ML19242D504

From kanterella
Jump to navigation Jump to search
QA Program for License 50-17446-01
ML19242D504
Person / Time
Site: 07100131
Issue date: 05/25/1979
From: Lockman D
WELDING INSTITUTE OF ALASKA
To:
Shared Package
ML19242D500 List:
References
NUDOCS 7908150333
Download: ML19242D504 (4)


Text

l llCALIN ASSURANCE PROGRAM CF WELDING INSTITUTE OF ALASG Oame of Licensee) 50-17446-01

{

(L1 cense hu:r.cer) 1 l

FCR COMPLIANCE WITH 10 CFR PART 71 APPENDIX E 1.

Crnani:stion The final responsibility for the Guality Assurance (CA) Prcgram for Part 71 Requirements rests with Weldino Institute of Alaska Game of Licensee)

Cesign and Fabrication shall not be ccnducted under this CA Program.

TF.e CA Progra:r is imolemented as shcwn on the attached organization cha rt.

The Radiatio 1 Safety Officer is responsible for overall administration of the progra::1, training and certification, document control, and auditing.

l The Radicgraphers are responsible for handling, storing, shipping, inspection, test and operating status and record keeping.

2.

Quality Assurance Procram' The management of ' Welding Institute of Alaska f

(Licensee Name) establishes and implements this QA Program. Training, prior to engagement, fer all QA functions is required according to written procedures. GA Program revisions will be made according to written pro;edures with management aoproval. The CA Program will ensure that all defined CA procedures, engineering procedures, and specific.

provisions of the package design approval are satisfied. The CA Program will emphasize control of the characteristics of the package which are critical to safety.

The Ra41aticn Safety Officer shall assure that all radioactive material shiocing packages are designed and manufactured under a FA Prcgram a ; roved by Uclear Requiatory Comission for all packanes desirred I

cr f at:ricated after July 1,1373. This requirement can be satisfied by receiving a certification to this effect fract the manufacturer.

3.

Occument Cor col All documents related to a soecific shioping nackage will be controlled j

througn the use of written procedures. All document chances will be t

perforces according to written procedures approved by management.

I

.r.e Radiaticn Safety Officer shall insure that all CA fu.cti:ns are i

ccccutted in accordance with the latest a::plicable changes to these cccu:r.ents.

%g14 J f v

or->,

p #.A

_ps c

r Ga ra Industries F:r t e604-7%1-0012/79

_ _ _.. ~ _. _.. _ _. _.... _... _ _.. _. _. _

2114 Railroad A venue s

r Anchorage. Alaska 99501 e

1

~\\

(907) 276 3440 C. ti!1C 1RSiltute 0 h RS2G weu,y mee<u,

^

Inspectior. l Integrity l

G w

QUALITY ASSURANCE PROGRAM ORGANI7ATION CHART FOR I

WELDING INSTITUTE OF ALASKA

  1. 50-17446-01 FOR COMPLIANCE WITH 10 CFR PART 71, APPENDIX E i

l l

l t.

t I

j PR2SIDENT

'VICE PRESIDEN" "REASURER SECRE"ARY I j

l Vincent J.j j

Ernest A.

l A.

C.

Gordon E.

j s wa:. ;ing swalling smith

,oran

\\

i l

i l

t Tscxx: CAL X n.i n u.:. a l GINIRAL MANAG2R j

' & Radiation Safety Officer Richard J.

Schnaider Conald M.

Lockman i

907) 665 ^707

.(907) 243-4737

{

i I

i N.D.T.

PIR50NNZL (Radiographers)

I i

690258 o ydi,nhp?%-

g

,r,.m

.awm h.

Iv u

-~

.a 21 H Ra,iroad. I t e n ue

,. e e

e Anchorage,.I!aska 99501 CCElRC').RStitLG 0~ bRStG "Ed,Ude,au, Inspectwn lIntegray l

G QUALITY ASSURANCE PROGRAM ORGANIZATION CHART (Cont.)

FOR WELDING INSTITUTE OF ALASKA

  1. 50-17446-01 FOR COMPLIANCE WITH 10 CFR PART 71, APPENDIX E DESCRIPTION OF RESPONSIBILITY 1.

President, Vice President, Treasurer & Secretary - General management of tne company.

2.

General Manager - Responsible for operations control of the company, supervision of employees, cost control, job assignments, personnel relations, training.

3.

Radiation Safety Officer - Responsible for overall administration of the radiation safety program (including (Quality Assurance), personnel radiation safety training and certification, document control, and auditing of the radiation safety program.

4.

Radiograohers - Responsible for using, storing, shipping, inspection, testing, cperating status, and record keeping of radioisotope sources and devices in accord with written procedures of the company as approved by the Operations Manager and Radiation Safety Officer.

80259 E7dh

._-