ML19242C970

From kanterella
Jump to navigation Jump to search
Value/Impact Statement on Amend of 10CFR34
ML19242C970
Person / Time
Issue date: 04/26/1979
From:
NRC OFFICE OF STANDARDS DEVELOPMENT
To:
Shared Package
ML19242C960 List:
References
SECY-79-294, NUDOCS 7908140277
Download: ML19242C970 (14)


Text

.

I

^

ENCLOSURE D g

4 Y

790814 o z77 o g>

no7, a

O O

e os-

'Ae

ENCLOSURE "0" VALUE/ IMPACT STATEMENT ON AMEN 0MENTS OF 10 CFR PART 34 This value/ impact statement first gives an overview of the radiation overexposure problem in industrial radiography.

Then the individual amendments of 10 CFR Part 34 are discussed.

Industrial radiography accounts for more than two-thirds of the nyerexposures reported by all NRC licensees greater than 5 rems to the whole body or 75 rems to the extremities and almost 90% of the over-exposures greater than 25 rems to the whole body and 375 rems to the extremities (Table 1).

Table 1.

Overexposures to externaI radiation reported by NRC licensees in the last 7 years 7otal Overexposures Overexposures greater Overexposures greater (1.25 or 3 rem whole than 5 rem whole body than 25 rem wnole body booy or 18.75 rem or 75 rem extremity or 375 rem extremity extremi tv)

All All All Year Licensees Radiography Licensees Radiograchy Licensees Radiography 1971 57 24 11 9

3 3

1972 59 21 12 6

3 3

1973 E5 24 12 7

2 2

1974 103 29 13 5

2 1

IS75 39 13 2

2 1

2 1976 52 20 14 14 4

4 1977 54 8

4 3

2 1

Total 429 139 (32%)

68 46 (68%)

17 15 (38%)

1 Enclosure "0" c 2 /,

090

These overexposures in Table 1 resulted in six cases of radiation burns on the hands, one case of which left a scar on a finger.

At the same time, the estimated total collective dose to tne industrial radiography worker population is less than one-half of that for power reactor personnel and abcut one-third of that for medical workers (Table 2).

Table 2.

Total radiation dose to workers in 1975 for licensees with the highest totals **

Number of Total dose workers with Average dose Type of Licen:ee (man-rems) measurable doses (rems)

Medical

  • 27,000 102,000 0.26 Power Reactors 21,270 28,034 0.76 INDUSTRIAL RADICCRAPHY" 9,300 15,500 0.60 "For both NRC and Agreement State licensees, estimated by multiplying NRC figures for total dose and number of workers by 2 for medical and by 3 for industrial radiography.

The number of workers reported for radiog-raphy exceeds the total number cf radiographers (estimated at 9000) because it includes persons monitored who were not radiographers (i.e., coworkers, super /isors, etc. )

xx Source:

" Occupational Radiation Excosure at NRC Licensed Facilities -

1975," Walter S. Cool, NUREG-0419,1978.

Data are based on voluntary reporting by licensees for 1975.

Such voluntary reporting was not requested for other years.

.n Y

f o

tn 2

Enclosure "D"

Likewise, the average radiation dose to workers is higher for five other categories of NRC-licensed workers than for radiographers (Table 3).

Table 3.

Average radiation dose to workers with measurable doses for licensees with the highest average deses - 1975**

Type of licensee Average dose (rems)

Unencapsulated 5NM 1.54 Waste disposal, burial 1.26 Power reactors 0.76 Fuel storage 0.69 Byproduct manufacture & distribution 0.64 Industrial Radiography 0.60 xxWalter S. Cool, op. cit.

Scme statements on the severity of the radiation overexposures experienced by NRC licensed industrial radiography since 1971,are in order:

1.

There have been no deaths, near-deaths, or illnesses due to acute effects of radiation in industrial radiograchy licensed by NRC.

The radiation overexposures excerienced have not been life threatening due to the acuta effects of radiatien.

3 Enclosure "D" 4 0 (;

1 O fi

,vv

2.

