ML19246C135

From kanterella
Jump to navigation Jump to search
Forwards LER 79-013/03L-0
Date released: 09/17/2019 Download: ML19246C135


LER 79-013/03L-0 on 790625:during Normal Operation,Hot Leg Temp Indications C/TI-122H Failed Low.Caused by Power Supply Failure Due to Blown Fuse.Ge/Mac Power Supply Model GR700 Replaced & Sys Returned to Normal
ML19246C143
Person / Time
Site: Fort Calhoun 
Issue date: 06/25/1979
From: Core M
OMAHA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19246C143 (3)
Forwards LER 79-013/03L-0
ML19246C134
Person / Time
Site: Fort Calhoun 
Issue date: 07/16/1979
From: Andrews R
OMAHA PUBLIC POWER DISTRICT
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19246C134 (1)