ML19246C163

From kanterella
Jump to navigation Jump to search
Forwards LERs 79-082/03L-0 & 79-084/03L-0
Date released: 09/17/2019 Download: ML19246C163


LER 79-082/03L-0 on 790620:during Mode 1 Operation Steam Observed Leaking from Lagging of Trip Valve TV-MS111A. Caused by Steam Cuts on Seat Ring Gasket Surface.Surface Lapped & Gasket Set Replaced
ML19246C167
Person / Time
Site: North Anna Dominion icon.png
Issue date: 07/18/1979
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19246C167 (2)
LER 79-084/03L-0 on 790620:pressurizer Level Channel LT-1460 Declared Inoperable & Placed in Trip Condition.Caused by Energizing of Welding Machines in Penetration Area.Problem Cleared When Welding Machines Turned Off
ML19246C165
Person / Time
Site: North Anna Dominion icon.png
Issue date: 07/18/1979
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19246C165 (2)
Forwards LERs 79-082/03L-0 & 79-084/03L-0
ML19246C161
Person / Time
Site: North Anna Dominion icon.png
Issue date: 07/20/1979
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19246C161 (1)