There has been no loss of limb due to extremity doses received in industrial radiography.

Since 1971 radiation burns on hands were visible in six instances.

In five cases the burns healed fully.

In one case there was a scar on a fingertip.

(Note, however, that there have been more severe cases among NRC licen-sees prior to 1971, among Agreement State licensees, and in foreign countries.) The conclusion is that while industrial radiography sources can, and occasionally have, caused serious injuries to extremities, there has been no loss of limb among NRC licensees over the last eight years (including 1978).

Few other industries can point to as little loss of limb, and many other industries have records which are very poor by comparison.

3.

Since the acute effects of radiography overexposures (i.e., loss of life or limb) are minimal the hazard of radiation overexposures to the whole body must be considered to be its effect in causing cancer or genetic defects much the same as radiation doses within regulatory limits.

Since overexposure incidents account for only a few percent of the total collec.tive dose received by radiograpners (about 100 ma,-rems / year vs. 3000 man-rems / year, they account for only a few percent of the risk from cancer or genetic defects.

With respect to total risk to all workers or average risk to a worker, industrial radiography presents less risk than some other classes of licensees (Tables 2 and 3).

f i -) '

of

..o 4

Enclosure "D"

The Nature of Radiograohy Overexoosures To estimate the value of the recommended amandments in terms of reducing overexposures, all reported radiography overexposures of greater thar. 5 rems whole body dose or 75 rems extremity dose for the years 1971 through 1977 were studied.

There were 46 people overexposed during those seven years in a total nf 42 overexposure incidents reported.

In four cases it was not possible to determine what happened; the discussion below concerns the other 38 incidents.

Radiography overexposure accidents generally happen in three parts.

First, the source is left exposed when it should not be.

Second, a required radiation survey to assure proper radiation levels is omitted or inade-quately done.

Third, the source is not secured in its shielded position.

In almost all devices the source securing mechanism cannot be operated if the source assembly is not in the shielded position.

All three of these failures are usually necessary for an overexposure to occur.

The reasons for the source being left exposed are shown in Table 4.

Table 4.

Reasons for source being exposed in 38 radiography overexposure incidents Radiographer forgets to retract source...........

7 Source jams in guid tuce.....................

7 Source disconnects from control cable.......

3 Radiogracher does not fully retract source into the s af e s hi e l ded p o s i tion................................

10 With two sources and controls present, the radiographer exposes the second source instead of retracting the first source.......................................

3 Source moves out of snielded position after survey......

3 Operator confuses "in" and " cut.

1 Otner miscellaneous..................................

4 5

Enclosure "0" b ' [.

1 (,.

It is interesting to look at the role of equipment failure.

The exposure devices involved in jammed sources were an Automation Industries 100A, Newport News I-30/NN250-1, Autcmation Industries 100, Technical Operations 533, Radionics PGO-30, Technical Operations 446, and an unknown model.

No pattern is evident.

The disconnects were with a Technical Operations 553, a Gamma Industries Century, and an Automation Industries (unknown model).

Again, no pattern is evident.

The situation of not fully retracted sources can be caused by operator error or by the source jamming or catching at the entrance of the device.

In four cases, a Technical Operations 533 was used; in one case, a Technical Operations 660; in one case, a Gamma Industries Century; in one case, a Simco-Testing DU-100P.

In three cases, no device model could be determined.

In none of these cases, however, was a device malfunction positively identified as a contributing factor in causing the source not to be fully retracted.

In summary, the malfunction rate of radiographic exposure devices is low, and no design defect leading to repeated overexposure incidents can be identified.

The secondary causes of overexposure are shown in Table 5.

By far the most prevalent cause is the failure of the radiographer to perform the survey after each exposure.

This survey is clearly recuired by s 34.43(b).

A variation of "no survey" is the incomplete survey where the radiogracher does not survey the front of the device or the guide tube.

)',

6 Enclosure "D"

Table 5.

Reasons that radiographers did not discover an exposed source in 28 overexposure incidents No survey performed.......................................

