A/ A C PPk

  1. pa Mcg"k UNITED STATES E"

h NUCLEAR REGULATORY COMMISSION

'3'

$.}

j WASHINGTON, D. C. 20555 s

g p

JUN 141979 Mr. James 11. Taylor Manager, Licensing Babcock &,Wilcox Company Nuclear Power Generation P. O. Box 1260 lynchburg, Virgin'a 24505

Dear Mr. Taylor:

SUBJECT:

EVALUATION OF BAW-10120P We have completed our evaluation of Babcock & Wilcox Topical Report BAW-10120P,

" Comparison of Core Physics Calculations with Measurements." We have detemined that BAW-10120P is acceptable for reference to describe the techniques used to measure core physics parameters.

A summary of our evaluation is erclosed.

If our criteria or regulations change, such that our conclusions concerning BAW-10120P are invalidated, we will notify you and provide you with an opportunity to revise and, if you desire, Jesubmit this report for our review.

We request, that within three months, you issue a revised version of BAW-10120P and a non-proprietary version incorporating this letter and your responses to our requests for additional information.

In your letter of March 14, 1978, you requested that BAW-10120P be withheld from public disclosure pursuant to 10 CFR 2.790.

In support of this request, you submitted an affidavit with your letter of July 14, 1978, which contained statements as to the reasons for withholding this information from public disclosure.

We have reviewed your application and material based on the re-quirements and criteria of 10 CFR 2.790 and have determined that the above-mentioned document sought to be withheld contains trade secrets or confidential or privileged commercial or financial information. We also have found at this time that the right of the public to be fully apprised as to the bases for and effects of the proposed licensing actior, does not outweigh the demon-strated concern for protection of your competitive position. Accordingly, we have determined that the information should l'a withheld from public disclosure.

We therefore approve your request for withhclding pursuant to 10 CFR 2.790 and are withholding BAW-10120P from public inspection as proprietary.

Withholding from public inspection shall not affect the right, if any, of persons properly and directly concerned to inspect the documents.

If the 4oO 105 7 9073 3og7c

Mr. James H. Taylor JU'i 141979 need arises, we may send copies of this information to our consultants working in this area. We will, of course, cssure that the consultants have signed the appropriate agreements for handling proprietary data.

If the basis for withholding this information from public inspection should change in _the future such that the information could then be made available for public inspection, you should promptly notify the f4RC.

Sincerely, O

M NQ k.

bb

/ teven A. Yarga, Chief Light Water Reactors Bran flo. 4 Division of Project Management

Enclosure:

As stated cc:

Mr. Robert B. Borsum Babcock & Wilcox Company 7735 Old Georgetown Road Bethesda, Maryland 20014 490 106