5 [~~ " f,$

REGION IV 3,

f G11 RYAN PLAZA DRIVE, SUITE 1000

%.'.J [

ARLINGTON, TEXAS 76012 2 5 MAY 1979 Docket No. 99900264/79-01 Dragon Valves, Inc.

ATTN:

Mr. K. D. Haggard QA lbnager 13457 Excelsior Drive Norwalk, California 90650 Centlemen:

This refers to the QA Program inspection conducted by J. W. Sutton of this office on May 7-11, 1979, of your facility at Norwalk, California, associated with the manufacture of nuclear valves and to the discussion of our findings with you and Mr. H. C. Bond, President, at the conclusion of the inspection.

This inspection was =ade to confirm that, in the areas inspected, your QA Progra= is being ef fectively i=plemented. The inspection effort is not designed to assure that unique quality requirements imposed by a custom 7_r are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality. As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others.

You should therefore not conclude that the NRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective corrective action in response to their findings.

Areas examined during the inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examina-tion of procedures and representative records, interviews with personnel, and o~cservations by the inspector.

Within the scope of this inspection, we found no instance,here you failed to meet NRC requirements.

In accordance with Section 2.790 of the Commission's " Rules of Practice,"

Part 2, Titla 10, Code of Federal Regulations, a copy of this letter together with the er

,ed inspection report will be placed in the Commission's Public Document Rec If this report contains any information that you believe to be proprietary, it is necessary that you make a written application withia thirty (30) days to this office to withhold such information frca public disclosure. Any such application =ust include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and

,a 1

,I jU 7908090 y:f s

o

Dragon Valves, Inc.

2 should be prepared so that proprietary information identified in the applica-tion is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely,

\\A

,g Uldi otapovs, Ch e Vendor Inspection Branch

Enclosure:

Inspection Report No.

99900264/79-01

.O

\\,, 0

'y J'