23 Incomplete survey............

5 Failure to lock device before moving.....................

3 Radiographer realized problem but did not handle the emergency situation properly.......................

3 Broken survey meter......................................

2 Other miscellaneous......................................

2 The amendments in Enclosure "A" of this paper are. discussed below primarily in terms of their value for reducing overexposures.

r t

A t%,

1J' 7

Enclosure "D"

AMEN 0 MENT 1 Statement:

Amend 5 34.11 to specify that the currently recuired licensee's internal inspection program would have to be conducted at intervals not to exceed three months and that records of the inspections would have to be kept for two years.

Comment:

It is current licensing practice not to issue radiography licenses unless the licensee commits to internal inspections at a minimum frequency of quarterly.

The licensee's flexibility in running its internal inspection program would be reduced.

A quarterly frequency might not be appropriate for the needs of all licensees.

For example, some licensees whose radiography is performed onsite now perform daily walk-throughs to check radiographer performance and do not produce written records sufficient to meet the requirements of the proposed regulation.

Thus, in those cases, the proposed regulation would add a burdenseme recordkeeping requirement.

Value:

Specifying a fixed frequency will reduce licensing correspond-ence on this matter.

Records of the inspection would be useful to both the licensee and to IE inspectors.

Imoact:

Most licensees now audit on a 3-month basis but a minority do not.

Thus, this rule would have no imcact for perhaps 80%-00% of licensees.

Scme of the others would have to conduct inspections more frequently, and some would be required to provide more dccumentation.

AFENDMENT 2 Statement:

Amend i 34.22 to require securing the scurce in its shielded position in each radicgrachic excosure cevice each time the source is returned to the shielcec cosition.

Comment:

Securing the source could prevent sucsequent personnel overexposure due to inadvertent movement of a source into an unshielded position after being retracted into its shielded position.

NMSS does not issue a license for radiogracny unless the applicant's cperating procedures provide for such security of tne source.

Securing tne source requires a few mcments of the radiogracner's time.

8 Enclosure "0"

, q :d i'

! l

Three of the 38 overexposure incidents can be directly attributed to a failure to lock the exposure device.

In addition to which if devices which could not be locked without the source being in the shielded position were

'd, the inability to lock the cevice would be a positive u

inuication that the source was not safely stored.

Value:

Securing the source would have directly prevented 3 of the 38 overexposure incidents.

In addition, in most of the other overexposure incidents, securing the source, which can be as s*mple as pushing down a lock mechanism or turning a knoo, would have provided the radiographer with a positive indication that the source was not in the safe shielded position.

Imcact:

Little.

Most licensees already secure the source routinely.

For others, the act would take only a few seconds of effort.

This would be negligible compared with the time the radiation survey takes.

AMENDMENT 3 Statement:

Amend 5 34.28 to require that radiographic exposure devices, storage containers, and source changers be checked for obvious damage each day before use and comprehensively inspected and maintained each quarter.

Ccement:

This amendment represents good practice in most situations.

A quarterly frequency is in agreement with most manufacturer's recommendations and with current licensing practice.

Specify-ing a fixed frequency reduces flexibility and quarterly maintenance would not be necessary in all cases.

A device used at moderate frequency in a clean laboratorj would need maintenance at a less frequent inter /al than one used under field conditions.

Also there is no good reason to perform maintenance on an exposure device that had not been used during the previous quarter.

In 4 instances in wnica the source jammed in the guide tuce an inspection of the device could have cisclosec an operating problem.

In the remaining 3 cases the guide tuce was kinked or damaged curing the operations.

Value:

Provide explicit statement of good cractice (daily eneck) and inspectable maintenance pr gram and assure that proolems are identifiec before tney occur.

Imcact:

Quarterly maintenance is fairly common practice.

Some additional maintenance would be recuirec.

9 Enclosure "0" c?6 100

AMENDMENT 4 Statement:

Add a new $ 34.29 and a definition in 6 34.2 to require that permanent radiographic installations have an alarm that would warn anyone entering the high radiation area that entry is being attempted while the source is exposed.

