e UMTl O STAlf s flUCLE An RECul,iTO Y ':0...*ls0lON WA3HIf.G T ON. D. C. M 3 May 14, 1979

+.....

MEMORA:'DUM FOR:

Edward S. Christenbury, Chief Hearing Counsel, OELD FROM:

D. B. Vassallo, Assistant Director for Light Water Reactors, Division of Project Management

SUBJECT:

BOARD f!0TIFICATION - Af1ALYSIS OF SINGLE R0D DROP EVE!!T -

WESTINGHOUSE PLAtlTS (Bil-79-18)

The enclosed staff memoranda which discuss a Westi'ghouse Part 21 notification regarding the analysis of the single rod drop accident relates to Westinghouse 3 loop plants.

North Anna is the only LWR three loop plant in the Board Notification time frame and I there-fore recommend that these memoranda be provided to the North Anna Board.

The Board should be aJvised that we will notify thern as soon as the final fix has been resolved.

l

.,,.w.

D. B. Vassallo, Assistant Director for Light Water Reactors Divisian of Project Management

Enclosures:

As stated cc:

H. Denton E. Case D. Eisenhut J. Davis, IE R. Boyd R. Mattson V. Stello R. DeYoung V. !!oore

.. Nichals Grimes u.

J. Stolz R. Baer

0. Parr S. Vprnn C,1" 488 277 700731067Jd

'