Responds to IE Bulletin 79-02,Revision 1.Pipe Support Baseplate Flexibility Will Be accommodated,wedge-type Anchor Bolts Will Be Designed Using min-required Factor of Safety & Expansion Anchors Will Be Installed Per Qa/Qc Procedures
ML19242C993
Person / Time
Site: Bailly
Issue date: 07/06/1979
From: Shorb E
NORTHERN INDIANA PUBLIC SERVICE CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 7908140323
Download: ML19242C993 (3)


Text

.

R *. NWh'f A

Northern Indiami Public Service Company

~ NIPHCil g

General O%ces l 5265 Hohman Aven e l Hammond Indiana 46325 lTs' 853-5200 (219; u

EUGENE M SHORB r.

s, v.a o t s. c c.,,

July 6,1979 Mr. James G. Keppler U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Re:

NRC IE Bulletia 79-02 Revision 1 Dated 6-21-79

Dear Mr. Keppler:

In response to the IE Bulletin 79-02, Revision 1, Northern Indiana Public Service Company submits the following information:

Response to Item #1 The pipe support baseplate utilizing concrete expansion anchor bolts, for Bailly Generating Station - Nuclear 1 will be designed to accommodate baseplate flexibility. These designs will utilize wedge type expansion anchors ranging in diameter from 1/4 inch to 1 inch, with an embedment depth of 8 anchor diameters.

A non-linear finite element analysis of the expansion anchor plate assemblies will be performed utilizing a typical finite element model of a quarter section of a plate assembly. The concrete under the baseplate is represented by one-way (compression only) springs and the stiffness of these springs is computed on the basis of the elastic half-space approach. The anchors are represented by truss elements and the stiff-ness of the concrete expansion anchors are based upon an idealized load displacement curve. Pre-load in the concrete expansion anchors is simu-lated by an equivalent negative temperature load.

Due to the non-linear nature of the idealized load displacement curve, the plate assemblies are analyzed by the ultimate design approach in which the design loads are multiplied by a load factor equal to four. The j' c r]

o

  • 3 O

7908140ut agt 9 jg7g

ne enei.n. e umn.

. vs.. o.,ne.nu Mr. James G. Keppler Hammond, Indiana U. S. Nuclear Regulatory Commission July 6,1979

~~

Page Two resulting expansion anchor reactions are compared with the ultimate capa-city of the expansion anchors. The load factor equal to four was selected to be consistent with the minimum required factor of safety used in the rigid plate analysis.

Respense to Item G Wedge type anchor bolts will be specified and will be designed using a mini-mum factor of safety of four between bolt design load and the bolt ultimate ca pacity.

Response to Item #3 The dynamic / cyclic loads for which the pipe support baseplates will be designed will be obtained from a response spectra or time history method of analysis. These loads will be increased by a factor of 1. 5 to account for dynamic impact effects.

Presently, Northern Indiana Public Service Company intends on partici-pating with several utilities in a testing program to investigate the static, dynamic and relaxation characteristics of various types of concrete anchors. Participation in this test program is dependent on a satisfactory resolution of the pile driving matters presently before the Commission.

This testing program will be a comprehensive dynamic testing program under the direction of an independent testing laboratory to verify the dynamic behavior of wedge type expansion anchors. The results of the dynamic testing program will be available and reported to the NRC upon completion.

Response to Item #4 This question is not directly applicable to Northern Indiana Public Service Company inasmuch as no concrete nor concrete anchors have been installed, however, Northern Indiana Public Service Company expects to comply with the requisites of Item #4 by the exclusive use of wedge-type anchors with embedment depths equal to 8 anchor diameters in'all safety-related areas of Bailly Generating Station - Nuclear 1.

All concrete expansion anchors will be installed in accordance with approved QA/QC procedures.

These procedures will require, as a minimum, the verification of the 655 N3

...,$n.rn snoi.n. rum.nio m.rve. comp nu Mr. James G. Keppler Hammond, Indiana U. S. Nuclear Regulatory Commission July 6,1979

~~

Page Three following items:

a.

Installation torque b.

Test torque (measure of expansion anchor preload relaxation) c.

Embedment depth d.

Anchor size The testing program referenced in question 3 may require that additional Quality Control items be added to the above list.

Response to Item #5 Not applicable to Bailly Generating Station - Nuclear 1 as this item addresses those facilities with Operating Licenses.

Response to Item #6 Northern Indiana Public Service Company will maintain at the Bailly site all related Quality Assurance and Quality Control documentation required for the proper placement of the concrete expansion anchors on site and this documentation will be available for NRC inspection.

If any que stions are forthcoming, contact Mr. R. J. Bohn, (219) 787-8531, Ext. 205.