Comment:

Thirteen of the 46 people overexposed were overexposed in permanent installations.

In 3 instances an alarm device had been installed and was either ignored or disconnected.

This alarm requirement very likely would have prevented most of the other 10 overexposures.

Value:

Effective reduction in the number of overexposures in permanent radiographic installations.

Imoact:

$1,000 to $2,000 per installation, including installation costs, plus $100/yr to test and maintain.

Many installa-tions already have this alarm.

AMENDMENT 5 Statement:

Amend g 34.31 to require that both radiographers and radio-graphers' assistants demonstrate understanding of their train-ing by receiving written (or oral for assistants) and field examinations on the required subjects.

Comment:

Both written and field examinations are appropriate for demonstrating understanding of the required training by radiographers.

Value:

Provide a basis for determining the campetency of radiog-raphers and their assistants and for an inspectable record of training.

Imoact:

Almost none.

Records of tests are generally kept already.

AMEN 0 MENT 6 Statement:

Amend s 34.43 to stata that the pre ently required radia-tion surveys of radiographic exposu)e devices after each exposure include surveys of source guide tuces wnere readily accessible.

Comment:

A survey of the guide tube is an effective way to show that the source is in the shielded position.

Radiation levels at the radiographic exposure device can be near normal when the source is at the far end of the guide tube.

10 Enclosure "0"

,rp I

ibl

A very careful survey of the device itself including circling tt.a device fully and waiting for the meter to respond ccepletely, is also sufficient to estaclish that the source is in its fully shielded position.

Five over-exposures were caused because surveys were not complete enough to locate the source.

Value:

Explicit statement of good practice.

Imoact:

Small.

Operating procedures usually include such a survey.

AMENDMENT 7 Statement:

Add a new description of " personal supervision" to S 34.44 to require that a radiographer supervising an assistant must be physically present at the site where sealed sources are being used and watching the assistant when the assistant uses radiographic exposure devices, sealed sources or related source handling tools, or radiation survey instru-ments to determine that the source has returned to its shielded position following an exposure.

Ccmment:

In order to permit licensees to begin training individuals in the actual use of radiographic equipment at an early point in their training, the NRC staff requires minimal training to qualify as a radiographer's assistant.

Typically, a few hours of instruction are sufficient and the radiographer's assistant is qualified to do critical work only while being watched by the radiographer.

An assistant works in that capacity for a period of 3 to 6 months.

Assistants with months of experience may not always require this degree of supervision.

Value:

Mistakes due to inexperience could be avoided.

In 3 of the 38 overexposure incidents an improper retraction of a source or an imprcper survey of the exposure device by an unwatched assistant caused the overexposure.

Imcact:

Many of the licensees that use assistants new previde this degree of sucervisicn and tnis change would have little effect.

For the remaincer, this cnange wculd reduce the usefulness of assistants.

AMENOMENT 8 Statement:

Amend Accendix A of Part 34 to include stucy of typical radiograpny accidents which have occurred.

The NRC staff will provide suitable study material.

Also amend Appendix A to require training in any radicgraohic ecuipment inscection 11 Enclosure "D" 40<.0

1. a.,

vv

and maintenance that the radiographer will be required to perform.

Value:

If radiographers were aware of the mistakes that others have made they would be less likely to repeat these mistakes.

If a radiographer will be expected to inspect and maintain radiographic equipment, he should be trained to do 50.

Imoact:

Will add a couple of hours to the training of each radiographer.

CONCLUSIONS For the typical licensee the impact of these amendments should be quite small.

The amendments to some extent serve to codify what is already common practice in much of the industry and what the NRC generally requires by way of license condition.

In this respect the amendments should serve to make licensing easier for both the applicant and the NRC staff by making NP.C safety requirements more explicit.

Several of the amendments should improve safety.

Alarm requirements for permanent radiographic installations should improve safety at facili-ties not already having such alarms.

The requirement that management audits be conducted at a quarterly frequency should serve to increase management attention to safety at some companies where audits are conducted less fre-cuently.

The requirement describing surveys of excesure devices after radiographic exposures snould ucgrace survey precedures for scme licensees.

The increased sticervision required for radiographers' assistants should reduce the number of accidents involving inexperienced assistants.

The requirement to instruct radiograchers in accident case histories should help them avoid similar accidents.

12 Enclosure "D" bjb

The cost of these amendments to licensees should be minimal.

Many licensees would need to make no changes at all in their operations.

For oth rs the cost of upgrading their safety should not significantly affect the cost of their operations.

These amendments of Part 34 call for small but important changes in operating procedures.

l '1 (.

)\\0 13 Enclosure "D"

8 e

ENCLOSURE E D

d d

{

31I

,' ni

. ~. b ii

ENCLOSURE "E" RECOR0 KEEPING JUSTIFICATION ANALYSIS This analysis discusses recordkeeping requirements contained in amendments of 10 CFR Part 34 (Enclosure "A").

The analysis covers (1) need for the records, (2) cost to the licensee in maintaining the records, (3) alternatives to the recordkeeping, (4) value/ impact assessment of the recordkeeping, and (5) sources of information outside NRC.

The record-keeping requirements are discussed below by section of the regulations.

A.

Maintaining records of the licensee's quarterly internal inspection program required in 5 34.11.

(1) Need:

Section 34.11 requires licensees to perform a quarterly inspection or audit of the performance of their radiographers.

The purpose of the inspection is to make management assure that the radiographers are working safely.

It has been observed repeatedly that wnere licensee management does not monitor the safety performance of radiographers, they will have a high acci-dent rate.

ine records of the inspections will aid NRC inspectors in establishing that a genuine internal inscection was made.

The records will be used by the licensee to keep track of deficiencies that were uncovered so that they can be

)so\\ i-l' (

1 Enclosure "E"

corrected.

IE strongly stated that NRC inspectors require tnese records to determine that a bonafide internal inspection was made.

Records of past inspections will also be used by the licensee in his current inspections to make sure that previously noted deficiencies no longer exist.

(2) Cost:

A report on the radiographer's performance.aay take from C minutes, using a standard checklift, to one hour or mora if a report is written.

An ave. rage of 3C minutes per radiographe-is assumed.

At 4 times per year for an estimated 3000 radiographers, a total re:ordkeeping cost of 6000 man-hours is expected.

(3) Alternatives:

This is the only record on the performance of each individual radiographer.

Relying on memory to remamber the outcome of an internal inspection would not see:a adequate either to the licensae or to NRC inspectors.

A written record is also an effective means of informing upper management of the results of the intarnal inspection.

(4) Value/ impact assessment:

The records provide inspectable evicence that an important management function nas been perfor::ed.

They are t'1us very valuable in assuring that the interr.al inspections are done.

Maintaining a record of such an activity would accear to be well worth tne cost.

T' e records would also be valuaole to the licensee in performing emplo ee evaluations.

))',

2 Enclosure "E"

(5) Outside sources of information:

Ten of 49 public commenters discussed this amencment, but the co.,ments were primarily trat the proposed schedule was too restrictive.

No one expressed objectial to the recordkeeping requirement.

B.

Records showing that the licens e has performed a quarterly inspec-tion and maintenance of his radiography exposure devices as required in 5 34.28.

(1) Need:

This record is a simple log entry or a tag on a radio-graphic exposure device showing the last maintenance date.

The licensee needs these records to keep track of when each of his radiographic devices was last maintained.

The NRC inspector needs the records to aid in establishing that the devices are being maintained as required in 5 34.28.

(2) Cost:

This requires only noting the date of the maintenarce in a logbook or on a tag on the device.

It requires an estimated 5 minutds of time for each device 4 times a year.

For an esti-mated 2000 devices in use the recordkeeping burden becomes 1000 man-hours.

(3) Alternatives:

This is the cnly rrrord of maintenance of eacn exposure device.

Remembering maintenance dates of several pieces of equipment is imonssible for most people.

)'!

3 Enclosure "E"

(4) Value/ impact assessment:

The easiest way to know when a device was last maintained is to record the date of its last servicing.

This essential fact can be recorded at nominal cost.

There does not seem to be any easier way to know that the regulations are being met.

(5) Outside sources of information:

Two of 49 public commenters said this requirement involved too much recordkeeping.

C.

Records of quarterly tests on alarm interlock systems at permanent radiographic installations as required in 6 34.29.

(1) Need:

This record is a simple log entry or an entry on a chart at the permanent radiographic installation.

The licensee needs a record of when the alarm was last tested for his own use.

The NRC inspector needs the records to aid in establishing that the alarms are being maintained as required in 5 34.29.

(2) Cost:

This requires only a icg book entry or an entry on a chart.

The estimated time is 5 minutes per installation a times a year.

For the estimated 300 installations, the total record-keeping burden becomes 100 man-nours.

\\

,y, b

4 Enclosure "E"

(3) Alternatives:

This is the only record of the maintenance of the alarm.

The only way to be able to recall this date is to write it down in a suitable log or chart.

(4) Value/ impact assessment:

The easiest way to know when an alarm was last tested is to write down the date.

An essential fact is recorded at nominal cost.

(5) Outside sources of information:

None of the public commenters objected to keeping a record of this test.

D.

Records of the training of radiographers and radiographers' assistants in S 34.31.

(1) Need:

This record consists of filing a copy of the tasts a radiographer takes and keeping a record of refresher courses he attends.

The records will aid NRC inspectors in verifying that the radiographers have been trained adequately to meet the requirements of s 34.31 and the conditions of the license.

(2) Cost:

The cost of filing the tests taken and recording attend-ance at courses and lectures is estimated to be 5 minutes each once a year for 3000 radiographers.

The burden is therefore 250 man-hours per year.

52b llb 5

Enclosure "E"

(3) Alternatives:

In this case a viaole alternative might be for the NRC inspector to establish that adequate training has been given by relying solely on questions asked the radiographer about the training he received and testing his knowledge of important areas by asking him some questions on essential subjects.

An alternative for radiographers' assistants is not to require that records be kept since the records would prove so little.

(4) Value/ impact assessment:

Because of the minimal cost of 250 man-hours per year it does not seem unreasonable to ask that the records be maintained.

They provide a valuable resource in establishing how well a radiographer has been trained.

(5) Outside sources of information:

Two commenters thought assistant radiographers should be allowed to take oral examinations with records of the exam date maintained.

(This suggestion was adopted.) One comment said it should not be necessary to main-tain the records for as long as the pcrson was a radiogi,ner.

(The retention period was subsequently limited to 3 years.)

E.

Summary.

The total recordkeeping burden on licensees for these amencments is estimated to be 7350 man-hours per year.

6 Enclosure "E"

9 W

e e

g ENCLOSURE F d

u.

h.

I Y

a 6

-9 e

e a

r m

W 4 0 (-

]10 1U

~

ENCLOSURE "F" DRAFT LETTER TO CONGRESSIONAL COMMITTEES Enclosed for the information of the committee is a notice of amend-ments of 10 CFR Part 34 of the Nuclear Regulatory Ccmmission regulations dealing with industrial radiography.

The amendments would require several changes intended to improve radiography safety.

Other changes are intended to formalize current licensing practices as regulations.

A public announcement on thesre amendments to be released by the Ccm-mission in the next few days is also enclosed.

Enclosures:

1.

Federal Raciste_r Notice 2.

P'21ic Announcement

(, ' ' (,

i, l

1 Enclosure "F"

e e

g6-e

..e a

e

~

w S

_. ENCLOSURE G 9

W A

o w

1 w'

e p

"^ A, P

4 4

4 4

W

  • ~

e e

h L d r ri e

?._,.,t s o

Ja,.

wh.

.m

=

4 J

d

45 e

ENCLOSURE "G" STATUS OF ACTIONS DEALING WITH INDUSTRIAL RADIOGRAPHY A previous Commission Paper, SECY-78-57, " Reduction of Radiograpny Overexposures," discussed five staff actions that could potentially reduce the rate of overexposures among radiographers.

This paper would complete one of those actions-amendment of NRC regulations dealing with industrial radiography.

The status of the other four actions is given below.*

(1) Advance notice of proposed rulemaking on desian requirements for radioorachic exposure devices.

An advance notice of proposed rulemaking was published on March c7, 1978.

This notice was approved by the Commission following review of SECY-78-57.

Thirty-two public comments were received.

In addition, a public meeting on the proposed rules was held on April 18, 1978.

The public comments and the meeting revealed extensive divergence of opinion regarding the design requirements.

Agreement States expressed opposition to including detailed safety design criteria in the regulations and expressed preference for a regulatory guide in this area.

The staff agrees that the detailed design criteria should be x

In a memorandum dated March 20, 1979 (see Enclosure "H"), OPE suggested that this enclosure include the original as well as the nresent target dates.

This has been dore, although not all actions in SECY-78-57 pro-vided target dates.

1 'l l 1

Enclosure "G"

in a regulatory guide, although a brief amendment of the regu-lations seems necessary to provide a firm regulatory basis for the guide.

The staff plans to submit a recommendation to the Commission for such a rule change, accompanied with the draft guide, in late 1979.

The original target date for this action was late summer 1978.

The reason for the delay is that this work has'been given a lower priority than was initially assigned.

The staff has studied the overexposure incidents and is not aware ot d2 sign changes that would significantly decrease the rate of over-exposures, although this is not to say that work in this area would not be productive.

(2) Advisability of reouirina radiograohers to use audible alarm dosimeters.

The performance of audible alarm dosimeters, especially their reliability, has been studied by Battelle-Pacific Northwest Laboratories under contract with the NRC.

Their report indi-cates that certain models of audible alarm dosimeters would be adequately reliable for use by industrial radiographers, although their use would be subject to some limitations.

The Health Physics Society Standards Committee (liPSSC) has developed a draf t performance standard for these dosimeters.

The staff is developing a regulatory guide which will endorse the use of audible alarm dosimeters if they meet the draft HPSSC standard and are used within certain limitations.

The draft regulatory guide is scheduled 2

Enclosure "G"

. m >

b,,, (,;

i. L

to be issued in May, 1979.

SECY-78-57 did not provide a target date for the guide.

(3) Training procrams for radiographers.

The Office of Inspection and Enforcement has recently published a report containing case histories of radiography overexposure accidents (NUREG-0495).

The report was published in December, 1978 versus an August, 1978, target date.

Instruction in such case histories would be required by one of the amendments of 10 CFR Part 34 contained in Enclosure "A" of this paper.

The development of a standard safety training program for indus-trial radiographers is underway at the University of Lowell, under NRC contract.

The draft program was submitted to NRC in January,1979, meeting the original target date.

The NRC staff will review the program, and it will be revised as necessary.

The program will then be published as a draft NUREG report and distributed to radiography licensees and Agreement States for their review and comment.

An improved program, based on these comments, will be developed.

(4) Licensing of individual radiocrachers.

In a letter dated June 24, 1977, The Non Destructive Testing Management Association (NOTMA) suggested to the NRC staff that licensing of individual radiographers by the NRC would improve 3

Enclosure "G"

'ni<.b 3 ') )7 I l.

safety (1) by assuring a minimum level of competence and (2) by making the individual radiographer responsible for his own actions, making him liable for fines and suspension of his license for violations of NRC regulations and license conditions.

On June 28, 1978, the NDTMA asked NRC to consider their letter to be a petition for rulemaking.

The NRC accepted the letter as a petition.

A notice on the petition was published in the Federal Register on August 4, 1978, with public comments due by October 3, 1978.

Eleven public comments were received, all opposing the petition.

The staff is developing a recommended response to the petition which is scheduled to be submitted to the Commission by late 1979.

SECY-78-57 provided no target date for this action.

o s,.

4 Enclosure "G"